CONTENT

REVISION HISTORY

................................
................................
................................
................................
................

3

PURPOSE OF THE DOCUMENT

................................
................................
................................
..............................

4

APPOINMENT

................................
................................
................................
................................
........................

5

TECHNICAL SPECIFICATIONS

................................
................................
................................
................................
.

6

GENERAL VIEW

................................
................................
................................
................................
......................

7

PCB BOARD

................................
................................
................................
................................
............................

9

OPERATIO
N MODES

................................
................................
................................
................................
............

10

EXTERNAL DEVICE INTERFACE SELECTION

................................
................................
................................
..........

11

START OF OPERATION

................................
................................
................................
................................
.........

12

LIST OF WCD COMMANDS IN CONFIGURATION MODE

................................
................................
.....................

13

RESET

................................
................................
................................
................................
...........................

13

STACK

................................
................................
................................
................................
...........................

13

REG

................................
................................
................................
................................
..............................

13

LIST ADDR

................................
................................
................................
................................
....................

14

ADD ADDR
................................
................................
................................
................................
....................

14

DEL ADDR

................................
................................
................................
................................
.....................

14

GET COM
................................
................................
................................
................................
......................

15

SET COM

................................
................................
................................
................................
......................

16

GET PACKVALUE

................................
................................
................................
................................
..........

17

SET PACKVALUE

................................
................................
................................
................................
...........

17

GET PACKTIMEOUT

................................
................................
................................
................................
......

18

SET PACKTIMEOUT

................................
................................
................................
................................
......

18

GET XBEE

................................
................................
................................
................................
......................

19

SET XBEE

................................
................................
................................
................................
......................

19

X
-
CTU UTILITY

................................
................................
................................
................................
......................

20

CABLI
NG

................................
................................
................................
................................
..............................

21

SUPPLY PACKAGE

................................
................................
................................
................................
................

22

EXAMPLE OF APPLICATION ON PETROL STATION

................................
................................
...............................

23




WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
3

from
23


REVISION HISTORY



REV

DATE

BY

SECTION

DESCRIPTION

1.
0
1

0
3
.01.20
1
3

EV

All

First

release


WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
4

from
23


PURPOSE OF THE DOCUMENT


This
Technical Guide
is intended for studying of
wireless communication device
. It contains basic
information regarding
its board interfaces and connectors, configurat
ion and adjustment
s
, connection to
fuel dispensers and external devices
, cablings
. Information regarding
connection to specific
models of
fuel
dispensers and correspondent configuration of the
wireless communication device

can be
received upon
request to T
ECHNOTRADE LTD company
.


Due to a reason that
wireless communication device

is constantly being developed in direction of
improvements of its possibilities, changes are possible in final version, which are not described in given
Technical Guide
.


During th
e system development process given
Technical Guide
will be also expanded and updated and new
chapters will be added. Latest version of this
Technical Guide
can be downloaded from the
wireless
communication device

web
-
page:
http://www.technotrade.ua/wireles
s_communication_device.html
.


TECHNOTRADE LTD hereby permits reproduction of this document as may be required by any of the
customers or OEMs wishing to use it.


This document has been carefully prepared and is believed to be accurate. However TECHNOTRADE
LTD, its
employees and its agents do not assume responsibility for its use either directly or indirectly.
TECHNOTRADE LTD shall not be liable for technical or editorial errors or omissions which may appear in this
document.

TECHNOTRADE LTD reserves a right

to make changes to this document at any time without
notice. Prospective users of this document should contact TECHNOTRADE LTD at the time they wish to
use
wireless communication device

together with

their products to become aware of any updates that may
apply.


All technical questions regarding the
wireless communication device
are welcome to be asked on support
mailbox
:
support_1a@technotrade.ua
. Our support team will be glad to help you.

In case if you f
ind any mistake
s
, omissions in this document or have any suggestions o
n

improvements to
this document, please feel free to e
-
mail them our support mailbox:

support_1a@technotrade.ua
. We will
be grateful to
you for this valuable information.






WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
5

from
23


APPOINMENT


Wireless communication device (later in text named as WCD)

is functionally and structurally complete
device for wireless communication

between

devices with

one of
interfaces
:

-

RS
-
232

-

RS
-
485


WCD is

used as
a wire
less alternative to wired lines and is

installed

to replace the cable
s (between

external
device
s) with

radio communication
.
WCD

is designed to transmit / receive data
via radio channel at a speed
of

up to 9600

bit / s in the frequency range (2410
-
246
5) MHz
with

the t
ransmitter output power up to 1
0

mW
.

If

cable routing between devices

(which usually are using
wired communication chan
nels

for data
exchange
)

is impossible,

then

it is necessary to look for other means of communication
,

other than wire
d
.
Wireless transmission of data between devices is one of possible solutions
for this

problem.
WCD

is a
variation of radio extenders for
communication
line
s

us
ing

for communication interface
s

RS
-
232
and

RS
-
485.


WCD

is connected to an external device

via

co
mmunication
interface RS
-
232 or RS
-
485 (2
-
wire or 4
-
wire)
and is

"transparent"

for the devices (
additional

modification of

the device is

not

required
)
.

After switching
-
on WCD itself scans the radio channel, searching for any other WCD

devices

in the networ
k
and establishes contact with them without any commands from the device, connected to WCD. Thus,
devices connected to the WCD can exchange data

over the air the same way as they did it using wired
communication.

WCD operates in a mode of direct access to
the radio channel, thus, external devices can exchange data
over the radio channel, using their own protocols, addressing, coding etc. Using the protocol of addressing
between external devices, WCD can be used to connect a group of external devices
in
to th
e
common
network.

WCD is designed for application

in different remote control systems,

data collection

system
, etc.
WCD

can
be

easily integrated into already
existing

system
s

without
redevelopment

of the software.





WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
6

from
23


TECHNICAL SPECIFICATIONS



Power supply
v
oltage

+
9



+
24

V DC

Maximum power consumption

from the power supply
in
transmission mode

0,36

W

Maximum power consumption

from the power supply

in idle mode

0,06

W

Transmitter output power, not more

than

10
0 mW

Data transfer
baud
rate
via radio chann
el

Up to 9600

baud

Data transfer rate
via

interfaces (RS
-
232, RS
-
485)
with external device
s

1200 ... 115200

baud

O
perating distance between
WCD (in
doors
)
, no
t

more

than

100

m

O
perating distance between
WCD (out
doors

on open space
)
, no
t

more

than

1500

m

Operating frequency range

2410 ... 2465

MHz

Connector for external
antenna

RP
-
SMA

(RSMA)

Interfaces

for

communication with external devices

RS
-
232

RS
-
485
2
-
wire

RS
-
485
4
-
wire

C
limatic conditions

T
emperature

-
10° …
+
45°

С

H
umidity

5...95 %

O
verall dimensions

90 х 180 х 67
mm

W
eight

260
g


WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
7

from
23


GENERAL VIEW


WCD

is supplied in a black plastic box with LEDs and connectors located on front and back sides of it.



On the front panel of the WCD connector
of
RP
-
SMA (RSMA) for

an external antenna

is located

and

also

5
groups of LEDs for

indication of

WCD

operation.



LED "
POWER
"
-

WCD

indication of operating modes:

LED "
POWER
" behavior

Device operation modes

C
onstant
shining

WCD is in data mode

1
short
shining

WCD

is in con
figuration mode

2
short
shinings

WCD is in
X
-
CTU

mode


LED "
RX
"

informs that
WCD

receives data.

LED

"
TX
"

informs that
WCD

sends data.


WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
8

from
23


As transceiver

in
WCD

is used Zigbee
-
module
,

that has its own set of
states
. These
states
are described in
the documenta
tion
on

Zigbee
-
module
s

and

are

indicated

by

LED "
MODE
".

Complete documentation on the
used Zigbee
-
modules can be downloaded from official website:
http://ftp1.digi.com/support/documentation/90000982_H.pdf
.

Shining of a LEDs group
"
LEVEL
" indicates
level

of

received signal
.

On back side of the WCD connectors of power supply and interface
for connection external devices
are
located.


Power
supply to WC
D can be made using either

using

-

power supply

plug

with
5.5

mm (0.22

in) in outside diameter and 2.1

mm (0.
083

in)
In inside diameter

into the connector DJK
-
02 installed on WCD PCB board

-

direct cables screwed to power supply
terminal block

installed on WCD PCB board


Range of power supply voltage is from +
9

V DC

to +
24

V DC.


Connection of external devices is m
ade through a
DB
-
9
F

connector, which can be configured either to RS
-
232 or RS
-
485 interface. This connector can be used for connection of external device and also for
connection of a personal computer for configuration or reprogramming of the WCD.


DB
-
9F c
onnector




Contacts of
D
B
-
9
F

connector

1

2

3

4

5

6

7

8

9

RS
-
232

-

T
xD

R
xD

-

Gnd

-

-

-

-

RS
-
485 2
-
wire

A

-

-

B

-

-

-

-

-

RS
-
485 4
-
wire

RxA

-

-

RxB

-

TxA

-

-

TxB




WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
9

from
23


PCB
BOARD


Selection of WCD operation mode is made using jumpers located on WCD PCB bo
ard.



WCD PCB board
contains jumpers for selection of:

-

operation mode (see section “Operation modes”)

-

interface for connection to external device (RS
-
232 or RS
-
485) (see section “External device interface
selection”)




WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
10

from
23


OPERATION MODES


Selection of WCD o
peration mode is made using jumpers located on WCD PCB board.

DATA mode

This mode is the main mode of
WCD
. In this mode data from the

external

device

connected to WCD is sent

through

radio channel

t
o

address
es
, specified in
address table of the
WCD

(see co
mmand "LIST ADDR"

in
section “
List of WCD commands

in configuration mode

)
.

To select this mode, you need to set the jumpers:

Jumper
XS
5
:

place
jumper

Jumper
P
5
:

short circuit (close) positions
2
-
3

In data mode
-

«POWER» LED will be constantly
shining
.

X
-
CTU mode

This mode allows using the X
-
CTU utility to configure the Zigbee
-
module within WCD.


To select this mode, you need to set the jumpers
:

Jumper
XS
5
:

place
jumper

Jumper
P
5
:

short circuit (close) positions
1
-
2

In

X
-
CTU

mode
-

«POWER»

LED will blink

with
two short
shinings
per second (double
shining
every second).

Read more about X
-
CTU utility for configuration of Zigbee
-
modules in section “X
-
CTU utility”
.

Co
nfiguration mode

This mode allows you to configure WCD (see "List of WCD commands

in configura
tion mode
").

To select this mode, you must remove the jumper:

Jumper
XS5
:


remove jumper

In the configuration mode
-

«POWER» LED
will blink one short
shining

every second (0.1 sec.
shining

and 1
sec. without
shining
).

To configure WCD it is necessary to co
nnect
personal

computer through the
COM
-
port (
RS
-
232
interface)

to WCD.

It is necessary to r
un any terminal program (for example

H
yper
T
erminal
)
with

the following parameters:
baud rate
= 38400, data bits = 8, stop bits = 1,
p
arity = none, flow control =
no
ne.

After connection to power supply unit

WCD
begins testing.
Upon completion of testing

terminal program
launched on the personal computer
will display a message about loading of the operating system

in WCD:

Init UART0

Init UART1

UBS scmRTOS+FS (ver.1.1
1) 04.06.2012



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
11

from
23


EXTERNAL DEVICE INTERFACE SELECTION


Selection of interface (RS
-
232 or RS
-
485) for connection to external device is made using jumpers located
on WCD PCB board:


RS
-
232 communication interface selection
:

Jumper P
1:

short circuit (close) pos
itions
1
-
2

Jumper P
2:

short circuit (close) positions
1
-
2


RS
-
485 communication interface selection
:

Jumper P
1:

short circuit (close) positions
2
-
3

Jumper P
2:

short circuit (close) positions
2
-
3


Also it is necessary to set RTS settings of the interface us
ing parameter
<RTS_485> in command SET_COM
in configuration of WCD
(see "List of WCD commands

in configuration mode
").



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
12

from
23


START

OF OPERATION


To turn on WCD it is necessary to connect the power supply to one of the connectors "9 ...
24V


on the
back panel of

WCD

(either using a power supply plug or wires screwed to the terminal block)
. After power

up

WCD en
ters the test mode and launches

the radio channel.
WCD activation ends with "POWER" LED
indication.


In data mode
-

«POWER»

LED will be constantly shining
.

In this mode, the modem allows externa
l devices
to exchange data via
radio channel.

In the configuration mode
-

«POWER» LED will blink one short flash every second (0.1 sec.
shining

and 1
sec. without
shining
).

In this mode
, WCD configuration can be perfo
rmed using

commands
,

described in
section “Configuration” on this Technical Guide
.

In
X
-
CTU

mode
-

«POWER»

LED will blink two short
times

per second (double
shining

every second).

This
mode allows us
age

of

X
-
CTU utility to configure the Zigbee
-
module.

Comp
lete documentation on the used
X
-
CTU utility
can be downloaded from official website:
http://ftp1.digi.com/support/documentation/90001003_A.pdf
.



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
13

from
23


LIST OF WCD COMMANDS

IN CONFIGURATION MODE


Commands can be entered only in

WCD

configuration mode.


RESET



R
ESET

This command performs hardware reset the WCD.


STACK

STACK

This command allows to view stat
e

of used memory

R
esponse:

<Used and free space>

R
esponse
e
xample:


CStack: free and used memory

Process #0: 135 65

Process #1: 138 112

Process #2: 213
87

Process #3: 175 75

Process #4: 156 94

RStack: free and used memory

Process #0: 32 32

Process #1: 26 38

Process #2: 44 20

Process #3: 32 32

Process #4: 38 26



REG

REG

This command allows to view stat
e

of internal
registers

Response:

<state of

internal registers>

R
esponse
e
xample:


Inner registers UBS:

Control

State

00000002

0000000C

00000000

0000004B

Use the receive buffer UART:

UART #1: 0

UART #2: 51



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
14

from
23


LIST ADDR

LIST ADDR

This command allows to view table of addresses of
network subs
cribers, which
can

communicate with
given WCD
.

Response:

<record number> <device address in HEX
-
format>

R
esponse
e
xample:


# AddrModem

________________

0: 00 00 00 00 00 00 FF FF


Each
WCD
in network has a unique address, which consists of 8 bytes (ad
dress is specified in the bottom of
Zigbee
-
module,
also

address can be
obtained

using
X
-
CTU utility

(read more about
X
-
CTU utility
for
configur
ation

of
Zigbee
-
module
s in section “X
-
CTU utility”
)
). If

address of
another
WCD

i
n the network
is
entered

in the
address table

of given WCD
, then

given

WCD
will transmit data
to this WCD
. If
broadcasting
address 0x
000000000000FFFF

i
s entered in
the

address table

of WCD



then
given WCD
will
transmit
data
to

the broadcast
ing

address
.


ADD ADDR


ADD ADDR,<address>

This

command allows to add ad
dress
es

of
other
WCDs

in
subscribers

address table
,

with
which

given

WCD
should c
ommunicate
.

Parameters:

<8
-
byte address of the modem in HEX
-
format>

Command example:


add

addr
,13
a
200407
b
54
f
2


DEL ADDR

DEL ADDR,<number>

This c
ommand allows to remove
ad
dress of
other
WCD

from subscribers address table
.

Parameters:

<record number>

Response
.

Command example:


del

addr
,
2


In order to delete WCD address from subscribers address table c
ommand

"LIST ADDR"

can be used

to
view

wh
ole

table of addresses

and search for
sequence number

of
address
for
deletion
,
it is required to
remember its number and then

using command

"DEL ADDR, <number>"
,

put this

number

as a

<number>
parameter.


WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
15

from
23


GET COM

GET COM,<number>

This command allows to obta
in parameters of
specified COM
-
port.

Parameters:

<
number of

СОМ
-
port
>

Response:

<
typeproc
><
baudrate
><
stopbits
><parity><
RTS_485
>


<
typeproc
>

-

t
here are two types of processes for
the COM port:

1


process

f
or servicing of

external devices

2


process

for servicing
of
Zigbee
-
module


<
baudrate
>

-

COM
-
port
baud ra
te


<
stopbits
>

-

number of stop bits


<
parity
>

-

parity values:

0
-

without parity

check

1


odd

parity

2


even

parity


<
RTS
_485
>

-

232/485 mode selection:

0
-

232
interface

1
-

485
interface

Command example:


UBS>get com,0

1 9600 1 2 1


WCD

has

two CO
M ports:

-

port
#
0


is

an

external COM port

of the
WCD, to which external devices are to be connected

-

port
#
1
-

is an internal COM port

to which
Zigbee
-
module

is connected

Therefore as a

<number>

parameter
it is necessary
to specify value “
0


or

1

.




WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
16

from
23


SE
T COM


SET COM,

<number>,

<
typeproc
>
,

<
baudrate
>
,

<
databits
>
,

<
stopbits
>
,

<
parity
>
,

<
RTS_485
>


Th
is command allows to set parameters of

specified COM
-
port.

Parameters:


<
typeproc
>

-

t
here are two types of processes for
the COM port:

1


process

for servi
cing of

external devices

2


process

for servicing of
Zigbee
-
module


<
baudrate
>

-

COM
-
port
baud rate


<
databits
>
-

number of data bits (5,6,7,8)


<
stopbits
>

-

number of stop bits

(1,2)


<
parity
>

-

parity values:

0
-

without parity

check

1


odd parity

2


even parity


<
RTS
_485
>

-

232/485 mode selection:

0
-

232
interface

1
-

485
interface

Command example:


UBS>set com,0,1,9600,8,1,0,0



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
17

from
23


GET PACKVALUE

GET PACKVALUE

This command allows to obtain
a value for
minimum
size of

bytes in

packets
transmitted

ov
er the
radio channel
.

Response:

<
packsize
>


I
f

value of

<packsize>

is

not equal

to zero
-

then
before sending it

in

radio channel WCD
during
<packtimeout>

milliseconds (see command
s

"GET PACKTIMEOUT" and "SET PACKTIMEOUT")
is
waiting for
accumulation

in
its buffer

of
<packsize>

number
bytes of
data packet

received
from external device

(
with a minimum size
specified in
<packsize>
)
.


If value
of

<packsize>

equals
0
-

then

WCD

will
send data

in

radio channel

at once after
reception of any byte received from

external
device
without
delay
.


SET PACKVALUE


SET PACKVALUE,

<
packsize
>


This command allows to set
a value for
minimum
size of
bytes in

packet

transmitted

over the
radio channel
.

Parameters:

<
packsize
>


I
f

value of
<packsize>

is

not equal

to zero
-

t
hen
before sending it

in

radio channel WCD
during
<packtimeout>

milliseconds (see command
s

"GET PACKTIMEOUT" and "SET PACKTIMEOUT")
is
waiting for
accumulation

in its buffer of
<packsize>

number bytes of
data packet

received
from external device (
with a mi
nimum size
specified in
<packsize>
)
.


If value
of

<packsize>

equals
0
-

then

WCD

will
send data

in

radio channel at once after
reception of any byte received from external
device
without
delay
.

Command example:


UBS>set packvalue,2



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
18

from
23


GET PACKTIMEOUT

GE
T PACK

This command allows to obtain
a value for
timeout

of
COM
-
port

for
waiting
o
f

arrival of
the next
byte in the packet
coming from external device
before
transmitting of the obtained bytes package
over the radio channel
.

Response
:

<
packtimeout
>


B
efo
re
transmitting over the radio channel WCD
within
<packtimeout>

milliseconds
is waiting for

accumulation

of
data packet in its buffer
.
If
during the timeout limit no byte has arrived from
the COM
-
port


WCD transmits obtained data packet
over the radio cha
nnel. If case if some byte has
arrived until timeout is expired


byte is added
to the data packet and again process waits

until
timeout expiration.


SET PACKTIMEOUT


SET PACKTIMEOUT,

<
packtimeout
>


This command allows to set
a value for
timeout

for COM
-
port for

waiting
of

arrival of
the next
byte in the packet
coming from external device
before
transmitting of the obtained bytes package
over the radio channel
.

Parameters:

<
packtimeout
>


Before transmitting over the radio channel WCD
within
<packtimeout
>

milliseconds
is waiting for

accumulation

of
data packet in its buffer
.
If
during the timeout limit no byte has arrived from
the COM
-
port


WCD transmits obtained data packet
over the radio channel. If case if some byte has
arrived until timeout is expire
d


byte is added
to the data packet and again process waits until
timeout expiration.

Command example:


UBS>set packtimeout,50



WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
19

from
23


GET XBEE

GET XBEE

This command allows to get
the

value

of

Zigbee
-
module

version.

Response:

<
version
>


1
-

Zigbee series1

2
-

Zigbee series2


SET XBEE

SET XBEE,

<
version
>


This command allows to
s
et
the

value

of

Zigbee
-
module

version.

Parameters:

<
version
>


1
-

Zigbee series1

2
-

Zigbee series2

Command example
:


UBS>set xbee,1





WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
20

from
23


X
-
CTU UTILITY


X
-
CTU utility
is a Windo
ws
-
based application provided by Digi

company (
http://www.digi.com
)
.


X
-
CTU utility allows easy configuration of
parameters

and reprogramming of the ZigBee
-
modules used in
WCD.


This program was designed to interact with the firmware files found on Digi’
s RF products and to provide a
simple
-
to
-
use graphical user interface to them.


X
-
CTU is designed to function with all Windows
-
based computers running Microsoft Windows 98 SE and
above. X
-
CTU can ei
ther be downloaded from Digi’s w
eb site
.




Complete do
cumentation on the used
X
-
CTU utility
can be downloaded from Digi company official website:
http://ftp1.digi.com/support/documentation/90001003_A.pdf
.




WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
21

from
23


CABLING


Cablings supplied to
gether with WCD include 2 cables:


1.

Cable for connection to
PC


Required a direct
cable (pinout: 2
-
2, 3
-
3, 5
-
5) with connectors DB
-
9F and DB
-
9M on its edges:


Cable connector for connection to PC

(connector type DB
-
9F)

Cable connector for connection to
WC
D

(connector type


DB
-
9M)

2 (RxD)

2 (TxD)

3 (TxD)

3 (RxD)

5 (Gnd)

5 (Gnd)


2.

Cable for connection to PTS

controller


Required a cable with connectors

DB
-
9M on both of its edges and following pinout (1
-
4, 3
-
1):


Cable connector for connection to PTS

(c
onnector type DB
-
9M)

Cable connector for connection to WCD

(connector type


DB
-
9M)

1 (line B)

4 (line B)

3 (line A)

1 (line A)





WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
22

from
23


SUPPLY PACKAGE


Supply package of WCD includes:


Num.

Description

Quantity

1

WCD unit


1

2

Antenna unit (12 dBi amplif
ication)


1

3

Cable for connection to PTS controller (optionally)

1

4

Cable for connection to PC (optionally)

1

5

Documentation

1





WIRELESS COMMUNICATION DEVICE FOR PETROL STATIONS. T
ECHNICAL GUIDE.


Revision

number
:
1.
0
1

Review date
:
03

Jan

201
3

www.technotrade.ua


page
23

from
23


EXAMPLE OF APPLICATION ON PETROL STATION


Following picture shows a configuration of petrol station, where wired connections to fuel dispensers and
ATG system is made wireless instead of wired.

In order to provide control over fuel dispensers each of the fuel dispensers should be connected to WCD

(several fuel dispensers or all of them can be connected to the same WCD).

In order to provide control over ATG systems ATG console (or ATG probes directly) should be connected to
WCD.