REINFORCED CONCRETE RADIUS PIPE - ASTM C76

spyfleaUrban and Civil

Nov 25, 2013 (3 years and 9 months ago)

95 views

REINFORCED CONCRETE RADIUS PIPE - ASTMC76
Product Data Sheet
PIPE SIZE ID
(IN)
WALL THICKNESS
(IN)
PIPE SIZE OD
(IN)
DROP
(IN)
DEFLECTION
ANGLE (DEG)
RADIUS OF
CURVATURE
(FT)
18
2.5
23
3
7.43
29.71
18
2.75
23.5
3
7.28
30.35
21
3
27
3
6.34
34.88
24
3
30
3
5.71
38.75
27
3.25
33.5
3
5.12
43.27
30
3.5
37
3
4.64
47.79
33
3.75
40.5
3
4.24
52.31
36
4
44
3
3.90
56.83
42
4.5
51
3
3.37
65.88
48
5
58
3
2.96
74.92
54
5.5
65
3
2.64
83.96
60
6
72
3
2.39
93.00
66
6.5
79
3
2.17
102.04
72
7
86
3
2.00
111.08
OD
ID
DROP
DEFLECTION
ANGLE
4’
3.875’
REINFORCED CONCRETE
ROUND
PIPE
STANDARD WYE DIMENSIONS
MAINLINE
BRANCH
L1
(IN)
Δ = 30
º
Δ = 45
º
Δ = 60
º
Δ = 90
º
TEE
ID (IN)
LGT (FT)
ID(IN)
OD
(IN)
L
L2
L
L2
L
L2
L
L2
72 THRU12 8
12
16 12
26
40
20
28
17
21
12
12
72 THRU15 8
15
19.5 12
29
46
22
31
18
23
12
12
72 THRU18 8
18
23 12
32
52
23
35
19
25
12
12
72 THRU21 8
21
26.5 12
35
58
25
38
20
27
12
12
72 THRU24 8
24
30 12
38
64
27
42
21
29
12
12
72 THRU27 8
27
33.5 12
41
70
29
45
22
31
12
12
72 THRU30 8
30
37 12
44
76
30
49
23
33
12
12
72 THRU33 8
33
40.5 12
47
82
32
52
24
35
12
12
72 THRU36 8
36
44 12
50
88
34
56
25
37
12
12
72 THRU42 8
42
51 12
56
100
37
63
27
41
12
12
72 THRU48 8
48
58 12
62
112
41
70
29
45
12
12
72 THRU54 8
54
65 12
68
125
44
77
31
50
12
12
72 THRU60 8
60
72 12
74
137
48
84
33
54
12
12
72 THRU66 8
66
79 12
80
149
51
91
35
58
12
12
72 8
72
86 12
86
161
55
98
37
62
12
12
12” MIN
TYP
Δ
PLAN VIEW
ID
L
L
2
MAIN LINE LGT
L
1
ID
OD
REINFORCED CONCRETE
ROUND
PIPE
STANDARD BEND DIMENSIONS
PLAN VIEW
Δ
OD
ID
L
1
L
L
2
PIPE
SIZE
ID (IN)
PIPE
SIZE
OD(IN)
BEND
LGT
(FT)
L (IN)
Δ = 15
º
Δ
= 30
º
Δ
= 45
º
Δ
= 60
º
Δ
= 90
º
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
12
16
8
48
47
49
46
50
45
51
43
53
40
56
15
19.5
8
48
47
49
45
51
44
52
42
54
38
58
18
23
8
48
46
50
45
51
43
53
41
55
36
60
21
26.5
8
48
46
50
44
52
43
53
40
56
35
61
24
30
8
48
46
50
44
52
42
54
39
57
33
63
27
33.5
8
48
46
50
44
52
41
55
38
58
31
65
30
37
8
48
46
50
43
53
40
56
37
59
29
67
33
40.5
8
48
45
51
43
53
40
56
36
60
28
68
36
44
8
48
45
51
42
54
39
57
35
61
26
70
42
51
8
48
45
51
41
55
37
59
33
63
22
74
48
58
8
48
44
52
40
56
36
60
31
65
19
77
54
65
8
48
44
52
39
57
35
61
29
67
15
81
60
72
8
48
43
53
38
58
33
63
27
69
12
84
66
79
8
48
43
53
37
59
32
64
25
71
8
88
72
86
8
48
42
54
36
60
30
66
23
73
5
91
PIPE SIZE
(IN)
WALL
THICKNESS A (IN)
OD (IN)
SLOPE
DESIGN/
JOINT
LGT (FT)
C (IN)
L (IN)
SLOPE
DESIGN/
JOINT
LGT (FT)
C (IN)
L (IN)
SLOPE
DESIGN/
JOINT
LGT (TF)
C (IN)
L (IN)
15 2¼ 19½
3:1 1/6 13½ 58½
4:1 2/6 42 78
6:1 2/6 27 117
18 2½ 23
3:1 1/8 21 75
4:1 1/8 12 84
6:1 2/8 42 150
21 2¾ 26½
3:1 1/8 16½ 79½
4:1 2/8 54 138
6:1 2/8 33 159
24 3 30
3:1 1/8 12 84
4:1 2/8 48 144
6:1 2/8 24 168
27 3¼ 33½
3:1 2/8 55½ 136½
4:1 2/8 42 150
6:1 2/8 55½ 136½
30 3½ 37
3:1 2/8 51 141
4:1 2/8 36 156
6:1 3/8 15 177
33 3¾ 40½
3:1 2/8 46½ 145½
4:1 2/8 30 162
6:1 3/8 45 243
36 4 44
3:1 2/8 42 150
4:1 2/8 24 168
6:1 3/8 36 252
42 4½ 51
3:1 2/8 33 159
4:1 2/8 12 180
6:1 3/8 18 270
48 5 58
3:1 2/8 24 168
4:1 3/8 48 240
6:1 4/8 48 336
54 5½ 65
3:1 2/8 15 177
4:1 3/8 36 252
6:1 4/8 30 354
60 6 72
3:1 3/8 54 234
4:1 3/8 24 264
6:1 4/8 12 372
ROUND PIPE SAFETY END TREATMENT
Product Data Sheet
1.FOR SLOPES AND SIZES NOT
LISTED CONTACT J & G CONCRETE
PRODUCTS AT 972-937-9200.
2.SLOPE CUTS WILL BE ROUGH CUT
APPROXIMATELY 2” WIDE AND MUST
BE FINISHED BY CONTRACTOR.
3.THESE PRODUCTS MEET THE
REQUIREMENTS FOR TEXAS
DEPARTMENT OF
TRANSPORTATION TYPE II
SAFETY END TREATMENTS.
DOWNSTREAMSECTION
UPSTREAM SECTION
A
L
C
DESIGN 2
2
UPSTREAMSECTION
DOWNSTREAMSECTION
L
A
C
DESIGN 4
DS
SECTION
US
SECTION
A
L
C
DESIGN 1
UPSTREAM SECTION
DOWNSTREAMSECTION
A
C
L
DESIGN 3
3
18” 6:1 SET PR C=42” 2-8’ L=12’-6”
L
8’
8’
C
UPSTREAM
SEC
TION
DOWNSTREAM
SECTION