Attachment C

















WEATHERIZATION CONTRACTOR (NAME OF FIRM)



All quotations in response to this request for quotations (RFQ) must comply with the following instructions failure to do so
may result in disqualification.


All work shall comply with

the DHS BCAEO Technical Division’s Technical Weatherization Policy Manual, Weatherization
Fi
el
d Manual (copies are available for download at Michigan.gov), State and local codes.

All Materials used in provision of services must meet or exceed 10 CFR 440 A
ppendix A: “Standards for Weatherization
Services”.


Bidders

are required to list installation total cost per unit item (all prices to include material and labor separate costs).





















Contra
ctor Signature








Date




Weatherization

Measures and Description



Total



Major Bypasses







Drywall Repair
-

Walls (including prep) drywall, tape & mud 1 coat

sq. ft.





Drywall Repair
-

Ceiling (including prep) drywall, tape & mud 1 coat

sq. ft.





Patch holes in Wall/Ceiling (each ar
ea)

each





All door and window replacement cost shall include disposal of old material applicable permits, etc. and work







preformed in accordance with Lead Safe Work regulations







Steel pre
-
hung entry door (6 panel door w/lockset, deadbolt,
peep view, caulking, interior and exterior trim)

each





Steel pre
-
hung entry door w
/lite

(6 panel door w/lockset, deadbolt, caulking, interior and exterior trim)

each





Steel replacement insert door (lockset, deadbolt, peep view, caulking, interior
trim)

each




Steel replacement insert door

w/lite

(lockset, deadbolt, caulking, interior trim)

each




Insulated dual pane, Low
-
E, white vinyl slider window including caulking, interior and ext. trim. (LSW if app)

sq. ft.





Insulated dual pane, Low
-
E, white vinyl Picture window including caulking, interior and ext. trim. (LSW if app)

sq. ft.





Basement prime
-

Insulated dual pane, Low
-
E, white vinyl window including caulking, trim, (LSW if applicable)

sq. ft.





Basement prime window replace
ment with Glass block (includes vent) mortared in place

sq. ft.





Reframe basement window opening (jamb) w/treated lumber & mortared in place

each





Broken glass replacement (price is sq. inch and includes glazing)

sq. inch





Basement window glas
s replacement or glass pane (under 200 sq. inches)

each





Flue collar (at ceiling)

each





Install storm over bad prime window (interior application) includes caulking

each





Install storm over bad prime window (interior application) includes caulk
ing
-

over 100 united inches

each





Board over basement window (w/treated lumber)

sq. ft.





Rebuild basement bulkhead door (w/treated lumber)

each





Frame basement door opening & install reinforced 3/4" plywood door (w/hinges, latches, wx strip,

sweep.)

sq. ft.





Blower Door Pressure Test
-

test includes calculating the Air Changes per Hour (ACH) in the field. Sealing the home to a level allowed



by the ACH calculation and performing final blower door test to confirm the appropriate buildi
ng tightness level of dwelling



Blower Door Pressure Testing

each

















W
eatherization

Measures and Description






Infiltration
-

Doors



Total



Weather
-
strip door (aluminum weather
-
strip w/ Silicone Flap)

each





Bumper threshold
-

a
luminum (in wood or concrete)

each





Under door threshold
-

aluminum (in wood or concrete)

each





Door shoe

each





Door sweep
-

aluminum w/ triple flap

each





Replace existing lockset

each





Replace existing deadbolt

each





Drill hole and

install new deadbolt

each





Install conversion kit (for exterior lock)

each





Install reinforcement kit (for exterior lock)

each





Check, fit, free door (includes adjustment of strike plate, hinges, door to open/close freely)

each





Door jamb
-

replace strike side only

each





Door jamb
-

repair strike side

each





Jamb extension (exterior)

each





Door sill

each





Replace mail slot

each





Remove & reinstall storm door

each





Replace storm door closure

each





Replace storm d
oor handle and latch

each





Replace storm door wind chain

each





Replace storm door latch (for existing handle)

each





Interior casing: 2 1/4" casing (must be primed
-
includes caulking)

ln ft





Exterior trim : dimensional lumber up to 1X6" (must

be primed
-
includes caulking)

ln ft.





Brick mold (must be primed
-
includes caulking)

ln ft.




















































Infiltration
-

Windows



Total



Glaze single pane window

ln ft.





Install sash lock (cam
-
style)

ea
ch





Weather
-
strip window (V
-
style)

each





Check, fit, free window (includes freeing the sashes and trimming so rails meet in the center)

each





Pulley covers (per pair)

pair





Corner irons (each)

each





Window sill

each





3/4' Plywood ar
ound A/C in window and caulk (seal between sashes)

each





Foam insert between sashes (for existing window A/C)

each





Air conditioning cover

each





Gearbox for casement window & lubricate hinges

each





Interior trim 2 1/4" casing

ln f t.





Ex
terior trim: dimensional lumber up to 1"x6" (must be primed
-
includes caulking)

ln f t.





Wood replacement: Window stop (must be primed
-
includes caulking)

ln f t.





Wood replacement: 1"x3" framing (must be primed
-
includes caulking)

ln f t.













Weatherization

Measures and Description






Infiltration
-

Miscellaneous



Total



Caulking
-

remove old and apply new (per lineal foot)

ln ft.





Switch plate or outlet cover (includes gasket)

each





Seal Milk chute
-

Insulate with R
-
13 fiberglas
s, secure with screws and caulk

each





Seal coal chute
-

Insulate with R
-
13 fiberglass, secure with screws and caulk

each





Seal whole house fan w/ insulated vinyl cover at ceiling (use hook and loop fastener)

each





Misc. Infiltration Repairs : (
L
abor Cost per hour)
-

per hour





Infiltration/ Bypass Sealing







Bypass Sealing
-



Total



Bottom of Rafter Runs, per linear foot w/ vinyl
-
faced insulation or air seal bags.

ln ft.





Seal Floor Cavity Under Knee wall, per linear foot, w/vinyl
-
f
aced insulation or air seal bags

ln ft.





Seal Wall Cavity at top or bottom/ Balloon framing w/ vinyl
-
faced insulation or air seal bags

ln ft.





Bottom of Rafter Runs, With /2 part closed
-
cell foam

ln ft.





Seal Floor Cavity Under Knee wall, w
ith 2 part closed
-
cell foam

ln ft.





Seal Wall Cavity at Top or Bottom/ Balloon framing, with 2 part closed
-
cell foam.

ln ft.













Infiltration
-

Attic Access (within thermal boundary)







I
nstall ceiling access
-

existing opening







(1x

4 trim, CDX plywood, w/s, Insulate to attic R value)

each





Weather
-
strip and insulate ceiling access panel to attic R value
-

secure and caulk trim

each





Install Knee wall access
-

existing opening.







(1x 4 trim, CDX plywood, 2 hinges, 2 bar
rel bolt, insulate pillow)

each





Repair, weather
-
strip and insulate existing knee wall access.

each





Pull down stair treatment ( box over)







(plywood, insulate, weather
-
strip, caulk)

each













Infiltration
-

Crawl Space Access (withi
n thermal boundary)







Install crawl space access panel and framing
-

existing opening







(3/4 treated plywood, 2 x 8 frame, stops, 4 zinc barrel bolts, wxstrip, R
-
13 Insulate)

each





Replace foundation/ floor access panel
-

3/4" plywood, R
-
13 In
sulation pillow, wx
-
strip.

each





Air seal, weather
-
strip and R
-
13 insulation to existing access.

each





Exterior Wall Insulation











Holes

(mortar holes if blown thru brick). Includes permits, fees, etc. as applicable







Blown cellulos
e Dense Pack 2x4 wall cavity

sq. ft.





Blown Cellulose Dense Pack 2x6 wall cavity

sq. ft.





Fiberglass batts: R
-
13

sq. ft





Set up charge
-

Check for insulation (when already existing)

each





Wall Insulation
-

Additional Costs



Total



Insta
ll S
-
type fuses w/ adapters

each





Other:







Storm Windows







Vertical or horizontal slider (w/Screen)
-

includes caulking
-

up to 100 united inches

each





Picture window O.S.R. (out side removal)
-

up to 100 united inches

each





Storms o
ver 100 united inches (additional)















Attic Insulation



Total



Includes permits, fees, etc. as applicable







Open attic: blown cellulose R
-
11

sq. ft.





Open attic: blown cellulose R
-
19

sq. ft





Open attic: blown cellulose R
-
30

s
q. ft.





Open attic: blown cellulose R
-
38

sq. ft.




Open attic: blown cellulose R
-
49

sq. ft.




Open attic: Install fiberglass batts R
-
13

sq. ft





Open attic: Install fiberglass batts R
-
19

sq. ft.





Knee walls: Install fiberglass batts R
-
13

sq.

ft.





Rafter Runs: Tube slopes to dense pack

sq. ft.





Additional Attic Insulation / Ventilation



Total



Attic Prep: Major
-

Extensive knob & tube, extensive # recessed lights, ceiling drops

per hour





Drill / Lift boards to insulate and/ or a
ir barrier knee wall (price is labor/hour).

per hour





Slash existing vapor barrier. (Price per sq ft).

sq. ft





Remove existing insulation and disposal. (price per sq ft)

sq. ft





Install 60 sq. in. NFA slant back roof vent
-

cut opening in roof (
color to match existing)

each





Replace existing roof vent
-

Install 60 sq. in. NFA

each





Install standard size gable vent and cut opening in wood

each





Install standard size gable vent and cut opening in aluminum or vinyl (install J channel)

ea
ch





Replace existing standard size gable vent:

each





Rescreen existing gable vent (w/hardware cloth
-
no window screen)

each





Install soffit vent
-

8" x 16" or 4" x 16" (Includes chute)

each





Install soffit vent chute 16" or 24"

each





Cu
t opening between attics (large enough to access adjacent attic)

each





Other:







Foundation Insulation



Total



Add R
-
13 unfaced Fiberglass to basement / crawl space box sills.

sq. ft.





Add R
-
19 unfaced Fiberglass to basement / crawl space
box sills.

sq. ft





Add R
-
11

Fiberglass to floor joist cavities (includes screen/mesh or wire supports @ 2' apart)

sq. ft.





Add R
-
13

Fiberglass to floor joist cavities (includes screen/mesh or wire supports @ 2' apart)

sq. ft.




Add R
-
19
Fiberglas
s to floor joist cavities (includes screen/mesh or wire supports @ 2' apart)

sq. ft.



Add R
-
30
Fiberglass to floor joist cavities (includes screen/mesh or wire supports @ 2' apart)

sq. ft.




Add R
-
13 Fiberglass batts to perimeter foundation walls & 2'
drape.

sq. ft.





Add R
-
19 2
-
part closed cell foam to basement/ crawl space box sills.

sq. ft.





Add R
-
10 2 part closed
-
cell foam to perimeter foundation walls & 2' drape

sq. ft.





Install 6 mill plastic on ground
-

overlap seams 12" & up wall 6"
(sq. ft.)

sq. ft.





Additional Foundation Insulation / Ventilation



Total



Install Crawl space access
-

new







(3/4 exterior plywood, 2 x 8 exterior framing, 2 zinc barrel bolts, w/s, insulate)

each





Replace existing Foundation Vent (use ca
st aluminum or abs plastic type)

each





Install new Foundation Vent
-

remove block (use cast aluminum or abs plastic type)

each





Other:























Health and Safety



Total



Smoke Detector
-

battery operated

each





Dryer Vent
-

hood only
-

existing opening

each





Dryer flex duct only, 2 elbows, clamps, up to 8' (UL approved flex)

each





Dryer vent w/ flex duct, 2 elbows, clamps
-

replace existing up to 8' (incl. caulking)

each





Dryer vent w/ rigid duct, 2 elbows, clamps
-

replace existing up to 8' (incl. caulking)

each





Dryer vent w/ rigid duct
-

complete (cut new opening)

each





Exhaust bath fan through roof or gable
-

(exhaust hood with damper, insulated duct)

each





Duct and vent kitchen exhaust fan
-

(exhaus
t hood w/ damper, rigid duct, and insulate duct

each





Replace existing kitchen exhaust hood vent

each





Replace existing bath exhaust fan


per ASHRAE 62.2 requirements

each





Replace existing exhaust fan
-

motor only per ASHRAE 62.2 requiremen
ts

each




Install variable speed fan control/timer

each



Install exhaust fan complete (electrical circuit, fan, ducting, exhaust hood)

each



Install continuous run exhaust fan controller

each




Drop leg on water heater (pressure relief valve)

ea
ch




LSW
-

window replacement

each



LSW
-

door replacement

each



Furnace Filter

each



Furnace Filter cover

each








Compact Fluorescent Light Bulbs



Total



CFL Bulb
-
15
-
18 watt (energy star rated)

each





CFL Bulb
-
23
-
25 watt (energy star r
ated)

each





CFL Bulb
-

23
-
25
-

watt flood (energy star rated)

each





Duct/ Pipe Insulation







Install duct insulation (R
-
3 minimum)
-
Reclectix or equivalent (sq. ft).

sq. ft.





Install pipe insulation (R
-

3.5 Minimum) (lin. Ft.)

ln ft.





Duct Sealing /Repair







Secure and seal ducts w/ butyl
-
back foil tape or mastic

each





Other:




























Manufactured Home Measures



Total



Replace Combination Door (includes lockset, deadbolt, caulking, trim)

each





Replace

Secondary Door (includes lockset, deadbolt, caulking, trim)

each





Replace Water Heater Door

each





Replace Prime Window


aluminum, single pane complete

UI




Replace Prime Window


vinyl, insulated glass complete

UI




Replace Self Storing St
orm

each





Replace Interior Storm

each





Seal Ductwork with Mastic

ln. ft.





Seal or Repair floor register boot connections w/mastic or labeled butyl tape

each




Seal end of trunk line duct

each




Floor Repair/Replacement

sq. ft





Repair/R
eplace rodent barrier

sq. ft





Manufactured Home Insulation



Total



Blown Fiberglass Ceiling Insulation

sq. ft.




Blown Fiberglass Wall Insulation

sq. ft.



Fiberglass Batt Wall Insulation

sq. ft.



Belly Insulation


Blown Fiberglass

sq. ft.




Belly Insulation


Fiberglass Batt with Rodent Barrier

sq. ft.






























Mechanical Measures



Total



Domestic Hot Water Heaters





Replacement shall include removal and disposal of the old tank. Installation
of
new tank
will be
in

accordance with manufacturers’ specifications and applicable codes.
Price to
include permits.





30 gallon natural gas

each





40 gallon natural gas

each





50 gallon natural gas

each




30 gallon natural gas
-

Power Vented

each



40 gallon natur
al gas

-

Power Vented

each



50 gallon natural
gas
-

Power Vented

each



30 gallon natural gas


Sealed Combustion

each



40 gallon natural gas


Sealed Combustion

each



50 gallon natural gas


Sealed Combustion

each







30 gallon electric

each




40 gallon electric

each





50 gallon electric

each











30 gallon natural gas


Manufactured Home

each




40 gallon natural gas


Manufactured Home

each
















Replacement Furnace



Total



Replacement shall include removal and dis
posal of the old furnace. Installation new
furnace will be in accordance with manufacturers’ specifications and applicable codes.
Price to include permits, filter rack with removable air tight cover.





80% efficient, natural gas, 35,000 to 100,000 BTU
rated input

each



92% efficient, natural gas, 35,000 to 100,000 BTU rated input

each



Boiler, Hot Water, Complete

each



Boiler, Steam, Complete

each



Mobile Home Furnace, natural gas 20,000 to 80,000 BTU rated input

each







Other:




Furnace
Clean and Tune

each



Thermostat

each



Chimney Liner

each



Filter

each



Filter cover

each



Replace existing bath exhaust fan


per ASHRAE 62.2 requirements

each



Replace existing exhaust fan
-

motor only per ASHRAE 62.2 requirements

each



In
stall variable speed fan control/timer

each



Install exhaust fan complete (electrical circuit, fan, ducting, exhaust hood)

each



Install continuous run exhaust fan controller

each