MUST

sunglowcitrineUrban and Civil

Nov 15, 2013 (3 years and 6 months ago)

313 views

Page
1

of
67


ميحرلا نمحرلا الله مسب

ع ش م مقر ءاطع
5

/
4

/
3

/

3103


جايتحا

ىنبملا

ديدجلا
)

ةعسوتلا
(


ىفشتسمل

ريملاا

مشاه

نب

نيسحلا

نم

ثاثلاا

يبطلا

ةزهجلااو

ددعلاو

ةيحارجلا


3102
/
4
/

04
خيرات دعب دري راسفتسا ياب رظني نل


item 1.

ELECTRICAL BED, ICU, with OVERBED TABLE and
BEDSIDE CABINET



Note: all three components must be from the same
manufacturer


A
: ICU Electric Bed.

Qty(22)



1.

It must be stated clearly in the original catalogue

that the offered
item is intended for critical care.

2.

Heavy
-
duty construction suitable for rugged use.

3.

The dimensions of the sleeping surface platform
to be a minimum
of

approximately
(
88
x

198) cm.

4.

The dimensions of the mattress
to be a minimum of

approxi
mately
(
90
x

210) cm.

5.

Configuration: Four sections.

6.

Bed extension.

7.

Fully electrical

8.

Battery back
-
up.

9.

Built
-
in electronic weighing scale must either be standard or
offered as an option.

10.

Siderails must incorporate embedded bed controls.

11.

Regular AC operation

must be independent of battery status.

12.

Electrically controlled manoeuvres must include:

a.

Up/down (range must be clearly specified)

b.

Trendelenburg / Reverse trendelenburg

c.

Backrest

d.

Full Fowler position

Page
2

of
67


13.

Easy release CPR control.

14.

Safe operational capacity
minimum of 225 kg.

15.

Four heavy
-
duty medical grade electro
-
conductive, non
-
marking
castors of not less than 15 cm diameter.

16.

Central brake system with steering function.

17.

Non
-
metallic side rails.

18.

Patient scale must be offered either as built
-
in or as optional.

19.

Radiolucent backrest.

20.

The bed should have separate controls for the patient and the
caregiver.

21.

Removable non
-
metallic Headboards and Footboards.

22.


All available colours for headboards and footboards must be
included in the offer.

23.


Four IV
-
pole receptacles

to be located each side of the bed which
can accommodate detachable IV
-
poles.

24.

Compatible IV poles with double hooks must be quoted in the
offer and priced separately.

25.

Height adjustment from
approximately

46 to
approximately

85
cm or a wider range.

26.

Four pr
otective revolving rubber bumpers located at each corner
of the bed.

27.

Drainage bag hooks located at each side of the bed.

28.

Medical grade foam mattress with the following features:

a.

Fire retardant

b.

Anti microbial

c.

Solution resistant

d.

Complete with non
-
latex
cover.

29.

Patient chart holder with heavy duty metallic paper clamp.

30.

Original Traction support

to be listed and priced separately.

31.

Original Lifting
-
pole

to be listed and priced separately

32.

All available options and accessories must be offered and priced
separa
tely.

33.


A list of standard accessories for the offered model (optional)
.






B
: Bedside Cabinet.

Qty(22)




1.

Standalone
.

2.

Heavy
-
duty and robust.

3.

Complete with a minimum of one drawer.

4.

Lower cabinet.

5.

Mounted on four heavy
-
duty castors.

Page
3

of
67


6.

Material, colour and design must be compatible with the beds and
all
available colours to be submitted with the offered.



C
:

Over
-
bed table.


Qty
(22)


1.

Standalone.

2.

Heavy
-
duty and robust.

3.

Mounted on four heavy
-
duty castors.

4.

Material, colour and design must be compatible with the beds and
all
available colours to be submitted with the offered.



item 2.

Wall
Suction Machine/low pressure


Qty(30)


a.

Wall mounted original bottles holder to hold two autoclavable jars
(≥ 1 litre each).

b.

Jars to be supplied with the unit.

c.

BOC straight connection for central suction lines with hose at last 2
meters long.


item 3.

Adult/ Paediatric Conventional ICU Ventilator with

Consumables

Qty(11)



A: ICU Ventilator:

General:

1.

Adult and paediatric application.

2.

Latest production that fulfils the required specs.

3.

Unit must come without any type of a compress
or.

4.

Microprocessor controlled.

5.

The unit must be mobile on a stand.

6.

Ergonomically designed.

7.

Castors of the mobile stand must be high quality medical
grade.

8.

Construction material must be robust and corrosion resistant.

9.

Maintenance
-
free
inspiratory/expiratory valves.

10.

Inspiratory flow, L/min to cover the range 6
-
150

11.

Surfaces must be flat, and easy to clean.

12.

Tidal Volume: to cover the range
20
-
2000 ml


Page
4

of
67


Ventilation:

The following modes and functions are required:

13.

Volume cycled.

14.

CMV.

15.

PEEP.

16.

Inverse I:E capability.

17.

Apnea back
-
up ventilation.



Monitored Parameters:

18.

Expiratory Time

19.

Expiratory Tidal volume.

20.

Expiratory minute volume.

21.

I:E ratio.

22.

Total breath rate.

23.

FiO2.

24.

Pressure data: Plateau / Mean / Baseline.

Other features:

25.

Audible and visual
adjustable alarms for monitored
parameters.

26.

Complete with oxygen and medical air hoses with BS type
probes.

27.

Battery backup for both settings and operation.



Required Accessories:

28.

Reusable adult and paediatric breathing circuit.

29.

Articulated flexible arm

for supporting the patient breathing
circuit.


B Consumables for
A:



1.

All the running requirements for system as recommended
by the manufacturer the including flow
-
sensors, oxygen
sensors, filters, any other cons
umables and maintenance
kits sufficient for 360 patients at a rate of a different
patient for every 24 hours for a period of 360 consecutive
days.

2.

Requirements must be listed in a clear and itemized manner
and prices fixed for 5 years from the date of
installation.


Page
5

of
67


item 4.

Infusion Pump


Qty(30)

1.

Compact design.

2.

A flow rate of at least 1 to 999 ml/hr.

3.

The pump should be an open system (major set suppliers) while
maintaining accuracy.

4.

Accuracy within 4% of displayed flow rate and volume.

5.

LCD display of flow and volume.

6.

Low battery warning.

7.

Infusion should be interrupted if battery is depleted.

8.

The pump should revert to keep vein open (KVO) when necessary.

9.

Adjustable alarm.

10.

The following alarms should be included:

a.

Up stream and down stream
occlusion.

b.

Malfunction alarms.

c.

Air bubble detector.

d.

Low battery alarm.

11.

Easy to transport and to clamp to a pole.

12.

Visible and clearly identified controls.

13.

Spill proof design.

A list of standard accessories


item 5.

Syringe pump





Qty. (
30

)

1.

Robust, compact
design.

2.

Easy to transport and to clamp to a standard IV pole.

3.

Protected against fluid spillage.

4.

Microprocessor controlled unit.

5.

Start up self
-
test capability with an error code system.

6.

Hygienic, flat touch control panel.

7.

Adjustable flow rate (increments of

0.1 ml/hr.).

8.

To accept syringe sizes of up to 60 ml from several well
-
known
manufacturers (open system).

9.

Settings and dose delivered should be retained to memory after
the unit is turned off.

10.

Adjustable alarm volume control that cannot be completely
turned off.

11.

Prime/purge control.

12.

Accuracy to within 5% of set flow rate.

13.

Clear and easy to read LCD display.

14.

Built
-
in high
-
capacity rechargeable battery.

15.

The following alarms should at least be included:

Page
6

of
67


a.

High
-
pressure / occlusion.

b.

System malfunction.

c.

Empty reservoir (including alarms for infusion near end and
infusion end).

d.

Syringe unlocked.

e.

Low battery alarm.

14.

A list of standard accessories for the offered model (optional).


item 6.

Air mattress





Qty. (
22

)


1.

A complete Air Mattress for ICU patients use wit
h air supply unit
to prevent bed sores.

2.

Full
-
length approx.200cm.

3.

Silent running compact air supply unit that can be attached to the
bed.

4.

Quick and smooth inflation and deflation with intermittent action.

5.

Patient weight capacity approximately 140 kg

6.

Easy

to clean smooth surface.

7.

Transport mode, mattress remains inflated during patient
transfer.

8.

Inflation valve to be included.

9.

A list of standard accessories for the offered model (optional).



item 7.

Portable Feeding pump

Qty. (
2

)

A heavy
-
duty, portable, microprocessor controlled enteral feeding pump
is required to accurately control the flow of liquid feeding solutions to
adult patients through
gastrostomy tubes
. The unit must meet or

surpass the following specifications:

1.

Compact, light
-
weight design.

2.

Durable, splash
-
proof exterior with easy to clean surfaces.

3.

Visible and clearly identified controls.

4.

Easy to transport and to clamp to standard IV poles.

5.

Built
-
in rechargeable battery
with operating time approximately ≥
24hr on full charge.

6.

Maximum flow rate approximately ≥ 400 ml/hr.

7.

Accuracy: 10% or better.

8.

Digital LCD display of rate, duration, delivered volume etc.

Page
7

of
67


9.

Parameters retained in memory: rate, volume, interval.
Parameters sh
ould be retained for at least approximately 24
hours.

10.

Audio
-
visual alarms:

a.

Occlusion.

b.

Malfunction alarms.

c.

Empty line.

d.

Low battery alarm.

11.

Compatible sets, enteral feeding tubes, and feeding formulas must
be available from
several

manufacturers.

12.

A list of s
tandard accessories for the offered model (optional).


B:

1.

Al
l the running requirements for (
A
)

including consumables
and maintenance kits sufficient for 360 patients for each
system over a perio
d of one year at a rate of use per day.

2.

Requirements must be listed in a clear and itemized manner
and prices fixed for 5 years from the date of installation.


item 8.

AED

Defibrillator






Qty. (
13
)


1.

Microprocessor controlled, biphasic technology
AED

Defibrillator

based system.

2.

LCD screen ≥ 4.5 inches.

3.

Synchronizer capability.

4.

Selected and delivered energy display (Digital readout).

5.

Charge/ discharge controls on main unit and paddles.

6.

Charging time to maximum energy level ≤ 8 seconds.

7.

Standard adult
paddles and built
-
in paediatric size.

8.

Full 3
-
lead ECG monitoring through leads or paddles.

9.

Variable heart rate Hi/ Low.

10.

Clear heart rate indicator.

11.

Variable beeper volume.

12.

Battery charging indicator and low battery indicator.

13.

Paddle contact integrity indic
ator.

14.

Large battery capacity (min. of 50 shocks at maximum setting).

15.

Self
-
test capability.

16.

Built
-
in annotative recorder with 25 mm
-
sec nominal speed.

17.

(3
-
5) Lead patient cable x2.

Page
8

of
67


18.

Original or local trolley. If a local trolley is offered, a sample must
be su
bmitted at DRMS for evaluation purposes. The purchasing
committee shall have the right to reject unsatisfactory samples,
and subsequently, the whole offer.

19.

A list of standard accessories for the offered model (optional).



item 9.

DRESSING CARTS

Qty (
20

)

This section describes the requirements for a Dressing Cart. In general,
this Dressing Cart should be designed to transport dressing supplies and
instruments. It shall have the following features:

1.

It shall not have sid
e panels.

2.

Approximate overall dimensions approximately (W x D x H):
900 x 450 x 900 mm with 4
-
leg frame construction

3.


Removable waste container

4.

Two utility drawers

5.

It shall be made completely of chrome
-
nickel alloy steel /
stainless steel or an equivalent

non
-
metallic material with high
quality finish to assure durability.

6.

It shall be corrosion resistant, disinfectant proof and easy to
clean.

7.

The cart should have a minimum of two removable shelves

8.

It shall be mounted on 4 castors with the following featur
es:

a.

Anti
-
static.

b.

Wear resistant.

c.

Approximate Diameter: approximately 75 mm.

d.

Swivel.



item 10.

Medication Carts


Qty (
16
)

This section describes the requirements for medication carts. In general,
medication carts should be designed with a locking mechanism for
secure drug storage and should be expressly designed to aid in
distributing medication on patient floors. Medication carts should
provide an efficient, mobile means of organizing medication and
supplies, such as cups and syringes, and transporting them to
the
patient.

Page
9

of
6
7


1.

The medication cart shall be a unit
-
dose cart with individual
drawers for each patient’s dosage.

2.

The medication cart should include a work surface.

3.

The medication cart should include storage wells and fenced sides.

4.

Approximately 30 drawers

5.

Lar
ge lower utility drawer(s)

6.

Dividers should be included.

7.

Master lock or locking mechanism that secures the entire cart and
that must be unlocked before any individual compartment can be
opened.

The following features and accessories should be included

8.

A pus
h handle.

9.

Non
-
marking and durable bumpers

10.

Waste container

11.

Medicine cup dispenser

12.

The cart shall be mobile on swivel caster with locks



item 11.

Portable patient monitor, preconfigured type

Qty. (
3

)




1.

User friendly.

2.

Portable type monitor

3.

Heavy duty with robust design.

4.

Two, Three lead ECG cable for each monitor.

5.

Adult, paediatric and neonatal cuffs must be quoted for

6.

Reusable adult and neonate SPO2 sensors for each monitor.

7.

Easy to mount on anaesthesia trolley upper shelf.

8.

All mounting
options to be offers including wall mount and
bench top.

9.

All leads, cables, sensors and accessories needed for
function must be stated clearly and priced separately.

10.

Standard accessory sets must be itemized.

11.

Adjustable ECG gain.

12.

Baseline adjustment capabil
ity.

13.

High resolution display with sweeping motion.

14.

All data shall be in real time (waveform and numeric).

15.

Large LCD screen (not less than 10.4 inches).

16.

Built
-
in rechargeable battery.

Page
10

of
67


17.

Where applicable, any software shall be of the latest
version, and any se
rvice / settings password must be
disclosed and perpetual.

18.

Vendors to list all prices of optional software and hardware
for offered system

19.

A list of standard accessories for the offered model
(optional)
.

item 12.

Heating Mattress

Qty.(
6
)


1.

Microprocessor controlled unit.

2.

Mobile unit with high quality castors.

3.

Robust design with heavy
-
duty construction.

4.

Air type with smooth quiet operation.

5.

Temperature range to be indicated clearly. Temperature range
will be an
important evaluation criterion in decision making.

6.

Digital temperature read
-
out for both set and measured values.

7.

Highest level of safety with alarm indicators.

8.

Mattresses to be made of high quality material that is easy to
clean and disinfect.



item 13.

TABLES, O
PERATING, GENERAL, ELECTRICAL

Qty (
6

)

1.

This section describes the requirements for a general operating
table. It shall meet or exceed the following
components/features:

2.

Electric, mobile operating table column.

3.

It shall have integrated, maintenance
-
free,
rechargeable
batteries with integrated battery

charger.

4.

4
-
section
(minimum) operating tabletop for general surgeries.

5.

Full function, corded hand pendant control (wireless [IR]
remote control to be offered as an

option).

6.

Approximate body weight load capacit
y:


2
50

Kg or better.

7.

The table shall meet or exceed the following specifications:

8.

Approximate total length of the operating tabletop with all of
its section:


2000 mm.

9.

Approximate tabletop width:


500 mm (550 mm with the
accessory side rails).

10.

Height:



700


1000 mm.

11.

Trendelenburg / reverse Trendelenburg:



25°.

12.

Lateral tilt: left / right:



15°.

Page
11

of
67


13.

Back plate: up / down:


40° / 40°.

14.

Leg plate downward:



90°.

15.

Side rails for attachment of accessories.

16.

Anesthesia screen with attachment clamp.

17.

Left and rig
ht arm rests with attachment clamps

18.

X
-
ray film arm.

19.

Complete orthopedic and traction attachments and
accessories.

20.

Holder/stand for storing accessories.

21.

All options and accessories shall be listed and quoted
separately.

22.

Accessories
MUST
be
priced separately

and

MUST

include at
least the following specialities: General, orthopaedics,
gynaecology, neurology, and urology.


item 14.

Anaesthesia Machine with Ventilator
.
Qty. (
6

)


The Unit

1.

High quality, high standard and heavy duty anaesthesia
machine suitable
for adults, paediatrics and neonates.

2.

Original cart to include:

a.

An upper shelf

b.


A working tray.

3.

Equipped with anti
-
static castors with brakes.

4.

The system must include a ventilator suitable for adults,
paediatrics and neonates.

5.

Ventilator brand must be the

same as the anaesthesia unit and
manufactured by the same company.

6.

The unit must include all necessary regulators and flow
-
meters

7.


Flow meters to include O
2
, N
2
O and medical air.

8.


Flow meters type must be specified.

9.

The system must contain a suction unit.

10.

Circulation system must be compact, sterilizable and
changeable from re
-
breathing (closed) to non re
-
breathing
(open).

11.

Central gas supply (Pipeline gas inlets) a number of three
inlets:

a.

O
2

b.

N
2
O

Page
12

of
67


c.

Medical Air (4 bar)

all with international colour code and pressure gauge according to
NIST system and
equipped with B.O.C probes

for connection to
central gas outlets.


12.

Gas cylinder yokes: (O
2

and N
2
O) with clear gas name marking
and pressure gauge equip
ped with international pin
-
index
system.


Vaporizers


13.

Vaporizes to be made by the same manufacturer of the offered
anaesthesia machine.

14.

Vaporizers to be selectatec type for fast and easy coupling.

15.

At least two vaporizers can be mounted on the machine at th
e
same time.

16.

Machine must be equipped with modern and new inhalation
agents’ vaporizers.

17.

Offered Vaporizes must include halothane, isoflurane and
sevofluorane.

18.

Vaporizers must be maintenance free.

19.


Halothane and isoflurane

vaporizers must be with key fil
ling,
Refilling adapters (keys) must be provided

20.

Sevofluorane
vaporizers must be with quick fill (easy fill)
system. Refilling adapters must be provided.

21.

O
2
/N
2
O safety control:


a.

Not less than 25% O
2
.

b.

Oxygen failure protection
device (hypoxic guarding

mechanism) with alarm.

22.

Oxygen
-
flush with a flow
-
rate not less than 30 litres/minute.

23.

Gas selector switch for 'no gases / full gases' (on/off gases
switch).

24.

Unit to include a CO
2
absorber with a capacity of
approximately 0.5 kg or more.


Ventilator

Page
13

of
67



25.

A mo
dern type ventilator with an integrated a microprocessor.

26.

Fully coloured LCD display.

27.

For ventilators using bellows, bellows type must be not other
than ascending or descending.

28.

Ventilation modes to be selectable and to include at least:

a.

Manual/Spontane
ous

b.

Pressure control

c.

Volume control

d.

PSV

e.

SIM

29.

Parameter readings of ventilator monitor to include not less
than:

a.

Airway pressure.

b.

Continuing pressure alarm.

c.

Expiratory volume/flow.

d.

Low pressure/apnea.

30.

Ventilator monitor graphic waveforms: to include volume
and
pressure.

31.

Type of sensor for Exp volume/ flow to be not other than hot
wire, galvanic cell or diff pressure.

32.

Coloured display monitor of not less than 8.4 inches in size.


Ventilators Technical Data


33.


Respiration frequency: 5
-

60 Bpm or better.

34.

Inspi
ration Flow: 5
-
70 l/min or a wider range.

35.

Tidal Volume: 20
-
1400 ml or a wider range.

36.

Maximum minute volume to be not less than 25 l / minute.

37.

I: E Ratio: 2:1 to 1:4 or better.

38.


Inspiratory pause: to include not less than the range 0
-
50%.

39.


Pressure
-
limit: 15


70 cmH
2
O or better.

40.

Ventilator to include an internal rechargeable battery of time
per charge not less than 30 minutes.


Alarms


Page
14

of
67


41.

Audible and visual alarms to include :

a.

Power failure alarm.

b.

Low/high pressure.

c.

Low O
2

concentration.

d.

Low
/high volume.

e.

O
2

inlet supply failure.

f.

Alarm interruption not more than one minute reset
function.

Accessories

42.

Reusable Open
-
type patient circuits for adults and paediatrics
(complete assembly).

43.

Reusable Closed
-
type patient circuit suitable for adults and
paediatrics.


44.

Offer must include a full gas

monitor with BIS module priced
separately as an option.

45.

Any other accessories must be listed and priced separately

46.

Complete with a full gas monitor either integrated or external.

A list of standard accessorie

item 15.

Mobile Infant Incubator




Qty. ( 2 )


1.

Microprocessor controlled servo type with self
-
test capability and
error code scheme.

2.

The option of a b
uilt
-
in electronic scale with clear di
gital display
and tare facility
must

be available and listed and priced
sep
arately.

3.

Servo oxygen option must be available and listed and priced
separately.

4.

Air mode and Skin mode temperature monitoring.

5.

Noise level ≤ ~ 50 dB, minimal vibration system.

6.

Double wall canopy.

7.

Electrically adjustable height.

8.

Integrated X
-
Ray tray.

9.

Integrated controlled humidification system.

10.

Flat, touch
-
type, hygienic, and liquid proof control panel.

11.

LCD or TFT display for the following parameters: temperatures
(air/ skin), oxygen concentration, humidity (actual and set for all
mentioned parameters
).

12.

Heat containment system to prevent sudden temperature
changes when an access door/port is opened.

Page
15

of
67


13.

Audio
-
visual alarm system with adjustable limits for:
temperatures, settings, indicators, main power, sensors …etc.

14.

Alarm mute with automatic reactivation.

15.

Micro intake filters.

16.

Large variable tilt mattress base with pullout mechanism.

17.

High quality, waterproof, easy to clean and disinfect mattress
(antibacterial and anti
-
fungal).

18.

Measurements and adjustments of temperatures shall be in
increments of 0.1
°
C.

19.

W
arm up time ~ 20 min or less.

20.

Temperature measurement accuracy ± 0.5° or better.

21.


At least 24hr trending capability.

22.

Large access doors on both sides.

23.

Hand ports: Two ports (front and back), one port (sides). At least
two ports must be equipped with durabl
e access sleeves.

24.

At least two tubing ports.

25.

Adequate storage drawer(s) and / or
Cabinet(s).

26.

At least one IV pole with two hooks.

27.

Medical grade antistatic, swivel type, non
-
marking castors with
brakes and a minimum diameter of 125mm.

28.

Two horizontal side ut
ility rails.

29.

A list of standard accessories for the offered model (optional)
.


item 16.

Chest Vibrator





Qty. (
4
)

1.

A massager/percussor is required.

2.

Variable speed range 20
-
50 cycles /second.

3.

Equipped with timer.

4.

Easy to store.

5.

Complete with a variety of
applicators.

6.

Mounted on heavy duty sturdy mobile stand.

Any accessories to be listed and priced separately


item 17.

IPPB Unit





Qty. (
4
)

Intermittent Positive Pressure Breathing respirator
is required

to
provide aerosol therapy

and a
ssisted pressure controlle
d inhalation
respiration for chronic pulmonary and bronchial disease.

The


1.

Air driven with pressure up to

~

40 mbar.

Page
16

of
67


2.

Reverse respiration system technique.

3.

Heated tubing system in the range of
~
30
-
35 °C.

4.

Respiration pressure range 5
-
40 mbar.

5.

Respiration flow range 10
-
50
l
/min.

6.

Micro aerosol nebulizer (mode to be specified as continuous or
intermittent).

7.

Trigger volume of approximately 8 m
l

or less.

8.

Built
-
in
Sound and vibration
insulated

air compressor.

9.

Compact, portable and light weight not to

exceed 6 Kg.

10.

Original stand to be offered separately.

11.

Complete set of basic accessories.

12.


Any other accessories must be listed and priced separately.


item 18.

Stools, adjustable, surgeon’s


Qty (
16

)



1.

Adjustable stool dedicated for
Surgeon’s.

2.

High
-
density foam rubber seat

3.

Full circle heel rest

4.

Electrically conductive, constructed of chrome nickel steel, or
equivalent.

5.

Hands free, foot operated hydraulic height control.

6.

Adjustable height: 45


60 cm approximately.

7.

It shall have an adj
ustable backrest.

8.

Mounted on 5 anti
-
static castors


item 19.

Modular Monitors with central station


Qty(35)

Specifications:


A:
Patient Monitor.




1.

User friendly.

2.

Heavy duty with robust design.

3.

Patient inputs to be defibrillator protected.

4.

Microprocessor controlled with noise rejection.

5.

Design: Modular and/or multi
-
parameter module and/or
smart
-
cable multi
-
parameter module and/or a combination of
single and multi
-
parameter modules.

6.

Parameters:

a.

ECG.

Page
17

of
67


b.

Respiration rate.

c.

NIBP.

d.

2xIBP (IBP+ CVP)

e.

Body temperature.

f.

SpO
2
.

g.

End tidal CO
2

(both mainstream and/or side stream
options to be offered).


7.

Original wall
-

mounting accessories.

8.

Each unit must come complete with the following:

a.

2x (3
-
leads) ECG and 2x (4 leads) ECG cables.

b.

Reusable SpO2 sensor 5x
(adult), 5x (Paediatric).

c.

1x (adult), 1x (paediatric) cuffs complete with hose.

d.

2x IBP kit with complete connection cables.

e.

2x temperature probes.

f.

2x CO
2

sensors (complete assembly).


9.

Adjustable ECG gain.

10.

Baseline adjustment capability.

11.

High resolution dis
play with sweeping motion.

12.

All data shall be in real time (waveform and numeric).

13.

High resolution colored LCD screen not less than 15".

14.

Where applicable, any software shall be of the latest version,
and any service / settings password must be disclosed and

perpetual.

15.

Vendors to list all prices of optional software and hardware for
offered system.

16.


Any other accessories including various patient cuff sizes must
be listed and priced separately.




B:
Central Station


The central station is to be located at the nurse station.

Bidders shall quote for a comprehensive offer including network.

Page
18

of
67


The local area network (LAN) must be designed so that the failure of
any bedside monitor does not affect the function or balance of

the
system.


item 1.

The central station monitor shall display waveforms
for the following parameters as obtained from each
individual bedside monitor:

a.

ECG.

b.

NIBP.

c.

IBP.

d.

Body temperature.

e.

SpO2.

f.

EtCO2.


item 2.

Central station monitor must be capable of displaying
data from

at least 15 monitors simultaneously.

item 3.

Flat easy to clean surfaces.

item 4.

Ability to display waveforms, numeric data, graphic
displays, tabular displays, and calculations.

item 5.

Software programmed touch keys for control of
monitor functions and display modes.

item 6.

Remote r
ecord initiation control for all waveforms.

item 7.

Control for waveform freeze.

item 8.

Audio / visual alarms with standard alarm /
acknowledge / reset control.

item 9.

Digital display of alarm limits and status.

item 10.

Memory for alarm events to provide a minimum of 10
seconds before
the event, and 15 seconds after the event.

item 11.

Selectable sweep speed for waveforms of 25 or 50
mm/sec for a display of at least 8 seconds of each
waveform.

item 12.

Alphanumeric data display for each parameter.

item 13.

High resolution LCD colored monitor minimum 19
inches.

item 14.

Mu
lti
-
channel strip
-
chart recorder with the following
features:

-


Thermal dot array.

-

Annotation of time, date, bed number, alarm status, and
vital signs.

Page
19

of
67


-

Paper speed selectable to be 25 or 50 mm/sec.

-

Paper width minimum 50 mm.

-

Automatic trace calibration and
centring.

-

Ability to stack and prioritize requests so that no alarm
information is lost.

-

Printer to allow for manual initiation from either the central
station or any bedside monitor.

item 15.

Clinical review software with the
following features:

-

Ability to support

all 15 bedside monitors.

-

Ability to store patient data for at least 48 hours.

-

Detailed analysis of waveforms.

-

Basic software must come as standard and to be included in


the main offer, while any optional software must be priced
separately.

-

Clinical

review software capable of generating full
documented report.


item 20.

Mayo Instrument Table



Qty (
14
)

1.

Constructed entirely from heavy
-
duty stainless steel

2.

Hydraulic Instrument Table.

3.

Removable stainless steel tray approx 600 x 400mm.

4.

Height and swivel bloc
king system

5.

Height adjustable from approx 850 up to 1450 mm or more.

6.

Antistatic castors with diameter of around 75mm (two with
brakes)

7.

Base to be T
-
shaped.




item 21.

Surgical
Suction Machine


Qty. (
10
)

A compact, light weight and heavy
-
duty
portable suction machine is
required to meet or surpass the following specifications:

1.

On/Off switch with light indicator.

2.

Maximum flow rate to be stated clearly.

3.

Maximum vacuum to be stated clearly.

Page
20

of
67


4.

Easy control of vacuum level through a knob or a switch
on the
control panel.

5.

Display of vacuum through a gauge that is easy to read with high
visibility mmHg and Kpa graduation.

6.

2x1 liter plexiglass reusable, and autoclavable jars, to be included
with the unit, with lids that provide secure seal and float
-
type

cut off
valve to prevent overflow.

7.

Bacteria filter to minimize cross infection.

8.

Silicon transparent tubes.

9.

Change
-
over valve to switch suction between jars.

10.

Splash proof design.

11.

Oil
-
free low noise pump.

12.

Any other accessories must be listed and priced
separately.


item 22.

IV solution Holder ( Ceiling type )

Qty(165)

1.

Entirely Made out stainless steel or aluminum

2.

4 hocks

3.

No plastic conection


item 23.


Instrument Cabinet




Qty. (
14
)


1.

Stainless steel construction.

2.

Doors to have a stainless
steel frame and glass sheets.

3.

Heavy duty handles with key lock.

4.

Inner stainless steel shelves with adjustable positions.



item 24.

Mobile Double
-
Bowl Stand



Qty. (
15

)

1.

Designed for use in the operation theatres.

2.

Made of high
-
quality

medical grade stainless steel.

3.

Removable bowl.

4.

Double
-
bowl stand design.

5.

Approximate capacity for bowl: 5 liters.

6.

Mounted on 5 antistatic, anti
-
scratch swivel castors

7.

It shall have a push handle
.


item 25.

KICK BUCKETS

Qty (
12

)

Page
21

of
67


This section describes the
requirements for a Kick Bucket. In general, this
Kick Bucket should be designed for use in the operating room.

1.

Constructed entirely from high quality stainless steel.

2.

Mounted on five castors

3.

Single bucket
.



item 26.

Conventional Electrosurgical Unit


Qty. (
6
)

1.

The
latest model of the offered range.

2.

Controls to include mono
-
polar and bipolar modes, pure cut,
blend cut, coagulate, and spray coagulation.

3.

Various cutting and coagulating handles and tips for mono
-
polar
and bipolar action.

4.

Protective circuit(s) that monit
ors continuity and hydration or
dehydration of the electrode that might affect safe return path for
the currents when operating in the mono
-
polar mode.

5.

Handle tips must be autoclavable.

6.

Reusable patient plate for adults and pediatrics.

7.

Reusable handles.

8.

Control through push buttons on handle, and through foot switch.

9.

Footswitch should be spill
-
proof.

10.

Flat control panel for all functions that is hygienic and easy
-
to
-
clean

by an LCD display
.

11.

Audible alarms with volume control and display of error cause.

12.

Or
iginal mobile trolley, with anti
-
static lockable castors.

13.

All types of hand
-
pieces and tips used in general surgery,
urosurgery, and neurosurgery to be quoted separately.

14.

A list of standard accessories for the offered model (optional).


item 27.

Step Ladder, Conductive



Qty (17)

1.

The conductive footstool shall have the following features:

2.

Constructed from stainless steel.

3.

Two steps

4.

It shall have an electrically conductive anti
-
slip rubber surface.

5.

It shall have
electrically conductive rubber feet.


item 28.

Electrical Drill / Saw




Qty. (
2

)

Control console with digital

display and alarm notification

Page
22

of
67



A. Drill:

1.

Electrical type with controlled speed regulation.

2.

Straight type hand
-
piece with quick action chuck.

3.

RPM ≈ 50,00
0 or higher.

4.

Autoclavable.

5.

Simple daily maintenance.

6.

Construction: stainless steel or aluminium.

7.

Footswitch for speed and direction control, with minimum 3
meter long electrical cord.

8.

Wire baskets with sterilizable basket holder.

9.

Oil Spray.


B. Oscillating

saws:

1.

Straight reciprocating electrical saw.

2.

Sagital saw mounted in 4
-
different positions or better.

3.

Construction: stainless steel or aluminium.

4.

Autoclavable.

5.

Simple daily maintenance.

6.

Length without blade to be specified.

7.

Saw blades different sizes and s
hapes.


All accessories including burrs and blades for drilling and cutting are to
be listed and priced separately.

1.

A list of standard accessories for the offered model (optional)
.



item 29.

Pneumatic Drill / Saw




Qty. (
2

)

1.

Lightweight, easy to control, and
provide minimal vibrations to the
user's hand.

2.

Handle should be ergonomically designed for extended single
-
hand usage.

3.

Safety locking mechanism on the trigger that prevents accidental
engagement when the saw is not in use.

4.

Detachable hose of sufficient len
gth that is lightweight and
flexible.

Page
23

of
67


5.

180º rotating head with several different incremental settings
allowing the user easier access angles for bone surgical
procedures.

6.

The seller shall specify whether lubrication is needed for optimal
performance.

7.

Chuck

should be commonly available and easy to replace.

8.

Bidders shall specify the type of chuck needed for the pneumatic
bone saw.

9.

Bone saw shall be made of stainless steel or aluminum.

10.

The seller shall specify whether the bone saw is capable of the
following c
onfiguration(s):

a.

Oscillation.

b.

Reciprocation.

c.

Sagital.

11.

Maximum speed should be specified.

12.

All blade positions and angles should be specified.

13.

Operating pressure
7

bars.

14.

Operated by compressed air.

15.

Required flow rate (liters per minute) of compressed air sho
uld be
specified.

16.

Bidders shall specify whether the following saw blade types are
available and list them as standard or optional:

a.

Straight

b.

Curved

c.

Angled, degree

17.

Bidders shall specify all sterilization or reprocessing methods that
may be used on the bone
saw.


Vendors

shall list any accessories (e.g., sterilization case, accessory trays,
and lubricating oil) that are available with the bone saw and specify
whether they are standard or optional.

2.

A list of standard accessories for the offered model (optional
)
.


item 30.

Hamper, Mobile, Large
.



Qty (
12
)



Heavy duty.



Stainless steel frame.



Four heavy duty castors.



Approximate size (100 liters) to be used for large size garbage
bags.

Page
24

of
67



item 31.

X
-
Ray, C
-
arm unit

Qty (
2
)



A sophisticated X
-
ray C
-
arm system suitable for use on patients in
beds, stretchers, or surgical tables is required for radiographic and
fluoroscopic imaging in general surgery,
orthopedic surgery
, critical
care units, and emergency care procedures. The sy
stem must meet,
or transcend the following specifications:


A.

General System Design:


1.

Mobile, consisting of two wheeled units; one supporting the C
-
arm and the control console and the other supporting display
monitors and image processing and recording
devices.

2.

Spill
-
proof, easy to clean and disinfect touch
-
type controls.

3.

Image Intensifier diameter (cm): ≥ 23.

4.

Variable field size (please specify).

5.

Camera type: CCD.

6.

Two high
-
resolution LCD monitors size ≥ 19”.

7.

Hard copy Device: Video printer.


B.

C
-
arm Feat
ures:

1.

Motorized

vertical movement range (cm): ≥ 40.

2.

C
-
arm depth (cm): ≥ 60.

3.

Pivotal rotation range (

): ≥

180.

4.

Orbital rotation range (

): ≥ + 90 to ≥
-
45.


C.

Generator:


1.

Nominal output power (kW) ≥ 7 kW.

2.

Generator type: High frequency.

3.

kV range:



Radiography:

40 to ≥ 110.



Fluoroscopy:

40 to ≥ 110.

4.

Pulse frequency (pps): variable frequency from up to ≥ 8.

Page
25

of
67


5.

Fluoroscopy kV and mA control: Automatic and manual.

6.

Fluoroscopy mA range (mA): 0.2 to 8.0 or wider.


D.

X
-
Ray Tube Assembly:


1.

Type of insert:
Rotating anode.

2.

Focal spot sizes: ~0.3 and ~0.6.

3.

Heat capacity for complete tube assembly (MHU): ≥ 1.5.


E.

Fluoroscopic Modes:


1.

Normal fluoroscopy with Last Image Hold (LIH).

2.

Pulse fluoroscopy for periodic refreshed image.

3.

Single
-
pulse snapshot mode for hard
-
copy image documentation.

4.

Subtraction mode.


F.

Image Storage And Processing:


1.

Bit depth ≥ 8.

2.

Display image Matrix: 1000 x 500 or better.

3.

Image storage capacity: ≥ 10,000.

4.

Image processing:



Noise reduction.



Edge enhancement.



Image reversal.



Image rotation.



Zoom and pan.



Electronic collimation.



Masking.



Subtraction.



Measurements.



Annotation.

5.

Software: Road mapping. (Please quote for all available software
packages).

6.

Fluoro replay: up to 25 fps.

7.

Removable storage: CD/DVD RW.


Page
26

of
67



item 32.

X
-
Ray Viewing Box



Qty. (1)


1.

Wall mounted.

2.

To fit at least 2 standard
x
-
ray

films simultaneously.

3.

Heavy duty construction free from sharp edges.

4.

On /off switch and intensity control.

5.

Standard size and rating fluorescent light tubes, readily accessible
for replacement.

6.

Mechanism to
hold films in place while viewing.


item 33.

EMERGENCY TROLLEY


Qty(13)



1.

Robust and heavy duty.

2.

Rust and corrosion proof metal and interior.

3.

All around bumpers.

4.

Swivel antistatic non
-
marking castors with braking system.

5.

Integrated rail f
or attachment of various paraphernalia.

6.

Five drawers at least, top drawer with internal partitions

7.

Drawers to be fitted on guide rails for easy sliding.

8.

Dispenser for syringes and cannulae.

9.

Chart board with ability to be attached to rail.

10.

Extension power c
ord with four or more power sockets with
indicator lamp along with hanging brackets.

11.

Disinfection solution dispenser with adaptor for rail
attachment.

12.

Holder for suction catheter.


item 34.

Instrument Cabinet





Qty. (
24
)


5.

Stainless steel construction.

6.

Doors to
have a stainless steel frame and glass sheets.

7.

Heavy duty handles with key lock.

8.

Inner stainless steel shelves with adjustable positions.


item 35.

Plaster Trolley
.





Qty (1)

1.

Heavy
-
duty construction material, i.e., Polymer,
Stainless Steel.

2.

Mobile on four antistatic, anti
-
scratch castors with brakes.

Page
27

of
67


3.

Three to five drawers with internal partitions to suit plaster tools
and casts.

4.

Waste basket with holder.

5.

Water container (approximately 5 liters), with holder to secure
it in p
lace.

6.

One or two upper shelves.

7.

Folded
-
up edges for the working surface.

8.

No sharp edges for the table.

9.

Working surface to give enough space for casting.



item 36.

Electrical Tourniquet, Double Cuff
.



Qty (
2

)

1.

Utilizes a system
that alternates pressure between two adjacent
cuff compartments without loss of tourniquet effect.

2.

Control unit to include:

a
-


Two gauges for the display of distal and proximal pressures
that react to the smallest pressure changes.

1.

Easy
-
to
-
read high
visibility graduation and needle
pointer.

2.

Pressure range up to 600 mmHg, with minimum accuracy
range (please specify).

b
-


Pressure release valves for distal and proximal pressures.

c
-


Built
-
in timer.

d
-


Simple control knob/ switch for pressure level.

e
-


Knob/ switch t
o switch from proximal to distal.

f
-


Connection to a local or central air supply.

3.

Dual
-
bladder cuffs that are durable, of high quality and
permanently labeled or colored to correspond with the labeling or
color of their respective control valves.

4.

Cuff fastene
r should keep the cuff tightly and evenly bound at
maximum operation pressure.

5.

Hose fittings should be securely attached.

6.

All control unit output ports, cuffs and cuff tubing should have
locking connectors.

7.

Cuffs should be provided with cleaning instructio
ns.

8.

Cuff, bladder and tubing should not be damaged by cleaning and
skin prepping agents commonly used in the OR.

9.

Four different cuff sizes to be included (including thigh).

10.

Mobile stand and basket for cuffs and accessories.

11.

A list of standard accessories
for the offered model (optional).


Page
28

of
67


item 37.

Pulse Oxmeter,

Qty. (
5
)


1.

Light weight, easy to use and handle unit.

2.

Microprocessor control with artifact rejection, anti
-
movement signal processing, and self
-
test capability.

3.

Compact and lightweight.

4.

L.C.D.
display.

5.

Microprocessor controlled with the ability to reject artifacts
resulting from ambient light interference, patient
movement, low body temperature etc.

6.

Self test mode.

7.

SPO2 range 0
-
99 %.

8.

Measurement accuracy not less that 97%.

9.

Accuracy ± 3%.

10.

Respons
e time < 8 seconds.

11.

Alarms to include: Audiovisual Hi/ Lo SpO2, pulse rate,
sensor off, low pulse, low battery.

12.

Alarm volume control.

13.

Pulse rate measurement range: 30


250 beats per minute
(bpm).

14.

Patient cable length ≥ 3 meters.

15.

Direct AC power supply and

rechargeable battery.

16.

8 hours or more memory for monitored data.

17.

Battery back
-
up for at least 4 hours continuous operation.

18.

Offers must include standard reusable neonatal sensors (a
set of two per unit).

19.

All available reusable and disposable probe types
shall be
quoted separately.

20.

A list of standard accessories for the offered model
(optional)
.


item 38.

APRON, LEAD

Qty. (
10
)



Apron, lead, wrap
-
around. Large 54 x 36 inch, 0.5 mm lead equiv.

Front, 0.25 mm lead equiv. Rear
protection with self gripping, hook and
-

loop type closure.


Page
29

of
67


item 39.

Blood warmer system






A: Blood warmer Qty. (
3
)


1.


It shall be a microprocessor
-
controlled dry blood warmer of all
infusions and transfusions in rout
ine and massive application.

2.


It shall have the following features:

3.

Temperature selection of 39°C, 41° or 43°

4.


Digital and illuminated temperature display in 0.1°C increments

5.

Two different infusions to be heated safely for parallel infusion

6.

Under tempe
rature alarm

7.


Automatic function test with each heater start

8.

Horizontal heat exchanger with approximately 11 windings for
universal application

9.

Three
-
way independent over heat safety switch off

10.

Audible/visual alarms and indicators for:

a.

High/Low temperatures

b.

End of transfusion

c.

Low flow

d.

Air in line

11.

Splash proof panel

a.


Heat protection sleeve

b.


Possibly to use standard infusion sets

c.

Universal fixation for fast and safe fixation on IV poles
and medical fixation rail

12.

It shall have the following technical data:

a.

Temperature selector: 39°C, 41°C and 43°C

b.


Warming
-
up time: < 1 minute

c.


Safety features: Multiple independent cut
-
off from
42°C (42, 42.5, 45°C)

d.

Type of operation mode: Continuous operation

e.


Operating tem
perature: 10
-
30°C

f.


Variable flow rate: > 100ml/min

13.

A list of standard accessories for the offered model (optional).


B:

1.

All the running requirements for
(A)
including consumables and
maintenance

kits sufficient for 360 sets for each system over a
period of one year at a rate of use per day.

Page
30

of
67


Requirements must be listed in a clear and itemized manner and prices
fixed for 5 years from the date of installatio


item 40.

Plaster Tools
.



A. Plaster Saw: Qty
(2
)



Electrical type.



Complete with va
cuum mechanism to minimize dust resulting
from cutting.



Heavy duty construction.



Round and reciprocating blades of all sizes to be offered and
priced separately.

B. Plaster sheers.

Qty (2
)

C
. Spreader.

Qty (2
)


item 41.

Multipurpose Trolley

Qty (
14
)



1.

Entirely made from stainless steel.

2.

Four strong legs

3.

Heavy duty swivel castors.

4.

Two shelves with upper edges.

5.

No sharp edges allowed.

6.

Push handle.

7.

Dimensions for each shelf
≈ 40 x 60 cm.

8.

Height ≈ 80 cm.


1.

Dimensions for each shelf
≈ 45x 180 cm.

2.

Height ≈ 80 cm.


item 42.

Stainless steel racks
.



Qty. (
6
)


1.

Made entirely in stainless steel.

2.

4
-
5 levels.

3.

Heavy duty.

4.

Approx. dimensions: 90x60x180 cm

Page
31

of
67



item 43.

STRETCHERS, PROCEDURAL

Qty (10)

This Procedural Stretcher shall meet or exceed the following general
features:

1.

Overall length: min


230 cm.

2.

Overall width: min


80 cm.

3.

Patient weight capacity: min

200 Kg.

4.

It shall have a radiolucent surface.

5.

It shall
have manual or hydraulic controls for:

6.

Height range adjustment: 55


85 cm approximately.

7.

Backrest: min


0
°
to 70
°
.

8.

Knee Gatch: min


0
°
to 25
°
.

9.

Trendelenberg and reverse Trendelenberg: min

±
15
°
.

10.

It shall include a patient mattress of:

11.

Length: min


200
cm.

12.

Width: min


65 cm.

13.

Thickness: min


12 cm for extra patient comfort.

14.

The mattress should be conductive and flame resistant.

15.

It shall include the following:

16.

Foldable side rails that allow zero
-
gap transfers.

17.

Arm/wrist rests with straps.

18.

Foot extender.

19.

IV receptacle.

20.

IV pole with dual IV hooks.

21.

Chart holder.

22.

Lateral X
-
Ray cassette (detector) holder.

23.

Oxygen bottle holder.

24.

Large (min

8”) swivel/steerable castors with locks.

A list of standard accessories for the offered


item 44.

Transport Ventilator for Adult/paediatric

Qty (
2
).


1.

A dedicated transport ventilator as mentioned in the original
catalogue/brochure

2.

AC volume breathes, AC pressure breathes, spontaneous CPAP,
Air/Oxygen blending, CPAP, SIMV
.

3.

Tidal volume: 50
-
100 ml

4.

Inspiration flow: adult 2
-
160 , paediatric 2
-
90

Page
32

of
67


5.

PEEP / CPAP 0
-
20 cm H
2
O.

6.

Built in expiratory valve.

7.

Audible apnea alarm.

8.

Battery backup for settings and operation.

9.

Operation through internal rechargeable battery able to
operate fo
r at least 3 hours.

10.

Ability to run on ambulance DC power supply


item 45.

Heat Lamp






Qty. (
3

)

1.

For adult and pediatric use.

2.

High quality castors with braking mechanism.

3.

Mounted on antistatic height adjustable pole.

4.

Pole to be made of heavy duty stainless steel or equivalent material.

5.

Timer for setting of heating duration.

6.

Single or dual light source.

7.

Two spare bulbs included.


item 46.

Surgical Headlight


Qty. (
3)


item 47.

Beds, manual, with mat
tresses

Qty. (
114)

1)

Heavy duty construction to suit continuous use.

2)

At least 4 sections. All to be manually driven.

3)

The dimensions of the sleeping surface should be >80X200 cm.

4)

Height adjustment from approximately 45 to 80 cm or better.

5)


Capability of the following movement Trendlenburg / Reverse
Trendlenburg, backrest, height, fowler positions and easy
release CPR

6)

Operational patient weight capacity > 225 kg.

7)

4 heavy
-
duty conductive castors approximately 15 cm in
diameter.

8)

Central brake

system with steering function.

9)

Either tuck
-
away or fold down side rails.

10)

Removable Head and Foot boards (all types and models to
be listed and priced separately).

11)


The bed should have at least 2 receptacles for IV poles
located on different sections of the bed which can host
detachable or foldable IV poles.

12)

Multiple drainage bag hooks Located on both sides
of the bed.

Page
33

of
67


13)

Protective revolving rubber bumpers at the bed
c
orners.

14)

Fire retardant, anti
-
microbial, solution resistant
foam mattress with non
-
latex cover.

15)

Set of compatible IV poles with double hooks.

16)

Matching patient chart holder with heavy duty
metallic paper clamp.

17)

Bed weight not to be less than 150 Kg

18)

All other

accessories especially built in traction system
to be listed and priced separately.


item 48.


Bedside Cabinet
.



Qty. (
114
)

1.

Standalone.

2.

Heavy
-
duty and robust.

3.

Complete with a minimum of one drawer.

4.

Lower cabinet.

5.

Mounted on four heavy
-
duty castors.

6.

Material, colour and design must be compatible with the beds and
all
available colours to be submitted with the offered.





item 49.

Over
-
bed table.


QTY(114)



1.

Standalone.

2.

Heavy
-
duty and robust.

3.

Mounted on four heavy
-
duty castors.

4.

Material, colour and design must be compatible with the beds and
all
available colours to be submitted with the offered.




item 50.

Resuscitation Bag (different sizes)

Qty (adult 18) (child5)

1.

One layer reliable bag.

2.

Over pressure relieving valve.

3.

100 % O
2

concentration (supply delivery) with O
2

accumulator.

4.


One way valve.

5.

Autoclavable.

Page
34

of
67


6.

All sizes should be included adult, infant and neonatal.

7.

All accessories to be mentioned and priced separate
ly.

8.

Samples must be submitted with the offered


item 51.

Oxygen Flowmeter wall type / single Qty (2 )

1.

Oxygen flow meter to provide accurate gas flow measured and
controlled within a range of 1
-
15

L/min, for use
in a variety of
respiratory therapy clinical devices.

2.

The flowmeter gauge should be float in tube

3.

Clearly labeled and color
-
coded flow meter

4.

The flowmeter shall include 300 ml reusable double lumen
humidifier.

mounted directly on the flowmeter
.

5.

oxygen fl
ow meter shall have the following specifications
:

a.

Maximum flow rate: 15 L/min


b.

Maximum pressure: approximately 100 PSI (690 kP)

c.

3

Accuracy
: +/
-

10% or better


6.

Heavy duty construction.

7.

Flow regulator.

8.

Wall mounted.

9.

Outlet thread 9/16".

10.

Quick connection
type: BOC.


item 52.

Oxygen Flowmeter with regulator / low flow

Qty. (45
)


1.

To be used with large size oxygen cylinders.

2.

Heavy duty metallic construction (stainless steel or brass).

3.

Two gauges indicating pressure before and after regulator.

4.

Flow range : 1
-
15 LPM.

5.

Bull nose connection.


item 53.

DDA cabinet





Qty. (
13
)

A high
-
quality heavy duty dangerous drugs cabinet to meet or surpass the
following specifications:

1.

The unit should be constructed from heavy
duty steel with


enameled finish & rounded corners.

2.

The unit should have double lock secure with warning light.

Page
35

of
67


3.

The unit should have at least two adjustable shelves.

4.


The unit should be securely mounted on wall.

5.

No sharp edges.

Please quote for all
available sizes and options

item 54.

SCALES, FLOOR, DIGITAL

Qty (
5
)

The floor digital scale shall have the following features:

1.

It shall have digital readout of patient weight.

2.

It should be switchable between Kg and lbs.

3.

It should weight accurately to the nearest 1
00g / 0.2 lbs or
better.

4.

It should be made from sturdy plastic material.

5.

Maximum capacity should be 200 Kg / 440 lbs or better.

6.

It should power up from AC voltage or batteries.



item 55.

Blood Gas Analyzer System consisting of :

Qty(2)

A: blood gas analyzer

1.

The most comprehensive and superior model of the offered
range.

2.

Must NOT use one
-
single pack reagent.

3.


Standard accessories list.

4.

Start
-
up kit.

5.

Non
-
cartridge type reagents.

6.

For measuring pH, PO
2
, PCO
2

and derivative parameters.

7.

Automatic Calculating HCO
3
, BE, O
2
Sat, TCO
2
.

8.

Maintenance free system

9.

Fully automatic calibrations

10.

Fully automatic clean routine

11.


Built in thermal printer

12.


To accepts syringe and capillary samples,

13.

Sample volume for capillary and syringe to be stated clearly and to
be in the range

of
μl
.

14.

Samples throughput not less than 30 samples per hour,

15.

Temperature controls, clear error messages.

16.

User friendly software

17.

It should support the connection to an internal LAN system or host
computer as part of Hospital Information System or Laborat
ory
Information System
.

Page
36

of
67


18.

A list of standard accessories for the offered model

(optional).


B:

All the running requirements for the system including reagents,
consumables, electrodes and maintenance kits sufficient for 360
consecutive days at a rate of 20
FULL blood gas tests per day.
Requirements must be listed in a clear and itemized manner



item 56.

UNITS FOR LAPAROSCOPIC SURGEY


Qty (
2
)


1.1

UNITS AND ACCESSORIES
:



1.

Min of Approx 23” Full HD LCD or LED Monitor

2.

3
-
chip
Camera system.


3.

Xenon 300 light

4.

Fiber
optic light cable

5.

Suction / irrigation for laparoscope.

6.

Electronic CO2 thermoflator 30 Lt / min.

7.

Veress pneumo
-
peritoneum needle

8.

High frequency generator

9.

Neutral electrode

10.

Connecting cable, for neutral electrode

11.

Unipolar high frequency cord

12.

Bipolar
high frequency cord

13.

Two
-
pedal footswitch

14.

Mobile video

cart

15.

Advanced image and data archiving system
.




1.2

Basic Set for Laparoscopic Surgery,

ALL NUMBERS ARE
APPROXIMATE. EQUIVALENT NOMENCLATURE IS ACCEPTABLE
:












Q
ty(

)

Telescopes and Instruments:

1.

STRAIGHT FORWARD TELESCOPE 0º, ENLARGED VIEW,
DIAMETER 10 MM, LENGTH 31 CM, AUTOCLAVABLE

Page
37

of
67


2.

FORWARD OBLIQUE TELESCOPE 30º, ENLARGED VIEW,
DIAMETER 10 MM, LENGTH 31 CM

3.

STRAIGHT FORWARD TELESCOPE 0º, ENLARGED VIEW,
DIAMETER 5 MM,
LENGTH 29 CM, AUTOCLAVABLE

4.

FORWARD OBLIQUE TELESCOPE 30º, ENLARGED VIEW,
DIAMETER 5 MM, LENGTH 29 CM

5.

TROCAR, SIZE 11 MM COMPLETE

6.

TROCAR, SIZE 6 MM, COMPLETE.

7.

REDUCTION SLEEVE, 11/5 MM

8.

THREAD SLEEVE, FOR TROCAR SIZE 6 MM

9.

THREAD SLEEVE, FOR TROCAR SIZE 11
MM

10.


QUINONES UTERINE GRASPING FORCEPS, BLUNT JAWS, WITH
ONE LARGE AND SMALL CONE AND CHANNEL FOR
PERTUBATION, LENGTH 24 CM

11.

QUINONES
-
NEUBUSER UTERINE GRASPING FORCEPS,
TOOTHED JAWS, WITH ONE LARGE AND SMALL CONE AND
CHANNEL FOR PERTUBATION, LENGTH 24CM

12.

CLICK
-
LINE MANHES GRASPING FORCEPS, ROTATING, WITH
MULTIPLE TEETH, WITH MANHES STYLE RATCHET, WITH
CONNECTOR PIN FOR UNIPOLAR COAGULATION

13.

CLICK
-
LINE MANHES DISSECTING AND GRASPING FORCEPS,
ROTATING, ATRAUMATIC, WITH MANHES STYLE RATCHET,
WITH CONNECTOR PIN

FOR UNIPOLAR COAGULATION

14.

CLICK
-
LINE KELLY DISSECTING AND GRASPING FORCEPS,
ROTATING, WITHOUT RATCHET, WITH CONNECTOR PIN FOR
UNIPOLAR COAGULATION

15.

TAKE
-
APART GRASPING FORCEPS, ATRAUMATIC,
DISMANTLING, U
-
SPRING HANDLE, WITH CONNECTOR PIN FOR
UNIPOLAR COAGUL
ATION

16.

CLICK
-
LINE CLAW FORCEPS, ROTATING, SINGLE ACTION JAWS,
WITH MANHES STYLE RATCHET, SIZE 10 MM, LENGTH 36 CM

17.

CLICK
-
LINE MANHES SCISSORS, ROTATING, SERRATED,
WITHOUT RATCHET, WITH CONNECTOR PIN FOR UNIPOLAR
COAGULATION

18.

CLICK
-
LINE HOOK SCISSORS, ROTATING
, WITHOUT RATCHET,
WITH CONNECTOR PIN FOR UNIPOLAR COAGULATION

19.

CLICK
-
LINE METZENBAUM SCISSORS, ROTATING, CURVED
JAWS, WITHOUT RATCHET, INSULATED, WITH CONNECTOR PIN
FOR UNIPOLAR COAGULATION

20.

CLICK
-
LINE BIOPSY PUNCH FORCEPS, ROTATING, WITH 2
TEETH, WITHOUT
RATCHET

Page
38

of
67


21.

CLICK
-
LINE SPOON FORCEPS, ROTATING, WITHOUT RATCHET

22.

TAKE
-
APART MANHES BIPOLAR COAGULATING FORCEPS,
WIDTH OF JAWS 1 MM, WITH CONNECTOR PIN FOR BIPOLAR
COAGULATION

23.

TAKE
-
APART MANHES BIPOLAR COAGULATING FORCEPS,
WIDTH OF JAWS 3 MM, WITH CONNECTOR PIN FOR BIPOLAR
COAGULATION

24.

MANHES HIGH FREQUENCY NEEDLE, INSULATED, FOR
SPLITTING AND COAGULATION

25.

COAGULATING AND DISSECTING ELECTRODE, L
-
SHAPED, WITH
CONNECTOR PIN FOR UNI
POLAR COAGULATION PUNCTURE
NEEDLE, LUER
-
LOCK, DIAMETER 1.6 MM

26.

SZABO
-
BERCI NEEDLE HOLDER “PARROT
-
JAW®”, STRAIGHT
HANDLE, WITH RATCHET

27.

SZABQ
-
BERCI ASSISTENT NEEDLE HOLDER “FLAMINGO
-
JAW®”,
STRAIGHT HANDLE, WITHOUT RATCHET

28.

SEMM NEEDLE HOLDER AND SUTURE GRASPE
R, WITH
AUTOMATIC BACK SPRING, SIZE 5 MM

29.

SEMM NEEDLE HOLDER AND SUTURE GRASPER, WITH
AUTOMATIC BACK SPRING, SIZE 3 MM

30.

ENDO LOOP LIGATURE, WITH ROEDER KNOT, WITH
ABSORBABLE SYNTHETIC THREAD, FOR SINGLE USE, STERILE,
PACKAGE OF 12

31.

CICE KNOT TIER, CLERMONT
-
F
ERRAND MODEL, FOR
EXTRACORPORAL KNOTTING, SIZE5 MM, LENGTH 36CM

32.

VERESS Pneumoperitoneum Needle, autoclavable, diameter
2.1 mm, length 13 cm

33.

VERESS Pneumoperitoneum Needle, autoclavable, diameter
2.1 mm, length 15 cm

34.

CLICK
-
LINE Grasping Forceps, size 5 mm,

length 30 cm

35.

CLICK
-
LINE SCHNEIDER Lymph Node Grasping Forceps, size 5
mm, length 36 cm

36.

CLICK
-
LINE KELLY Dissecting and Grasping Forceps, rotating,
size 5 mm, length 36 cm, with connector pin for unipolar
coagulation

37.

CLICK
-
LINE Scissors, rotating, size
5 mm, length 36 cm, with
connector pin for unipolar coagulation

38.

TAKE
-
APART MANHES Bipolar Coagulating Forceps, size 5 mm,
length 33 cm

39.

TAKE
-
APART MANHES Bipolar Coagulating Forceps, size 5 mm,
length 33 cm

Page
39

of
67


40.

RoBi Grasping Forceps, CLERMONT
-
FERRAND

model, rotating,
size 5 mm, length 36cm,

with connector pin for bipolar coagulation

41.

RoBi Grasping Forceps, CLERMONT
-
FERRAND model, rotating,
size 5 mm, length 36cm with connector pin for bipolar
coagulation

42.

RoBi KELLY Grasping Forceps, CLERMONT
-
FERRAND
model,
rotating, size 5 mm, length 36 cm, with connector pin for
unipolar coagulation

43.

Suction and Irrigation Tube, with lateral holes, size 5, length 36
cm

44.

Handle, straight, with trumpet valve

45.

Suction and Irrigation Tube, with lateral holes, size 5 mm,
len
gth 36 cm

46.

Suction and Irrigation Tube, size 5 mm, length 36 cm

47.

Coagulating and Dissecting Electrode, L
-
shaped, size 5 mm,
length 36 cm, with connector pin for unipolar coagulation

48.

Coagulating and Dissecting Electrode, spatula
-
shaped, blunt,
size 5 mm, leng
th 36 cm with connector pin for unipolar
coagulation

49.

Unipolar High Frequency Cord, length 300 cm

50.

Bipolar High Frequency Cord, length 300 cm

51.

Plastic Container for Sterilizing and Storage, for two telescopes,
perforated

52.

Silicone telescope holder, for two tel
escopes, size 10 mm.

53.

Uterine Manipulator, CLERMONT
-
FERRAND model

54.

COHEN Uterine Cannula, with LUER
-
Lock connection for
cleaning

55.

OLSEN Suction and Irrigation Tube, size 10mm

56.

Myoma Fixation Instrument, screw
-
shaped, size 5 mm

57.

Electronic morcellator complet
e system.

58.

C.C.L. Vaginal Extractor, diameter 11 mm, with insulated ball
-
shaped sphere, diameter 35 mm

59.

Click
-
line Claw Forceps, rotating, single action jaws, size 10
mm, length 36 cm

60.

Click
-
line vancallie adhesion forceps, one jaw fenestrated.

61.

Click
-
line
vancallie oviduct forceps, one jaw fenestrated.


item 57.

Ophthalmic Surgical Microscope with Chair. Qty. (
1
)


Page
40

of
67


A floor
-
standing surgical microscope for use in ophthalmic surgical
procedures is required.

1.

Magnification system that features motorized zoom for
anterior
and posterior segment surgery.

2.

Focus: Internal motorized and/or manual

3.

Fixed working distance with a range of 175 mm or 200 mm.

4.

Inclinable binocular tube for surgeon and assistant (please specify
range of inclination for both). PD adjustable.

5.

Magn
ification for eyepieces: 12.5x or better for main and 10x or
better for assistant.

6.

Medical grade monitor (either built
-
in or stand alone).

7.

Electromagnetic brake that guarantees easy and simple control.

8.

Foot
-
Pedal control: in addition, other controls to be

specified.

9.

Light source to be Xenon type with back up
.

10.

Digital video system with archiving capability on CD or DVD.

11.

Surgeon chair electrically operated.

12.

Any other additional features available in the system are to be
mentioned for comparison purposes.

13.


Al
l accessories and options must be listed and priced separately.

14.

A list of standard accessories for the offered model (optional)
.


item 58.

ENT Surgical Microscope




Qty. (
1
)

A floor mounted surgical microscope for use in ENT surgical procedures
is required.

1.

Magnification system that features motorized zoom with 1:6 ratio.

2.