University College of Medical Sciences Open General Tender 2012-13 Tender Group Anatomy

licoricehealthAI and Robotics

Nov 14, 2013 (3 years and 11 months ago)

371 views


43



University College of Medical Sciences

Open General Tender 2012
-
13


Tender Group


Anatomy


S. No.

Name of Item

Specification

1.


Container V
ertical
C
ylindrical cap. 220
liters

Container vertical cylindrical cap. 220 liters:


S. Steel Tank with S. Steel lid

Size: L 30”x W 24”x H 30” +6” wheel legs fabricated by 16 gauge surgical stainless steel rustproof sheet. Complete
with handle for easy to transportation. Wheel size: 4”x1 ½ “


2.


Electronic Weighing
balance





Max. capacity : 120 gm, Tare range : 0
-
120 gm



Readability : 0.1 mg



Calibration weight : built
-
in



Calibration : self, fully automatic built
-
in (internal calibration)



Accuracy: Fully automatic internal adjustment temp. controlled



High contrast LED display



Metal housing with high grade chemical resistan
ce



Data interface : RS 232, USB



Built
-
in application program



Shock and overload protection



Operating voltage : 220V/50 Hz



Tender Group


Biochemistry


S. No.

Name of Item

Specification

1.


Photoelectric
Colorimeter



Compact to easy to operate.



Standard gl
ass filter :8



Minimum volume 1 ml



Display 3 digits, Digital LED Display



Wavelength range 400
-
700nm



Output O
D: 0

to
1.99,

%T:

0

to
199



Resolution O.D: 0.01,%T: 1%



Accuracy 0.5%FSI



Detector selenium photocell/ photodiode



Light source tungsten lamp

2.


Tran
silluminator



Combined UV (Dual) and white light combinations.



Edge
-
to
-
edge UV uniformity



Compatible UV Blocking cover



Gel tray (dimensions 21cm X 21cm) preferably with cm marking Molded plastic base


44



3.


Modular vertical gel
electrophoresis and
blotting app
aratus with
programmable dual
mode power supply

Vertical gel electrophoresis system comprising of cooled vertical tank complete with casting base

1.

Ability to carry out electrophoresis in two
or more
gels simultaneously.

2.

Easy to use, easy to assemble and lea
k proof apparatus

3.

Compatible with 2D gel electrophoresis

4.

Casting frames should be as simple as possible with simple clamp closure provision.

5.

Glass plates and combs should be
labelled
with thickness and number of well for instant identification (preferable)
.

6.

Typical SDS
-
PAGE run time should be around 40
-
45 min.

Transfer apparatus

7.

Compatible electrophoretic transfer cell for western blotting

Power Supply

8.

Compatible programmable dual mode
power
supply for both electrophoresis and transfer with provision to run

two or more
systems simultaneously.

4

Double Door
Refrigerator



Gross capacity: 350
-
400 Litres



Vertical



Defrosting system: Frost Free



Doors: 2



Energy efficiency: 4
-
5 Star rating

5

Hot Air Incubator



Made of sturdy d
ouble walled
steel body with good
qual
ity insulation.

Capacity> 300 litres Inner chamber made of Stainless Steel.



Heating element made of high grade chrome plate nichrome wire.



Digital Temp. Controller cum indicator with Accuracy ± 0.5
o
C



Temp. Range
ambient to 100
o

C.




Provision for Air Venti
lation.



Tray (> 3) made of
S. S. Wire mesh.



Air circulation Fan for Uniform Temp



Digital Timer

6

Laboratory Centrifuge



Swing head rotor to include
24x10
-
15
ml tube with adapters for
7
-
10ml &
1.5/2.0 ml tubes



Digital display for time and speed



Maximum spe
ed: 6000
-
8000 rpm



working noise: ≤48dB



High intension PC lid, auto stop when lid is open during running

7

Ultrapure Type


I
Water Purification
System



Integrated Ultrapure water purification system which gives Type II and Type I water and should consis
t of pre filtration unit and
softener, direct ultra pure water purification unit, tank etc.



The quality of water should be suitable for use in HPLC, GC
-
MS and for molecular biology applications.



Flow rate up to 1L/Min



Output quality upto 18.25 megaohm.



Con
ductivity at 25
o
C: 0.05µS/cm



Resistivity, MΩ•cm @ 25 °C 18.2



TOC ppb (µg/l) 1
-
5.



Bacteria count, cfu/ml <1.



Particulates /ml <1



Pyrogens (endotoxin) EU/ml <0.001.



Rnase, ng/ml <0.01.



Dnase, pg/µl < 4.





45




Tender Group


Central Research Laboratory


S. No.

Name of Item

Specification

1.


F
luorescence
M
icroscope With

C
amera

High Resolution Trinocular upright Microscope with digital camera & software
.

1.

Basic stand with LED power supply with uniform Illumination (
90
-
250V
).

2.

Magnification 40x
-
1000 x.

3.

Synchronized light brightness objectives

4.

6
-

Positions motorized nosepiece.

5.

Universal condenser

for easy matching of aperture with objectives.

6.

Eyepice 10x with 22
-
25 mm FOV & Objectives Plan achromat 4x,10x ,Plan fluor 40x , Plan fluor 60x & 100x oil. Also phase
contrast objectives for 10X,40
X and 100X.

7.

Software for Measurements, Annotation, Micron bar.

8.

Trinocular observation tube with Vis/Phot. 100/0, 80/20 & 0/100 light beam splitting facility

to get more flexibility in normal
observation using 80/20. Eyepiece tube inclination at 25 degree
or better.

9.

The fluorescence illumination light path should be of Light trap technology to get a good contrast in the final image.

10.

Turret fluorescence filter holder 4 or more filters.

11.

Fluorescence Intensity Manager (FIM) to protect specimens from photo blea
ching.

12.

Integrated shutter for quick stop of illumination.

13.

Mercury 120/ 130 W illumination for fluorescence with at least 2000 hr lifetime.

14.

Fluorescence filters for UV/DAPI, Blue & Green excitation

15.

System should have facility for phase contrast & upgradable

for Dark field application.

16.

Microscope should have option for LED Based Fluoroscence attachment for future upgradation.

Software should have the following fetures
-


-

Automatic recording of experimental parameters for reference or reloading for subsequent e
xperiments Viewing, organising and
exporting data

-

Full image viewer including annotations and image overlay

-

Adjust contrast, brightness and gamma on every image

-

Intensity, length and area measurements

-

Parallax correction Modular Structure

Compatible Data S
tation.( Branded computer/laptop with atleast i3 processor, 4gb RAM, 500 hard disc along with UPS, 1KVA off line)


DIGITAL CAMERA FOR ABOVE

Scientific

grade High resolution colour digital camera with 5MP camera should have the feature of Fast and ultrasha
rp grayscale Camera
with 2/3", 5.0 Mega Pixel or better. C.CD Camera 14 bit. All the accessories should be from same manufacturer except comput
er.


2.


Atomic Absorption
Spectrophotometer



Fully automated personal computer controlled integrated Atomic Absor
ption Double Beam Spectrometer.



System with Wavelength Range 190


900 nm, with automatic changeover between Flame & Furnace Mode along with Deuterium /
Zeeman background correction



Echelle grating/ Czerny Turner Type/ Diffraction grating used with dual bl
azed and ruling density [RLD (Reciprocal Linear Dispersion)
1.6 nm/mm] or Better



Spectral bandwidths of 3 different types programmable through software using auto slit selection mode.



4 or more lamps position Automatic Lamp Holder with computer controlled
lamp selection, its alignment and automatic optimization of
energy using cooled lamps.



Built in power supply for 2 or more special Lamp to enhance sensitivity.



Selection of single beam for GFA mode.



The system should be integrated for both Flame & Furnace

with built in Atomizer and can be controlled thru software.



The Detector used shall be Solid State Detector/ PMT (190


900 nm) having quantum efficiency.



Graphite furnace System for Trace analysis facilities (sub ppb) with furnace Head, Power Supply (230

Volts/ 50 Hz), and Furnace Auto
sampler (capacity at least 50 Samples) along with 100 vials.



Graphite Furnace Atomizer > 2600

o
C or better.



Deuterium/ Zeeman Background correction for Graphite Furnace.


46





Built in Camera/Optical sensor in Graphite Furnace to

display actual sample introduction and method Optimization.



Total Gas Flow Control System to maintain gas flows (Ratio of fuel/oxidant) at set levels even when subjected to outside vari
ations like
nebulizer adjustments.



Two Burner Head should be supplied;

one for Air Acetylene (100cm) & Other for N2O burner head (50 cm)



Automatic Gas Flow adjustment during change over between air C2H2 and N2O



All safety interlocks like Burner head Interlock, Drain Interlock etc to built
-
in.



Adjustable nebulizer to take ana
lysis with acids, corrosive samples including HF.



Carbon filled PPS Spray Chamber to analyze all types of samples, has high mechanical strength and fast drainage characteristi
cs



Fully Computer controlled Spectrometer for all major accessories including Gra
phite Furnace, Burner Heads, Auto sampler etc under
software control



Integral Furnace Auto sampler with Graphite Furnace for 50 or more samples delivery up to 50µl with increment of 0.1 µl, auto
matic
replicate analyzer, automatic replicate analyzer. Auto S
ampler should allow dilution.



Intel Core i5 processer PC (HP/Dell), RAM = 8 GB, TFT Color Monitor = 19 inches, DVD Writer/Player, Two Speakers, Graphic Car
d
with Licensed Microsoft Operating System (latest ) with backup copies in DVD/ CD.




Licensed Windows

Based Software for AAS system functions including control of all accessories, both of single element or multi
-
elements methods for Flame/ Graphite Furnace as well as for Data Processing & Data acquisition of AAS System with original co
py in
CD/DVD with pr
ovision of future up gradation should be provided.



Printer HP Color Ink Jet Printer.




Auto parameter selection for method development, automatic selection of stored methods, automatic selection of flame conditio
ns.
Graphite furnace and MHS/HVG Techniques,
Burner head position is stored with method, auto optimization of flame, online sensitive
context help, and user selectable statistics for SD/ Percentage RSD, built in reporting user format, mouse operation, and sof
tware
available in CD form.



Gas Pressure R
egulators: One each



Double Stage Gas Pressure Regulators with Stainless Steel Diaphragm, for Ultra High Purity Grade gases each for Acetylene, Ni
trous
Oxide and Argon with necessary SS tubing and fittings for connecting these to Gas Cylinders.



Vendor shou
ld quote MHS/HVG for analysis of hydride forming element.



Vendor should quote Individual coded HCL Lamp Zn, Co, Cu, Al, Ni, Ca and Mg



Special lamp for As, Hg, Cd, Pb.



Vendor should quote Indian component part like C2H2 gas Cylinder with regulator, N2O gar
Cylinder, Ar gas cylinder with regulator,
Fume Hood (SS) with fan and fitting hardware required for quoted AAS unit.



NIST traceable Standards for each element separately 100 ml (1000ppm) each.



Compatible 10 KVA on Line UPS with at least 30 min back up for

Flame and for Furnace mode.



Vendor should quote Following Imported Items:



N2O regulator with Heated Assembly system.



Air Compressor Oil Free, Noise less, with air purifiers and moisture trap Circulating Refrigerated Chiller


3.


G
as
C
hromatography

-

M
ass

S
pectrometer

Gas Chromatography



Fully automatic computer controlled GCMS with programmable electronic control and having capability of qualitative and quanti
tative
analysis



Should have inbuilt GC main frame with Split / Split less Injection port GC wit
h Pneumatic Flow Control capability Accommodates up to
two capillary columns



Operating temperature range suitable for all columns and chromatographic separation



Temperature Range: Ambient +4°C to 450°C (Programmable up to 450 °C) heat up time should be >5
min.



Temperature Programming supports > 9 oven ramps or better



Setting : 1 deg C/min



Temperature Ramp Rate: 120 °C /min, 0.1 °C /min increments



Should Equipped with a cooling system, that enable the reduction of cool down time from 450 deg C to 50 deg
C <5 minutes



Software Pneumatic Control up to 0.01psi or better


Mass Spectrometer



Mass range 1.5


1090 amu in 0.1 amu steps


47





Scan speed >12,000 amu.



Ionization modes: Electronic Ionization(EI) and Positive and Negative Chemical Ionization (CI)



Ion sourc
e temp: upto 350

o
C for better sensitivity for active compounds and should be programmable transfer temp 100

o
C to 350

o
C.



Mass analyzer should be based on Quadrupole with high ion transmission efficiency.



Quadrupole temp: optimizable as per the system req
uirement.



Vacuum Compensation and automatic leak testing with MS



The detector should have provision to reduce the random noise that occurs with ion transmission, improving the S/N ratio



Scan sensitivity
Using helium as carrier gas

S/N Ratio in simultaneou
s SIM and SCAN mode



EI full scan specs

1 µL injection of 1 pg/µL OFN at S/N ≥ 600:1



PCI full scan specs

1 µL injection of 100 pg/µL benzophenone at S/N ≥ 600:1



NCI full scan specs

2 µL injection of 100 fg/µL OFN S/N ≥ 1000:1


Columns



Capillary Column DB
-
5, 30 mt (or equivalent phase)



Capillary Column DB
-
WAX, 30 mt (or equivalent phase)



Capillary Column DB
-
1, 30 mt (or equivalent phase)

Head Space Auto sampler



With transfer line/direct injection technique



With at least 40 vials capacity or more.



Entire sy
stem heating from ambient up to
300

o
C in increments of
1
o
C

Vial temperature 50

o
C



250

o
C.



Overlapped Thermostatting (Vials) 10



Transfer Line temperature
50

o
C



300

o
C



Operated through GC Software



Injection volume linearity be 99% correlation and Area
Reproducibility ASDA 3%



Injectors should be either do single or simultaneous injections for both injection ports.



Includes all standard accessories like interface cable, reducing union, HSS Vials 22 ml with 20 mm round top, Crimps Caps, Si
licon
Rubber/T
eflon face septa, Hand Crimper, De
-
capper etc


Auto Injector



Sample vial
Glas
s

construction
,

1.5mL
,

scre
w

top
,

T
eflon
-
coate
d septum. Should be supplied with minimum 100 vials capacity
with septum & caps



Priorit
y

sample injectio
n

ca
n

b
e

i nj ect e
d

duri n
g

a

s
ampl
e

sequence
,

and t hen

th
e

sequenc
e

ca
n

b
e

resumed.




Pneumatic controls



Electronic pneumatic controls should be integral part of injector and detector modules No extra tubing and wires should be ne
eded to
operate electrical valves, and deliver carrier, d
etector and make
-
up gases to injectors and detectors. The digital carrier gas controller
should allow operating in constant and programmed flow and pressure modes.


Injectors (Two Numbers)



Split / Split less capillary Injector



Suitable for all capillary co
lumns (50 pm to 530pm id)



Spilt less mode for trace analysis



Temperature Range 450°C



Split Ratio Setting Up to 1:900 (1 / 1 ratio increment)



Sample Volume 0.1 µl to 8.0 µl; 0.1 µl steps



Programmable Capillary Injector (OCI/PTV)



Programmable Capillary Inj
ection Unit. Should support the analysis of compounds with a high boiling point (straight
-
chain
hydrocarbons with 100 carbon number)



Modes of operation : Spilt/Split less, temperature ramped Split less



OCI/PTV and Spilt/Split less capillary injectors with
built in pneumatic Control thru software for digital setting of septum purge gas as
standard


48





Digital Split Ratio Setting Up to 1:9,999 (1 / 1 ratio increment)



Temp. range : Room temp + 5 oC to 450 oC in steps of 1oC



Heating rate : 50oC to 450oC within 3 mi
nutes



Cooling rate : 450oC to 50oC within 5 minutes



Heating program: max. Heating rate120 oC /minute.



Should be configured with Back Flush option.



For 2 way split, for splitting flow between FID & MS detector

Flame Ionisation Detector



Type


:High sensi
tivity auto
-
ranging



Temp. Range


:Up to 450oC in steps of 1oC



Detection Limit


: 3 pg C/sec or better.



Linear Dynamic Range

:10
6



Suitable for both capillary & OCI/PTV column application; totally software controlled



Detector gas is controlled electr
onically by pneumatic Control thru software



Fast Automatic Flameout detection and efficient automatic re
-
ignition

Turbo Molecular Pump



Vacuum System
should be with turbo molecular pump having capacity of 250 L/min
, with air
-
cooled high vacuum pump, with c
ontrol
and safety interlocks integrated into the system.

Library



Latest Edition library (NIST & Wiley separate library ),


Software

The software should be a single point control of GC
-

MSD system and its modules with an assistant bar showing operating p
rocedures
graphically and a wizard function that helps enter complicated parameters. These make it easy for even first
-
time users to use the software. In
addition, should be controlling pretreatment accessories, such as headspace sampling unit, the softwar
e should allow continuous automatic
operation, while using self
-
diagnostic function of the software validation assistance. If a data problem occurs, the analysis can also be
automatically stopped to prevent wasting precious samples. Since measurement param
eters and data analysis parameters can be controlled
using a single method file and data files include instrument history information, it is capable of supporting GLP compliance
and other
requirements. Operating System

should be

Microsoft Windows 2000 / Wi
ndows XP / Windows Vista. Should have feature of Automatic
Adjustment of Retention Time, creation of Automatic SIM table as standard software feature. Also should have the library sear
ch feature like
Similarity search, Similarity search with Retention inde
x, It should also have features for data acquisition, control, chromatographic data
evaluation and reporting sequencing



Accessories



Suitable On
-
line UPS with 60 minutes back up, for GCMS and HS system.



Filled Helium, Nitrogen, and Hydrogen Gas Cylinders
& Zero Air Cylinder with regulators for the operation of GCMS with all above
accessories
.



Gas purification System for all gases



Complete Gas station for connecting between Gas Cylinders & GCMS.



Intel Core i5 processer PC (HP/Dell), RAM = 8 GB, TFT Color Mo
nitor = 19 inches, DVD Writer/Player, Two Speakers, Graphic Card
with Licensed Microsoft Operating System (latest ) with backup copies in DVD/ CD.




Licensed Windows Based Software for system functions including control of all accessories, as well as for Da
ta Processing & Data
acquisition of System with original copy in CD/DVD with provision of future up gradation should be provided.



Micro Liter Syringes



All essential spares and consumables required for the satisfactory operation of GCMS for at least 3 years

should be offered


4.


H
igh Performance Thin
Layer Chromatography
(HPTLC)

S
A
M
P
LE
APPLICATION

D E V I C E

(
S
pot

&

B
a
nd)



Automatic,



PC Controlled,



For analytical as well as preparative work.

P
L
A
N
A
R

CHR
O
M
A
T
OG
R
A
P
H
Y

SYSTEM

MANAGER


49



Pla
n
a
r

c
h
r
o
m
a
t
og
r
a
p
hy
s
y
s
t
e
m m
a
n
a
g
e
r

so
f
t
w
a
re


CHR
O
M
A
T
OG
R
A
M

DEVELOPMENT

D E V I C E S



Fully automatic with humidity control,



Plate size: 20X20 cm and 20X10 cm and 10X10 cm,



Software controlled,



The activity and preconditioning of the layer, chamber saturation, developing distance and final f
\
drying can be pre
-
set and
automatically monitored.


P
R
O
F
ESS
I
O
N
A
L
PHOTODOCUMENTATION

SYSTEM

T
L
C

V
is
ua
lis
e
r


Q
U
A
N
T
I
T
A
T
IV
E

M
E
A
S
UR
E
M
E
NT

&

D
A
T
A

H
A
N
DL
I
NG



Computer controlled
T
L
C

S
c
a
n
ne
r,



Scan speed: 100mm/Sec @ 25µm resolution,



Automatic spectrum scanning,



A
utomatic quantitative measurement by absorbance and fluorescence.



D2, Hg, W Lamps



Wavelength range: 190
-

900nm




W
i
t
h

q
ua
n
t
i
t
a
t
i
v
e

e
v
a
l
ua
t
i
on


AUTOMATIC TLC SPRAYER

Pneumatic, cordless, using rechargeable batteries, spray heads, bottles of 50 or 100 ml atta
chable.

Automatic TLC Plate Coater


Fully automatic, floating slurry hopper, plate sizes 20 x 20 or 20 x 10 cm

TLC / HPTLC PLATE HEATER



igital thermometer, temp range
25

to
200
C temp;



Stain resistant glass top

IMMERSION DEVICE FOR DERIVATISATION



Suitable for 20 x 20 cm & 20 x 10 cm plates;



Universal plate holder clamp;



Dipping speed
-

30 mm to 50 mm /sec.,



Variable; Dip time
-

1 to 8
secs. + indefinite.



Ribbed and narrow dip chambers for low volume of reagent.

5.


Lyophiliz
er

Chamber made of stainless steel

with Clear acrylic

Cold Trap lid.

Trap Chamber Volume :
Not less than
6

liters

in 24 hrs

Lowest Temperature :

-
80ºC

Drain :

S
ilicon hose

Defrost :

Manual ;
Display :

LED / 0.1ºC increment


Manifold for Lyophilizer


6 Port


1 set

Stainless Steel Manifold with 6 X 3/4” Individually valve controlled Manifold Ports with Rubber Valves to accommodate
Ro
und Bottom Flasks, Ampoule Manifold etc


50




Vacuum Pump


100Ltrs.

High Vacuum Pump: Double Stage.

Pump Capacity : 100 ltr

Fitted with Ballast Valve (to avoid undesirable Condensation) and Anti Suck Back Valve (to avoid oil rush to system.)


Mini Speed

Vacuum Concentrator

Rotor :

2.0ml x 20 hole (Anodizing)

Speed Control :

0


2000rpm ;
Heat Control :

Amb. +5ºC
-

+65ºC

Vacuum pressure gauge:

0


76cm Hg.

Chamber :

SUS with Teflon coating;
Lid :

Clear acrylic lid

Speed :

Max.2000 rpm ;
Vacuum Concentrator :

Id
-
10mm / od
-
19mm

Dimension :
W215 x D380 x H230mm.
Weight :

about 12kg

6.


Flash Chromatography
Apparatus


Automated and integrated Flash Chromatography System consisting of Gradient Pump, Column Holder, UV Detector and Fraction Col
le
ctor as
per following technical/operating specification.


A : Gradient Pump Flow

Min
-

1.0ml/min ;


Rate

Max
-

150ml/min.

Pressure Max: ≥100psi


Solvent Lines

Independent Four solvent , quatro
-
binary gradient capability


wherein it should be possible to use all the four solvents in


binary combination in a single run.




Sample loading

Provis
ions for Liquid and solid loading on cartridge. Bulk media


loading inside the cartridge and outside the cartridge.

Solid: 10mg
-

30g

Liquid: 5ml
-

35ml


B : Interface

System should have space
-

saving, touch screen controll
ed


graphic user interface with Chromatogram storage, processing


and retrieving facilities Window XP operating system.


Columns

Suitable cartridge columns for sample from 100mg to


30g.Cartridge construction material should
be USP Class VI


compliant.



Should include Normal silica,
Gel filtration
C18 and ion exchange columns of



4g, 12g, 20g, 40g. Columns should be reusable and openable. Starting kit of normal phase and
reverse phase columns should be pro
vided along with system.


Real
-
time method change

Change solvent composition, flow rate, fraction settings

facility

during purification and running condition.

Automated method

Facility to create accurate gradient methods based

on entered

creation

TLC data. The software must have a gradient optimization


51




feature which converts a linear gradient method to solvent
-


saving step gradient method.


Cartridge and sample load

List of column cartridge
s with maximum recommended

recommendation features

sample load under gradient elution

Sample loss prevention

Sample

loss prevention feature and alarms and solvent management.

C : Fraction Collector

Broad fractions rack capacity t
o collect minimum 80


fractions & can be enhanced further if required. Two set of each 20 and 50 ml fraction collection
tube along with fraction collection rack should be provided with main system.


Ability to add and remove fractions racks
during the run



Detection

Variable, wavelength detector (200
-
400nm preferably


with accuracy ±0.5nm). Broader range (200
-

800nm) detection limits may be preferred.

Collection

Should be able to communicate (send and receive sign
als)

etc.) with a third party detector
(Evaporative light scattering, RI etc.) and fractionate on the received signal. Integrated XY fraction
collector should have choice of preset size and self define configuration.




System should be independent to use a
ny make cartridge.



Columns should be reusable and open able.



Optional items: ELSD detector should be quoted with the system optionally.



AMC for 3 year should be quoted optionally.

7.


Double beam UV
-
VIS
S
pectrophotometer

TECHNICAL DESCRIPTION

CONFIRMED SPEC
IFICATION ( Critical Spec is not allowed)

Principle

UV/Vis spectrometer with PC control. Preferably with provision for measurement of small
volume.

Construction

Solid Aluminum chassis/ equivalent for thermal and vibration stability

Optics

Double beam
( separate sample and reference cell holder for accurate measurement) sealed,
quartz coated, lens free system, double monochromator


Grating

Concave holographic grating with 1000 lines/mm or better.

Sources

Pre
-
aligned deuterium and tungsten
-
halogen la
mps with automatic switch over

Wavelength Range

190


1100 nm

Stray Radiation/Light

0.007 %T at 220nm(NaI) or better.

Wavelength Accuracy

Minimum +/
-

0.1 nm at D2 peak, 656.1 nm or better.

Wavelength

Reproducibility

Minimum +/
-

0.06 nm ( 10 measurem
ents at 656.1 nm) or better.

Band
-
pass/Band width

Minimum 3steps( 0.5 to 2 or better)

Photometric

Accuracy

+/
-

0.002 A at 1A or better.


Photometric

Reproducibility ( at 1A)

0.002 A ( MAXIMUM DEVIATION OF 10MEASUREMENTS) or better.

Photometric Stabili
ty ( at 1A)

0.0001 A/h (at 500 nm) or better.

Baseline Flatness( 1nm slit)

±

0.002 A or better.


52



Photometric Noise Level at
500nm(1nm Slit)

0.00007 A RMS or better.

Standard Software

Applications


Scan, Time Drive, Wavelength Programming, Concentration,
Bio Assay, Kinetics, Oligo Quant,
Validation, Report Builder, Arithmetic etc. should be included as standard feature of the s/w.

Standard Accessories

Suitable quartz cuvette for 700ul, 1.5ml, 3.5 ml ( one pair each), 10MM.

Optional accessory:

For enzyme
tic kinetics 1+1 peltier temperature controller with water circulator for a
temperature range 20
-
60C

Local Accessories

Suitable branded PC
-
printer
.


8.


Multimode Reader

Modes:

Quadruple

grating

monoch
r
omator

for

maximum

flexibility

and
ease

of

use



Absorb
ance (Monochromator),




Fluorescence Intensity (Monochromator based),



Time Resolved Fluorescence



Luminescence

Range:



Absorbance: 230


1000nm (Monochromator with 1nm increment).

Resolution:
not less then 0.001 OD



Provision for automatic Pathlength correcti
on



Both cuvette and plate option (optional)




Fluorescence Intensity: 250


700nm (Double gr
ating monochromator Top and
Bottom optics 1nm increment).



Luminescence: 300


700nm.



Time resolved fluorescence: 200


700nm.



Machine should be able to read : 6, 12,

24, 48, 96 well plates and Up to sixteen 2μL samples can be run at one time for direct nucleic
acid and protein quantification



Reading Modes: Endpoint, Kinetics & spectrum.



Light Source: Xenon Flash Lamp and dichroic mirrors.



Temperature control: Four zo
ne temp. Control RT to 45ºC.



Shaking:
Linear, Orbital and Double
Orbital.



Software: Compatible software for automatic data reduction and calculation
.

Branded Computer with printer and UPS.


9.


G
el Documentation
System

It should have:

Camera
:



1
6

bit monoc
hrome cooled CCD

(A/D)

camera, with


8
Megapixels resolution.



Cooling:

Two stage peltier cooled.

Absolute and regulated
.

-
28ºC ( From Zero) or
-
51ºC (from Ambient).




Pixels Resolution


3326 x 2504



Gray Scale


65,536



Zoom


Motorized optics for setting the zoom
.

2
4



7
0

mm
,

f
2
.
8

zoom le
ns.


Darkroom
:



Motorized 5 position emission filter wheel.



Filters


Green

(
SYBR Green/GFP/Fl
uorescein); Red (Etbr/Texas Red);



Gold (
SYBR Gold,SYBR Safe,SYBR Orange
). All the filters should be standard supply
.



Software controlled overhead diffused

Visi
ble



Blue and 365nm UV (Epi UV), white light( Epi white) and system
power



Software controlled, fold down ultra thin white transilluminator.



Multiple height adjustable chemiluminescence sample plateform.


53





Pull
out transilluminator tray,
(
Any benchtop t
ransillu
minator can be fitted over this).



Transilluminator power should be

software controlled.



Unique UV protective viewing window to visualize gel and to compare gel without opening darkroom door.



Transilluminator
,
Single

Intensity. Wavelength range:

254
nm,
302
nm, &
365nm
.

W
avelength can be switched from
one to another with the help of knob
.
.20 x 20 cm Filter
.



Software: Image
Acquisition and Analysis
.



S
uitable Branded Computer:



Config
.




3
60 GB HDD,
2
GB RAM, 1
8.5
” Monitor, Mouse, Keyboard and Suitabl
e B/W Laser printer(HP1007) or
equivalent

andwith branded antivirus for entire duration of warranty.


10.


Autoclave

1.

Capacity 25 Liters (approx).

2.

Sterilization temperature 121/134
o
C

3.

System should b
e hydraulic tested up to 40 PSI
, provided with heating elemen
t which are easily replaceable.

4.

System should have steam lined construction, outer body made up of mild steel finished with paint, inner chamber made up of
stainless steel.

5.

System should also be fitted with pressure guage, stem released cocks, spring loade
d safety valve etc.

6.

System should be fitted water level indicator to indicate the level inside the boiler.

7.


System should be fitted with paddle lifting device to open or to close the lid with the help of paddle

11.


Microprocessor
controlled class II, Type
A
2 Biosafety cabinet



Micro processor controlled class II type A
-
2 bio safety cabinet



NSF 49 certificate to be provided along with biosafety cabinet.



Constructed of single sheet stainless steel preferably ≥16 gauge thickness, type 304 pressure tight design.



Metal frame HEPA filter should be 99.995% efficiency on 0.3 micron.



HEPA filter must start from 1 edge of cabinet to order is of cabinet without any

gap between HEPA filter and cabinet body.



Sound level cell be no more than 63 dbA



Fluorescent lighting cell provide 100 to 120 foot
-
candles on works surface..



Air velocity from the supply filter cell average 55 to 65 FPM (.28 to 033m/s)



Air flow system

must be zero leak.



Air flow should be 70% re
-
circulated and 30% exhaust.



The system preferably having dual blower motor.



Front glass should be sliding



System should be with one gas service valve and two electrical outlet



It should have audible window
alarm, Armrest



Work access opening in flow velocity 8
-
10 inch opening.



Blower speed should be electronically regulated



It must have UV light and base stand



Dimension


external


5 feet x 4 feet x 2.5 feet (HxWxD) approximately


12.


Media Filter Assembly

Media filtration is a consist of :



Vacuum pump (oil free diaphragm type )



Glass filtration assembly ( 2 Sets)



Silicon hose



Filter forceps



Fg50 Protection filter



Membrane filter set for 500 filtrations




54



13.


Liquid Nitrogen
Container



Aluminum body ( prefer
ably)



Capacity 40 L (Approx)



Narrow neck design



Lockable cover (preferable)



System must have minimum static evaporation loss,

~
0.5 L/

day (
approx)
, and longer static holding time
~
60 days



No of canister 12
-
15

14.


Automated cell counter
and cell viability

analyzer



Easy to handle Automated cell counter and cell viability analyzer:



Counting time 3
0 sec



Cell concentration range 5 X 10
4
-
1 x10
7
cells/ml



Sample volume
~
10µl



Data storage facility



Slide/ strips and reagent for 1000 assay

15.


Thermostatic Orbita
l
Shaker



Rugged thermostatic orbital shaker suitable for ELISA plates, beakers and tubes.



Size of working platform
30
-
35 cm X 20
-
25 cm.



Temperature range should be between ambient + 5
o
C to 60
o
C, with an accuracy of +/
-

0.1

o

C



Variable platform rotation s
peed with range of 50
-
5
00 rpm.



System shou
ld have a timer for 1min
-
24 hrs and provision for continuous operation up to 24 hrs



Individual LCD display for time, temperature and RPM.



Sound alert on completion.

16.


CO2 Incubator Air
Jacketed



Capacity ( Liters)
~
170L



Shelf : At least four with facilities for quick cleaning



A
ir jacketed with stain less steel inner chamber



Facility for high temperature disinfection



Easy to use HEPA filtration system / similar facility for de contaminated CO
2

supply



Temperature ra
nge : Ambient
+
5
0

C
-
60
O
C with independent over heating protection , temperature uniformity ± 0.35
O
C at 37
O
C



CO
2

range : 0


20 %,
CO
2

sensor infrared



CO
2

rate <5 minute



LED Display and alarm system



Two CO 2 cylinders with connecting valves & suitable

voltage stabilizer.


17.


Bench
-
Top
Flowcytometer Sorter


1.

BENCH TOP FLOWCYTOMETER WITH AIR COOLED SOLID STATE
488 nm

LASER,
633 nm

LASER, 405nm LASER AND 561 nm
LASER. ALL LASERS & THEI R EXCI TATI ON AND COLLECTI ON OPTI CS SHOULD BE PRE ALI GNED.



2.

THE SYSTEM
SHOULD HAVE FIXED OPTICAL ASSEMBLY OF LASERS UPON THE CUVETTE FLOW CELL TO ENSURE FIXED
ALIGNMENT. THE EXCITATION AND COLLECTION OPTICS OF ALL LASERS SHOULD BE FIXED REQUIRING NO ALIGNMENT TO
BE DONE BY OPERATOR.


3.

SYSTEM SHOULD BE CAPABLE OF USING AT LEAST

4 LASERS SIMULTANEOUSLY FOR WIDER CHOICE OF DETECTION
COLORS & LESS USE OF COMPENSATION. SYSTEM SHOULD HAVE MINIMUM FOUR BEAM SPOTS WITHOUT ANY
CUSTOMIZATION WITH THE BASE INSTRUMENT.



4.

THE SYSTEM SOFTWARE SHOULD BE CAPABLE OF ESTABLISHING BASELINE SETTI
NGS OF SYSTEM PERFORMANCE AND BE
ABLE TO ADJUST FOR INSTRUMENT VARIABILITY THEREBY AUTOMATING INSTRUMENT SETUP LEADING TO CONSISTENT &
RELIABLE RESULTS.



5.

THE SYSTEM SHOULD HAVE 7, PREFEREABLY 9, FLUORESCENCE (11 PARAMETERS) MEASUREMENT CONFIGURABLE UPTO

18 FLUORESCENCE (20 PARAMETERS) MEASUREMENT SIMULTANOUSLY.



55



6.

THE SYSTEM SHOULD ALSO HAVE SOFTWARE ADJUSTABLE SAMPLE INPUT AGITATION AND TEMPERATURE CONTROL.


7.

THE SYSTEM SHOULD HAVE SOFTWARE ENABLED AUTOMATION TO SIMPLIFY DROP DELAY DETERMINATION.


8.

THE SYST
EM SHOULD HAVE LESS THAN 90 MESF FITC AND LESS THAN 35 MESF
-
PE.


9.

THE SYSTEM SHOULD BE ABLE TO ACQUIRE AT LEAST 70000 EVENTS/SECOND.


10.

THE SYSTEM SHOULD HAVE NOZZLES (70 um/100um & 130 um) WHOSE REMOVAL AND INSERTION SHOULD BE POSSIBLE
WITHOUT REALIGNING TH
E OPTICS OF THE FLUIDIC SYSTEM. THE SYSTEM SHOULD BE CAPABLE OF SORTING SPEED 50,000
EVENTS/SECOND. IT SHOULD HAVE 2 WAY & 4 WAY SORTING.



11.

THE SYSTEM SHOULD BE CAPABLE OF SAMPLE INPUT FROM MICROTUBES, 12 x 75 mm, AND 15 ml TUBES.


12.

THE SYSTEM SHOULD HAVE

BUILT IN SORTER CAPABLE OF TWO
-
WAY AND FOUR WAY SORTING. THE SYSTEM SHOULD BE
ABLE TO PROVIDE VARIOUS SHEATH PRESSURE OPTIONS FROM 5


75 psi.



13.

THE SYSTEM SHOULD HAVE OPTION OF AUTOMATIC CELL DEPOSITION UNIT (ACDU) WHICH ALLOWS FOR SLIDE AND PLATE
SORTIN
G INTO 6,24,48,96 AND 384 PLATES.



14.

THE SYSTEM SHOULD HAVE PROVISION FOR FUTURE UPGRADATION WITH AIR COOLED SOLID STATE 375nm/445nm LASERs
UP TO MAXIMIMUM OF 6 LASERS. (THESE LASERS SHOULD BE QUOTED OPTIONALLY)



15.

DATA MANAGEMENT SYSTEM: SERVER LEVEL PC WOR
KSTATION WITH AT LEAST PENTIUM4 @ 2.66 GHz, 160 GB HARD DRIVE,
DVD/CD
-
ROM REA /WRITE COMBO RIVE, FLOPPY RIVE, TWO 19” LC MONITORS AN COLOR INKJET PRINTER.


16.

.THE SYSTEM QUOTED SHOULD BE A BRAND NEW ONE AND AN UNDERTAKING IS TO BE GIVEN FOR THE SAME.


17.

AL
L TECHNICAL SPECS CLAIMED SHOULD BE SUPPORTED BY TECHNICAL LITRERTURE AND DOCUMENTS.


18.

THE COMPANY SHOULD PROVIDE AFTER SALES APPLICATION SUPPORT AND TRAINING TO THE USERS.


19.

The system should be provided with 5 years comprehensive warranty (including all sp
ares) and should be quoted with appropriate online
UPS of 5 KVA With 30 min back
-
up.

18.


Gradient PCR with 96
wells



Gradient Thermal Cycler with Peltier heating and cooling based system. Power Supply: 220
-
230 volt, 50

60 Hz



Should have block for 96 x 0.2ml
tubes with an option of dual block of 2 x 48 x 0.2ml which can be independently controlled.



The dual block should also have gradient capability which can be independently controlled for both the blocks.



Should have a maximum ramp rate of 5
0

C or more/seco
nd and average ramp rate of 3.0
0

C/sec or more.






Should have a temperature range of 0
-
100
0

C



Should have a temperature accuracy of ± 0.2
0

C or less



Should have temperature uniformity of ± 0.4
0

C or less well to w
ell within 10 seconds of arrival at 90
0

C.



Should have a gradient range of 30
-
100
0

C and use dynamic ramping for gradient.



Should have a LCD display and have USB ports.


56





Should have a memory of >1000 programs with further expansion through a USB Flash dri
ve for transfer of files.



Programmable, power
-
saving auto standby option when instrument is idle.






Should be licensed for research.



Should be supplied with 1 KVA online UPS with one hour power back
-
up



Original company literature from principal company, manufacturer must be supplied; clearly
verifying all specifications.


Tender Group


Physiology


S. No.

Name of Item

Specification

1.



Electromyography


EMG/NCV/EP System


Fully computerized system that works under Windows 7 platform


Having


4 channel

high quality amplifier, CMRR must be gr
eater than 106 dB for better signal quality, Common Mode Input impedance must be
greater than 1000 M Ohms, Noise level


should be less than 0.6 micro volts. The electrical stimulator should have Single, Double, Train
stimulation modes. System should have 1
6 bit A/D converter. Low cut filter to be varied from 0.01 Hz
-

500Hz. High cut filter to be varied from
10Hz
-

20KHz. Sensitivity: 1
-

500 µV/div. Amplitude calibration 1 micro volt to 10 milli volt. Electrode to skin impedance check: 2 to 20 K ohm

EMG sof
tware

including Free running EMG, Signal Triggered EMG, Multi
-
MUP Analysis, TA Analysis, Peak
-
ratio analysis & EMG event
recorder

Nerve Conduction studies
: Motor Nerve Conduction, Sensory Nerve Conduction, F
-
wave, H
-
reflex, blink reflex, Repetitive Nerve
S
timulation.

Autonomic functions:

Sympathetic skin response / Galvanic Skin Response, R
-
R Analysis & R
-
R Valsalva test.

Evoked Potentials
: Somatosensory Evoked potential including Upper, Lower and dermatome SEP, Auditory Evoked Potentials with
clicks, tone,

burst, pips, half sine, full sine, ABR, MLEP, LLEP, CNV & P300 with patient reaction switch, Visual Evoked potential with
pattern monitor (22” LE Monitor)

System requirements
: Latest specification desktop computer that works under Windows 7 platform must

be supplied with minimum
500GB harddisk, 2GB RAM, 19” TFT monitor, UPS, Printer & Imported trolley from manufacturer. Must be supplied with triple
-
key foot
switch for control of the software. Should be able to generate report without the need of MS office
.The software should have option of
having Normative data for computation and online comparison with test values. The software to have facility to quickly review

the complete
summary of the all the acquired traces and tabulate the results without need to g
o in each and every test protocol. The system should
provide control knobs for sensitivity, gain, marking cursors, pulse width etc.

Standards
: System must comply with international quality standards such as FDA.

EMG/ EP Accessory Kit
must contain:

1.

50 Nos.

of Gold or silver/ silver chloride Disc Electrodes

2.

Ten 20 Conductive paste


100 Nos., Nuprep gel


20 Nos.


57



3.

10 boxes of 37 mm disposable Platinum EMG concentric needles.

4.

Disposable surface electrode 100 Nos.

5.

Cable for disposable needles


2 Nos, Ring ele
ctrodes pair


5 Nos.

6.

Wrap Around Ground Electrode


3 Nos.

7.

Felt Pad Stimulator, Adult


3 Nos.

8.

Lead goggle

9.

Head phones for adult and kids.

2.



Body Composition
Analyzer


1. Body Composition Analyzer should be designed to calculate regional body compositio
n

2. This machine should be based on the latest statistics method DAX, which should analyzed human body composition including f
at, weight,
-

BMI (Body Mass Index), none
-
fat and other health indicators through multi
-

frequency bio
-
electrical impedance analy
sis method, also called
MFBIA.

3. It should have measurement method of multi
-
frequency bioelectrical impedance with 50 kHz, 100 kHz, and 200 kHz frequencies

4. It should have 8 point tactile electrode system for measurement

5. It should measure right arm,
left arm, body, right leg, left leg

6.It should have following output parameters.Pritein, Osseous/non
-
osseous Mineral, Body fat Mass, Skeletal Muscle Mass, Soft Lean Mass, fat
free Mass, Weight BMI Percent Body fat, Waist
-

Hip ratio (WHR), Body Balance, B
ody Strength, Health Diagnosis Target Weight, Weight Control,
fat Control, Muscle Control Fitness Score Obesity Degree Impedance of Each Segments & Frequencies

7. It should have control have panel of True colorful touch screen

8. It should consume the powe
r of 100
-
240V, 50/60Hz

9. It should have sturdy base for analysis of parameters of bariatric population

10 it should have detachable electrodes with cable from main machine.

11. It should have wheels as base for easy transport

12. Main machine should also
have the provision of both internal thermal printer and external DeskJet printers

13. It should internal memory to store patient/Subject data with name.

OPTIONAL:

1. Provision for connection with digital scale should also be there

2. It should have option
to increase the memory and data transfer with PCMCI Card.

3.


Precision Spirometer




For the measurement of:

* Spirometry & Flow Volume Parameters,

* Maximum Ventilation Volume,

* Lung Volumes & Sub
-
divisions,

* Pre & Post Bronchodilator comparison,

*

Broncho Provocation Test Software.

Incorporates Precision heated Pneumotachograph :


Minimum Flow Range: + 0


14 L/Sec (Linear)

Should measure user upto 20 Litres/Sec (Range Selectable),


Resistance: 0.5 cm H2O/L/Sec.

Accuracy < 3%


(Should meet Cri
teria of ATS Standards),


58





Parameters should be measured with highest accuracy & reproducibility

and accuracy not effected with Humidity, Moisture & Water droplets.


Should incorporate Electronic Barometer & Temperature Sensors,

for Automatic BTPS

Correction.


Overlaying of previous test curves for comparison.


Real Time Flow Volume and Volume Traces on Computer Screen.


Capability to select and modify predicted equations.


Facility to interface for desktop/Laptop computer.


System software shou
ld be based on Windows XP Operating System.


Should be supplied with Computer Interfacing package, Cables, Software,

3 Litre Calibration Syringe, Standard accessories & Manual.


Additional Accessories: Pneumotach Screens (05 Nos), Pulmonary Filters

(50

Nos), Disposable Mouthpieces (250 Nos),


Laptop / Desktop Computer (HP)
-

2 GB RAM, 14” TFT Screen, USB Ports,

DVD R/W, Hard Disc Drive (1x 320 Gbyte), HP Deskjet Printer, UPS.

4.


Treadmill with Exercise
Physiology Kits for
measurement of Cardio


Respiratory
parameters


1.

Technical Specifications of Treadmill.


a.

System should be compatible with exercise physiology kits, of reputed brands, t
esting
cardio
-
pulmonary functions.

b.

Treadmill should be sturdy with wide treadmill belt and supporting arm.

c.

Tread
mill should have the ports for connection with PC or Laptop to perform variety of clinical and research tests.

d.

Treadmill should be digitally controlled.

e.

Have user capacity of 200 kgs or more.

f.


and inclination of more than 20% with increments of 0.5%

g.


and
speed of (minimum)1 Km to 15 Km or more.


2.

Technical specifications of Exercise Physiology Kit for assessment of cardio
-
vascular functions ( to be used with treadmill ).

a.

The system must operate on a 2.4 GHz (minimum), Pentium IV PC platform when operating X
P. When operating on Vista
Ultimate, this determined by the OS.

b.

The systems must have at least 512 k RAM when operating on Windows XP, 1 Gig when operating Vista Ultimate.

c.

The system has minimum of 80 Gigabyte hard drive.

d.

The system must use PC compatible

monitors, printers and external storage devices (hard drives).

e.

The thermal printer must have the capability to print instantaneously a continuous feed.

f.

The system must be mobile.

g.

The system must support a medical grade tread mill.

h.

The system must support
USB compatible peripheral devices.

i.

The system must have ability to produce a final report with or without 12 leads that can be saved in a non proprietary, PDF
format.

j.

The system must have the ability to store or export multiple final reports formats includ
ing in
-
test 12 lead reports.

k.

The system must be able to print 12 lead ECG reports.

l.

The system must be able to score patient test result using Duke Treadmill score.

m.

The system must be able to score patient test results using Framingham Treadmill score.

n.

The
system must be able to score patient test result using Functional Aerobic Impairment (FAI) index.

o.

The system must have the ability to review final report and in
-

test 12 lead reports on screen.


59



p.

The system must have the ability to view 3, 6 or 12 leads on
screen during an exam.

q.

The system must have the ability to edit final report.

r.

The system must be able to import blood pressure from an external device.


3.

Technical specifications for Exercise Physiology Kit for assessment of pulmonary

functions (to be used
with treadmill
).



a.

It should be a portable desktop system for cardiopulmonary exercise testing with a built in colour graphic display, keypad fo
r
data entry and thermal printer for reports with facility to down load performed tests to a computer.

b.

It should

be able to measure VO2, VE, RF and METS, VO2 sub max test.

c.

To be able to measure Resting energy expenditure (RMR, REE).

d.

It should be able to generate various reports based on measurements and data entry for body compositions, weight
management, fitness as
sessment, risk analysis, exercise prescription and training zones and calculate anaerobic threshold.

e.

Flow meter: should be digital bi
-
directional turbine with a ventilation range 5
-
300 L/m, accuracy ±2%.

f.

RMR Flow meter: should be digital bi
-
directional tur
bine ventilation range 0
-
50 L/m, accuracy ±2%.

g.

O2 sensor: with 0
-
22% range, accuracy ±0.02%, calibration automatic on room air.

h.

Power supply: rechargeable battery and mains operated.

i.

Interface: it should have interface for downloading data to latest comput
ers.

j.

Software: software should be supplied with the equipment. The management software should be designed for windows
XP/Vista environment.

k.

Essential accessories: the system should be supplied with all essential accessories required in plug and play conf
iguration,
list of consumables and their life should be clearly mentioned.



5.


Perimeter

Perimeter priestly Smith table model. Used to measure the peripheral field of vision.

The app. Comprises of a calibrated arc, revolving chart holder the object carrie
r which moves over the arc, contains five colours & five aperatures
of different diameter calibrated scale. Adjustable chain rest. All fitted over a sturdy base with receptacle for keeping char
ts. For table top us.
Complete with 100 charts.




Tender Grou
p


Patho



Histo




S. No.

Name of Item

Specification

1.


Trinocular Microscope With
Ten Heads



Ten Headed Microscope With Digital Camera Attachment , Projection System With Appropriate Table For Housing And Seating
Arrangement For 10 People, Computer,
UPS and
relevant software


MICROSCOPE BODY

-

ergonomic design microscope body with built
-
in fly
-
eye lens for uniform illumination through out the field of view incl.
periphery. it should have 3 built
-
in filters(ncb11, nd8, nd32)


MAGNIFICATION
-


20X
-
100
0X for observation


OPTICAL SYSTEM

-

(infinity optical system). eyepiece tube, super wide field, trinocular tube, should be inclined at 25 degree angle with

f.o.v. 22mm. Should be anti
-
fungus type. eyepiece lens 10x (2pcs) with both
sides diopter adjustment (f.o.v. 22mm) should be anti fungus
type.



60



OBJECTIVE
-


Llong working distance plan achro objectives 2x0.10MM.dplan achro, 4X 0.10MM 30.0MM PLAN ACHRO 10X 0.25MM
10.5MM,P LAN ACHRO 20X 0.4MM 1.2MMPLAN ACHRO

40X 1.25MM , 100Xdplan achro.


SPRING
-

LOADED NOSE PIECE
.
-

reversed sextuple revolving nosepiece to accommodate six objectives at a time coarse/fine focusing fine
0.1mm per rotation/coarse 14mmper rotation. coarse motion torque . adjustable refocus
sing stopper should be incorporated.

STAGE
-

rectangular, super hard alumite coated surface , stay in position, stage handle height & tension should be adjustable.

78mm x
54mm cross travel range using low positioned coaxial x and y

motion control on right hand side with capacity to hold two slide
glass at a time. condenser swing out condenser covering magnification from 2x
-
100x



ILLUMINATION
-

12V
-
100W halog
en lamp precentered prefocused. Lamp house should be cordless, voltage (100
-
240V) photo switch
built
-

in auto photo preset switch.

Polarizer plate set to be used in this microscope.

This plate set must be supplied along with microscope.

TEACHING
ATACHMENT

-

should be for ten persons (incl. main observer).

binocular tube of teaching attachment should also be anti
-
fungus type & should give similar viewing as main observer alongwith pointer unit.
pointer of teaching attachment should be moved on an
y direction (360º ROTATABLE)


DIGITAL CAMERA ATTACHMENT
: digital camera capable of handling brightfield, fluorescence, DIC, darkfield images with high density CCD
chip, approx. 5.24 million pixel resolution.


LIVE DISPLAY MODE
, binning modes : 2X2, 4X
4, digital zoom : upto 16X (8 steps) ; interval shooting : 5 sec intervals. Software should come
along with camera for aquiring & capturing of images. should have separate modes for different microscopy techniqu
es i.e brightfield,
fluorescence
, DIC, dark
field images . USB port for attaching camera onto desktop/laptop through single wire. Microscope & camera should be
from same manufacturer for better compatibility.


Data collection and processing unit: branded, 4 GB RAM, DVD writer, 320 GB or higher
HDD, 18.5 TFT monitor, along with color laser printer
and UPS


PROJECTION SYSTEM


Compatible projection system with LCD screen, size
-

40 inches



Computer with UPS, Software & Printer

-

CORE 2 DUO processor running at as minimum 2.93 GHz per core

-

Hard
disk capacity


minimum 320 GB, RAID level 4

-

RAM


4 GB, DDR 3GB

-

Optical mouse, and keyboard

-

Optical drive


16xDVD+/RN Drive

-
USB ports


6 USB, 2 ports


61



-

10/ 100 MBPS LAN, wi
-
fi capability, sound & graphic card, blue tooth capability

-
UPS
-

online U
PS capable of cold boot

-

Peripherals


Multi
-
functional device including color printer, scanner and copier

-
Software as follows:

-

Windows 7/ vista / latest multimedia edition

-

Microsoft Office professional 2010/ latest

-

Adobe photo
-
shop professional latest

A
nti
-
virus software
-

Norton or equivalent, current at the time of delivery

-
Video card Card 512 MB HD 4350

-
19”wide screen flat monitor


true color mode (1280x1024 pixels)

-

5 yr hardware maintenance


Modular Furniture for hosting table and 10 seats

2.


R
ota
ry Microtome
(M
anual
)

-

Coarse feed wheel to support fatigue free sectioning

-

Vertical stroke
-

minimum of 55 mm and maximum of 70 mm




-

Specimen orientation system with calibrated controls XY
-
Axes: 8
0
, and Z
-


Axes : 36
0
0

-

Minimum horizontal specimen advance of 25 mm

-

It should have range of thickness 0,5 μm


100 μm with following steps



0,5 μm from 0,5 μm

-

2 μm



1,0 μm from 2 μm

-

10 μm



2,0 μm from 10 μm

-

60 μm


5,0 μm from

50 μm

-

100 μm

-

Adjustable hand wheel balance system

-

Hand wheel brake to allow the hand wheel to be locked in the upper position

-

Locking system to lock in any position

-

Should facilitate specimen size up to 50 x 50 mm with standard object clamp.

-

The equi
pment supply should include:



Object orientation unit



Standard object clamp




Knife holder base with disposable blade holder for both low profile/high profile blades



Section waste tray


3.


S
lide Warming Plate


-

Temperature range


room temperature to 80
0
C

-

P
rogrammable temperature control in increments of 1
0
C

-

Digital temperature display

-

Black, scratch resistant surface

-

Capable of holding at least 40 slides at one time

-

Inclusive of security mechanisms against overheating

-

220 V
-
240 V/ 50


60 Hz


62



4.


Tissue Float
ation Bath


-

Temperature range


room temperature to 70
0
C

-

Programmable temperature control in increments of 1
0
C

-

Digital temperature display

-

Black color

-

Double layered container

-

With stainless steel lid

-

Inclusive of security mechanisms against overheating

-

220 V
-
240 V/ 50


60 Hz

-

User friendly emptying system


optional

5.


S
lide Filing Cabinet


-

Holding Capacity
-

50,000 slides of size (25x75mm) in vertical position

-

Wheels for movement

-

Double door with chrome plated handle and lock

-

Made of aluminum / stain
less steel

6.


Block Filing Cabinet


-

Holding Capacity
-

20,000 blocks in numerical manner

-

Block type


block embedded in embedding rings/ disposable cassettes

-

Wheels for movement

-

Double door with chrome plated handle and lock

-

Made of aluminum / stainless
steel

7.


X
ylene
, A
lcohol
& F
ormalin
R
ecycler


Can recycle Xylene, Xylene Substitutes, Alcohol & Acetone

90
-
95% Recovery

Electric Hook
-
ups: 220VAC, 7.5 A, 50/60 Hz, 1.70KVA

Capacity


40 litres

Cycle time: 15 to 20 minutes per liter for xylene



20 to 30 minutes per liter for alcohol

Fractional distillation

Microprocessor controlled, fully automated

Automatic waste disposal

No cool
-
down between runs

Built in spill containment

Should Satisfy the latest uniform fire code requirements for
solvent distillation units.

No water hook


up or special ventilation required.

No hot surfaces
-

cool to touch.

Mobile

Electric fill pump.

8.


U
ltrasonic Decalcifier

1.

Integrated temperature controller to set the process time from 1 min. to 100 hrs.

2.

Output sh
ould be of 200 W ultrasonic power and 200 W refrigerated power

3.

Bath volume of less than 15 Ltrs.

4.

Inserts for 4, 9 and 49 sample container with a container volume from 5 to 800ml.

5.

Electronically controlled temperature with digital display range from 12
0
C to

28
0
C

6.

High grade stainless steel powder coated casing with glass top.

7.

Can be used with locally available reagents.

8.

Reduce decalcifying tissue upto 70% with proper maintenance of morphology


63



9.


Slide and Casset
te
Labelling Unit with Printer
Data Integrity & P
rotocol
S
oftware







1.

Standalone compact instrument for printing of Histology slides and cassettes.

2.

It should have non
-
contact printing technology.

3.

It should have throughput of more than 5 cassettes/slides per minute.

4.

Printing should be legible.

5.

It should

have ability to print text, graphics and bar code.

6.

It should have automatic loading and unloading facility.

7.

Loading capacity should be more than 400 slides and 100 cassettes.

8.

It should come along with advance inbuilt software.

9.

It should have facility to v
iew the content before printing.

10.

It should have full database for record keeping and reprinting from history.

11.

Software should be capable to print in incremental or in duplication as required.

12.

Graphical process representation on color touch screen.

13.

It shoul
d be able to store different protocol to recall as and when required.

14.

Power supply 2200V, 50Hz.

10.


Automated Slide Cover
-
Slipping U
nit

-

Processing speed


300
-
600 slides / minute

-

Dispensing volume


40
-
200 microlitres per dispensing

-

Slide loading capacity


20
-
60 slides

-

Reservoir capacity


50
-
150 mL

-

Cover slip size


capable of handling standard Indian cover slips e.g. 22 x 40 mm, 22 x 50 mm

-

220 V
-
240 V/ 50


60 Hz

-

Filtration system


desirable

11.


D
eep Freezer
-

80
0

C

-


Upright, model

-

Temperature range
-

mi
nus 50
0
C to minus 80
0
C

-

Digital display of temperature

-

Double door system or separate doors inside

-

Double walls for insulation

-

CFC free refrigeration

-

Inside chamber capacity


350 to 400 litres

-

Alarm in event of power failure, high or low temperature

-

Prefe
rably frost free

-

Suitable to work on 220 V, single phase, 50 Hz, AC supply

-

5 KVA servo voltage stabilizer

12.


Pressure Cooker Based
Antigen Retrieval System
For CISH/FISH

-

Digital Programmable Pressure System

-

Temperature range


room temperature to 110
0
C

-

Programmable temperature control in increments of 1
0
C

-

Digital temperature display

-

Duration of heating


5 minutes to 55 minutes

-

Insulated container with lid and clamps or equivalent mechanisms

-

Inclusive of security mechanisms against overheating

-

220 V
-
24
0 V/ 50


60 Hz

13.


P
rogrammable
Temperature Regulated
Slide Handling S
ystem
(Kinetic slide S
tainer)




36 slide capacity



With Programmable HOT BAR enable to use temperature from 17
0

C to 95
0

C



Stain and Drain Tilt Rack Technology



36 slide waste receptacle



One

orbital shaker



1 cover for ISH



1 cover for FISH



Capable
of running continuously for atl
east 24 hrs



Temperature uniformity across all slides


64



14.


Water Bath



Temperature range


ambient temperature to 100

o
C



Digital Programmable Temperature system in incremen
ts of 1
0
C




Digital temperature display



Stainless steel make, double walled with stainless steel lid



Inclusive of security mechanisms against overheating



Suitable to work on 220 V, single phase, 50 Hz, AC supply



Size
-

300 x 250 x 175 mm






Tender Gr
oup


Pathology




15.


Digital Camera With Relay
L
ens
For Existing
M
icrosope



igital camera capable of handling brightfield, fluorescence, IC, darkfield images with 2/3” high density CC chip, approx.
RKO4
浩汬楯i p楸e氠reso汵l楯iK



L楶e d楳p污l mode: (5m

楮terface mode


RKV framesLsecK; PT frame per L secK tith olf C b楮i楮iF; b楮n楮imodes W OxOI 4x4I



D楧楴a氠zoo洠: upto 16x (8 steps) ;



Interva氠shoot楮i : 5 sec.


NO hr 楮terva汳K



Software shou汤lcome a汯lg w楴h camera for acqu楲楮g & captur楮i image
s.



Shou汤lhave separate modes for d楦ferent 浩croscopy techn楱ies i.e br楧itf楥汤, f汵lrescence, DIC, darkf楥汤 i浡mes.



䙩牥 w楲i port for attach楮i camera onto desktop/污ltop through s楮ile w楲i w楴h 0.7x re污l 汥ls.


ㄶ1


B楮icu污l M楣roscope



-

兵adrap
u汥lrevo汶楮i nose p楥ce

-

Inc汩ned observat楯i head, 45 degrees 楮i汩ned, rottab汥 through 360 degrees

-

Achromat & aspher楣, parfocal 汥nses w楴h accurate center楮i

-

佢橥jt楶es


4xI NMxI 4Mx Espr楮iFI NMMx Eo楬I spr楮iF

J

bye p楥ce
J

NM x

J


J
ax楡氠l
ow dr楶e mechan楣al stage w楴h smooth 浩cron precis楯i movement

J

䙯cus楮i syste洠


J
ax楡氠coarse and f楮i contro汳 w楴h a focus adjustment range of OR 浭

J

Abbe condenser kA NKOR w楴h aperture 楲楳 d楡ihragm

J

fnter
J
pup楬污ly distance ad橵stment range


RP to TR 浭

J

䙩湥 focus

sensit楶e of sensit楶楴y 汥ls than P 浩cron

J

䙵cgus resistant




65




Tender Group


Patho


Cyto










































17.


Trino
cular Research
M
icroscope
















Microscope stand with built
-
in 6V30W transmitted light Koehler illuminator and UIS2 in
finity corrected optical system,

Quintuple revolving nose piece for attaching 5 objectives at a time, ceramic coated mechanical stage with right drive

handle (movement range 76 mm X
-
direction and 50 mm Y
-
direction; size 188x134mm) field iris diaphragm in
cluding

inbuilt filter 32, 5C
-
2; immersion oil 50cc, Dust cover and hexagonal wrench. Operating voltage, 100
-
240V, AC with

in
-
built stabilizer

Trinocular head with 30 degree inclination and interpupilary distance adjustment range 48
-
75mm

Brightfield c
ondenser N.A. 1.25

30W Halogen bulbs (2pcs)

Plan acromat objective 4X N.A. 0.1, W.D. 22.0

Plan achromat objective 10X,N.A, 0.25, W.D 10.5

Plan achromat objective 40X, N.A, 0.65, W.D 0.6 (spring)

Plan achromat objective 100X N.A, 1.25, W.D 0.13 (spring

oil)

Daylight filter 45 mm diam

Paired widefield eye piece 10X (F.N 20) suitable for user wearing spectacles

Consideration of technical bid subject to physical demonstration of performance and technical specifications at college premi
ses

Penalty clau
se; should not remain non
-
working for more than 7 days, penalty 2% of machine cost per day, after that.



Computer:

2
nd

generation Intel ® Core TM i5
-
2310 Processor (minimum 3 GHz), Genuine Windows 7 Home Professional Premium 64
-
bit 8GB;
DDR3 SDRAM, 500 G
B SATA hard drive (7200RPM), Intel H Graphics 2000/3000; 19” widescreen flat panel monitor

Digital camera attachment:

digital camera capable of handling brightfield, fluorescence, DIC, darkfield images with high density CCD chips
minimum 5.24 million pixe
l resolution, live display mode, binning modes 2x2,4x4; digital zoom 16X, interval shooting 5 sec interval, software should
come alongwith camera for acquiring & capturing of images; should have separate modes for different microscopy techniques ie

bright
field,
fluorescence, DIC and darkfield images, USB port for attaching camera onto desktop/laptop

18.


Waterproof pH tester
(portable
)

1. Microprocessor based LCD display of pH

2. pH range 0.0 to 14.0

3. Accuracy and readability
-

±0.01

4. Auto calibra
tion with temperature adjustment

5. Auto
-
recognization of buffers between pH 4.0
-
9.2 at temperature range 10
-

50
o
C

6. Double junction, replaceable electrodes

7. Battery type. User friendly, battery life of more than 500 hrs

8. imensions approx. 6.5” L
x 1.5” dia


19.


Magnetic Stirrer

Type

Magnetic Stirrer

Speed Range

60 to 1,500 rpm

Temperature Range

N/A

Controller

Electronic Solid State Controller

Dimensions: Plate

190 mm x 190 mm

Dimensions: Overall

205 x 260 x 110 (mm, W x D x H)

Power Consumpti
on

Max. 800 W, 4 A

Voltage

220V, 50Hz, AC supply



66







Tender Group


Patho


Haemato




20.


Fully Automated
Haemoglobin A
nalyzer



Fully Automated Haemoglobin Analyzer



HPLC based system for quantitation of normal and va
riant haemoglobins



Capable of directly analyzing about 25 blood samples per hour



Continuous/ batch wise sample analysis with sample bar code reader



Accurate quantitation with chromatogram print out with patient’s identity



Data Management system software
and data storage of all analyzed samples in serial and chronological order



Auto
-
calibration, temperature compensation with controls for one year



1.5 KVA On
-
line UPS for uninterrupted power supply



Power
-
220+ 10 Volts/50Hz



Warranty
-

Comprehensive five years

warranty with assurance of adequate & regular supply of consumable and spare parts if required



Onsite training of technical staff



Operating manual and directory of haemoglobin variants



Regent kit for analysis of five hundred blood samples


21.


UV
-
VIS Spectr
ophotomter
With Temperature C
ontrol
And Data M
anage
ment
S
ystem




Microprocessor based UV
-
VIS spectrophotometer for photometric analysis (Absorption & Transmittance), Spectral analysis,
Quantitative determination Time scan, DNA/ protein quantitation in stand

alone and PC mode



Peltier based temperature control Temperature range 10
-

50
0
C



High resolution LCD display with dedicated key pad



Photometric system
-

Double beam optics with silicon photodiode



Wavelength range 190
-

1100 nm



Spectral bandwidth ≤ 2.0 nm

over complete range



Resolution
-

0.1 nm



Wavelength accuracy ≤ + 0.2 nm for entire range with automatic wavelength correction



Wavelength reproducibility
±

0.1nm



Photometric range: Absorbance:
-

0.10 to 2.0; Transmittance: 0 to 200%



Photometric accuracy
±

0
.002 abs (0
-

0.5abs) and
±

0.004 abs (0.5
-

1.0 abs)



Photometric repeatability
±

0.001 abs (0
-

0.5abs) and
±

0.002 abs (0.5
-

1.0 abs) and 0.15% T (0
-

100%)



Noise level ≤ 0.001 abs (500
-
700 nm)



Display: four digit LCD display



Baseline flatness ≤ 0.001 abs (
190
-

1100 nm)



Baseline stability < 0.01 abs per hour above 500nm



Scanning speed 1500 or more to 2nm per minute



Light source: 20 W Halogen lamp and deuterium lamp (extra one lamp each in addition to the installed one), auto switchover
according to waveleng
th



Built in validation, calibration and diagnostic program




PC Interphase: RS
-
232




Application software for analysis



Branded computer:Intel Core i5processor, 4GB DDR3 RAM, 500GB HDD, two or more


67





USB ports in front and and four at back, Inte
rnet keyboard, optical mouse, 17 inch



LCD colour monitor, Windows XP/ 7, MS office and antivirus software



Pen drive
-

8GB (2pc)




Branded laser printer (B& W) atleast 20 ppm



Compliance certificate




Online UPS 1KVA


22.


R
efrigerated Microcentrifuge


-

M
icroprocessor controlled microcentrifuge with digital display

-

Speed: RPM
-

0 to 18, 000 and RCF
-

0 to 20,000 g or more

-

Temperature:
-
5
0
C to
+
40
0

C

-

Timer: minute/seconds
-

1 to 99 minutes or seconds

-

Alarm: Lid open/ imbalance/ Temperature warning

-

Vibration
/ sound free operation

-

Rotor for 24 x I.5/ 0.5/ 0.2 ml conical tubes

-

Power: 220V (
+

10%)





Tender Group


Pharmacology




1.


Data Acquisition System

Data Acquisition System with Isolated Tissue Study Equipment which is capable of recording of biopotentials
, respiratory parameters
and cardio Vascular Physiological Parameters.




Software with automatic beat classification , E.C.G. averaging , automatic calculation of R.R. interval, QRS interval, P ampl
itude, QT
interval and R interval.



Pressure relatd paramete
rs such as mean pressure, maximum pressure and diastolic pressure, systolic
-
diastolic pressure, ejection
time and pulse pressure.



Respiration parameter such as peak inspiratory flow, peak expiratory flow, tidal volume, minute ventilation, flow volume capa
c
ity and
curve.



Animal bioamplifier for biopotentials.



With transducers and accessories: Physiological pressure transducer
-

for blood pressure. Forced transducer (5 mg to 25 g) for force
and displacement.



Needle electrodes
-

29 gauge, 2 mm pin for biopotenti
al ECG.



Two chamber organ bath for isolated tissue (25
-
50 ml chamber size).



68






Tender Group


Microbiology


1.


Trinocular Advance
Rese
arch
Microscope For
Bright Field, Phase
Contrast , Dark
Field,
Fluorescence &
Digital Image
Analysis

System


MICROSCOPE BODY



ERGONOMIC DESIGN MICROSCOPE BODY WITH BUILT
-
IN

FLY
-
EYE LENS OR EQUIVALENT TECHNIQUE & 3 TRANSMITTED LIGHT FILTERS


MAGNIFICATI
ON




40X
-
1000X FOR OBSERVATION


OPTICAL SYSTEM



(INFINITY OPTICAL SYSTEM).


EYEPIECE TUBE



SIEDENTOPF DESIGN SUPER WIDE FIELD

TRINOCULAR TUBE, SHOULD BE INCLINED AT 25
-
30 DEGREE ANGLE OR BETTER
WITH
F.O.V. 22MM

OR BETTER.


EYEPIECE LENS

10X (
2PCS) WITH BOTH SIDES DIOPTER ADJUSTMENT
(F.O.V. 22 MM OR BETTER)

SHOULD BE ANTI
FUNGUS TYPE.


OBJECTIVE

HIGH NA. & LONG WORKING DISTANCE OBJECTIVES SUITABLE FOR BRIGHTFIELD, PHASE
CONTRAST, FLUORESCENCE & DIC MICROSCOPY.



OBJECTIVE



N.
A

W.D


PLAN ACHRO 4X

0.10 30.0MM

PLAN ACHRO 10X

0.25 10.5MM, PH1

2.


Refrigerated Centrifuge

S. No.

Particulars

Minimum Specifications

1.

Compliance

Able for CFR
-

21 Compliance (USFDA); CE

2.

Configuration

Motorized lid
-
locking and automatic
rotor recognition

Imbalance cut
-
out; 10 different acceleration and brake rates

3.

Temperature considerations

Temp range:
-
9 to 40


C

Temp function for fast pre
-
cooling; Standby cooling and Economic shutoff on long time unuse.

Built
-
in condensation drain

to eliminate water accumulation and prevent corrosion

Rotors can be spun at maximum speed while still maintain 0
-
4°C

4.

Speed

Spinning upto 25,000g or 16,400 rpm

Speed can be set from 200 rpm to maximum speed in increments of 10 rpm

5.

Interface/

Contro
l Panel

Simple programming of time, temp, radius and speed

Short spin button and Adjustable speed

‘at set rpm function’ timer shlould start when the speed is reached

30
-
35 user programme capacity

Values can be changed during Centrifugation

6.

Modular acc
essory and Function

Must cover comprehensive applications for PCR tube strips and 1.5/2 ml test tubes as well as
high
-
volume centrifugation of Falcon® tubes, flasks and filter plate systems .

Handling Capacity of upto 400 ml

7.

Rotors/

Adapters

To allow m
ost commercially available tubes & plates; Flexible modular design so that different
tube lengths fit into one adapter.

Made of autoclavable materials and suitable on benchtop models.

Equipped with all types of Fixed Angle Rotors and swing
-
bucket rotors fo
r 15 ml tubes and PCR
plates & culture plates

8.

Tools

All tools required to open and reassemble the rotors.

9.

Accessories

Instrument must be provided along with a suitable VOLTAGE STABILIZER



69



PLAN FLUOUR 20X

0.5

2.10MM,PH1


PLAN FLUOR 40X

0.75


0.72MM,


PLAN APO 60X OIL

1.40


0.13MM,


PLAN APO
100X OIL

1.40


0.13MM,




NOSE PIECE.




REVERSED SEXTUPLE REVOLVING NOSEPIECE TO






ACCOMMODATE SIX OBJECTIVES AT A TIME


COARSE/FINE FOCUSING

FINE 0.1MM PER ROTATION/COARSE 14MM

PER ROTATION. COARSE MOTION TORQ
UE ADJUSTABLE.

REFOCUSSING STOPPER SHOULD BE INCORPORATED.


STAGE

X AND Y RECTANGULAR MECHANICAL STAGE MOTION CONTROL ON

RIGHTHAND SIDE WITH CAPACITY TO HOLD TWO SLIDE GLASS AT A TIME.


C
ONDENSER




UNIVERSAL CONDENSER SUITABLE FOR ALL MICROSCOPY

TECHNIQUES











ILLUMINATION

12V
-
100W HALOGEN LAMP PRECENTERED AND

PREFOCUSED. LAMPHOUSE SHOULD BE CORDLESS WITH WORLD WIDE VOLTAGE (100
-
240V)


PHOTO SWITCH


BUILT
-

IN AUTO PHOTO PRESET SWITCH.


FLUORESCENE ATTACHMENT


120W OR MORE MERCURY /METAL HALIDE FIBER LIGHT

ILLUMINATOR WITH LAMP LIFETIME OF 1500
-
2000 HOURS FOR FLUORESCENCE AND LONG
TERM OBSERVATION

OF THE SPECIMENS.

SHOULD HOLD SIX FLUORESCENCE FILTER BLOCKS IN

ROTATING TURRET. BUILT
-
IN ND4/ND8 & ND16 FILTER.




FILTER BLOCK FOR BLUE WITH EXCITATION FILTER EX450
-
490, DICHROIC MIRROR
DM505 AND BARRIER FILTER BA520 FOR FITC/ACRIDINE ORANGE/AURAMINE
.




FILTER BLOCK GREEN WITH EXCITATION FILTER EX 510
-
560, DICHROIC MIRROR
DM575 AND BARRIER FILTER BA590 FOR TRITC/RHODAMINE/PROPIDIUM IODIDE.




FILTER BLOCK UV WITH EXCITATION FILTER EX 330
-
380, DICHROIC MIRROR DM400
AND BARRIER FILTER BA420 FOR DA
PI/ HOECHST




DIGITAL CAMERA



DIGITAL COLOR COOLED CAMERA CAPABLE OF HANDLING

BRIGHTFIEL , FLUORESCENCE, IC, ARKFIEL IMAGES WITH 2/3” HIGH ENSITY CC
CHIP, APPROX. 5 MILLION PIXEL RESOLUTION. PELTIER COOLING

20ºC BELOW AMBIENT.
FIRE WIRE PORT F
OR FAST DATA TRANSFER ONTO DESKTOP/LAPTOP THROUGH SINGLE
WIRE. CAMERA CONTROL UNIT SHOULD CAPABLE TO CONTROL TWO CAMERAS
SIMULTANEOUSLY



70




Software should be with following features:




Acquisition and device control through four
-
dimensional acquisition.



Image Acquisition,



Time Lapse Imaging,



Z
-
Stack, Multi
-
channel Fluorescence, Annotation,



2D / 3D View, ND Viewer,



Filter,



Morphology, Large Image,



Macro,



Segmentation,



Auto
-
measurement,



Report Generator facility,



Data Base, Vector layer & Multi
-
Dimens
ional File Format (ND format)



Microscope, camera & software should be from same manufacturer for better compatibility.


Data Collection

unit:




Branded
, 2 GB RAM, DVD

Writer, 320 GB or higher H , 18.5” TFT Screen alongwith UPS


2.


Biosafety Cabinet
Cla
ss II B2



1.

Should have a work area of 1200x600x500 mm (approx.) with shutter opening of 489mm

2.

(4 ft.). Overall size 1300 x 825 x 2450mm (approx.).

3.

Should have 100% exhaust vertical down air flow with an average air flow rate of 90±20 fpm

4.

Cleanliness l
evel should be less than 3.5 particles/litre of 0.5 um and larger (ISO 14644
-
1)

5.

Noise level should be less than 65db

6.

Vibration should be less than 2.5um

7.

Main body, Side walls & Table top and working zone should be made of 16G stainless steel (304 grade).
Table top should be in 2 parts:

a) Front perforated portion


4” size;

b) Non perforated working zone should be table sunken type for spillage management.

8.

The HEPA filter should have rated efficiency of 100% at 0.3 microns to provide product protection of

Class100 or exceeding Class 100
requirements of Federal Standards 209E or equivalent ISO within the work area.

9.

The equipment should be mounted on a stand with leveling feet. The exhaust plenum should be under negative pressure,

hard ducted to
the

outside.

10.

Should have an air pressurization system statically and dynamically balanced with special vibration reducing system.

11.

Front door should be of Polycarbonate / Toughened Glass (6mm) with vertical sliding adjustment (1 piece with counter weight a
rran
gement
fingertip control).

12.

Light Intensity at work surface: 800 lux or more over the entire work surface.

13.

UV germicidal lamp intensity: >40 microwatt/sq.cm over the entire work surface.

14.

Should have Universal service fittings for Gas & Air

15.

Prefilter:
-

Filtr
ation efficiency of 98% for all types of particle sizes 8 micron and larger

16.

Should have pressure monitors, DOP port, current leakage circuit breaker and air tight duct exhaust extension.

17.

Should have audible alarm which warns the operator if the window is
raised above the recommended height of 203mm (8”).

18.

Should have safety suction points near the upper portion of the front shutter to transfer short circuit dirty air into exhaus
t/return duct.

19.

Should have adjustable zero leak proof damper at supply air intak
e and exhaust ducting.

20.

Should have provision for a system which gives alarm to supply air in case the negative pressure goes beyond certain limit to

stop
contamination egress to laboratory.

21.

Power input to be 220
-
240VAC, 50Hz fitted with Indian plug

22.

Equipme
nt quoted should comply with Indian Standards Institutions Guidelines or any other National or International Guidelines.

23.

The unit shall be capable of being stored continuously in ambient temperature of 0
-
50deg C and relative humidity of 15
-
90%.

24.

The unit s
hall be capable of operating continuously in ambient temperature of 10
-
40deg C and relative humidity of 15
-
90%



71



25.

Voltage corrector/stabilizer of appropriate ratings meeting ISI Specifications.( Input 160
-
260 V and output 220
-
240 V and 50 Hz)

26.

Should be FDA
, CE,UL or BIS approved product


27.

Should have individual switches and indicator lamps for blower motor, florescent lamp and UV lamp.

28.

Spare accessories:
HEPA Filter (one)
-
dimensions same as above, Prefilters (two).

29.


Resettable over current breaker shall be f
itted for protection




Manufacturer/Supplier should have ISO certification for quality standards.

Should be compliant with IEC 61010
-
1 :( or any international equivalent eg EN/UL 61010) covering safety requirements for electrical equipment for
measurement

control and laboratory use


The Cabinet should be tested and comply with the requirements:


1.Downflow Velocity Profile

2.Inflow Velocity Test

3.Airflow Smoke Pattern Test

4.HEPA Filter Leakage Test

5.Electrical Leakage Ground Circuit Resistance and polar
ity Test

6.Lighting Intensity Test

7.Vibration Test.

8.Noise Level Test

9.UV Lamp Intensity Test

10. The differential pressure gauge should be calibrated.


Note
: All the above Tests will have to be conducted and certified by an accredited agency.


Please p
rovide the name and address of the firm agency that will test and certify the LAF. Also necessary proof of accreditation with

the appropriate
national or international laboratory should be provided.


3.


Inspissator

1.

A shallow stainless steel tray should be
rested inside a tank containing water.

2.

The whole undersurface of the tray must be in contact with water at a constant temperature which ensures that the temperature

of the
McCartney bottles with media is also constant.

3.

The surface of the tray is a series o
f sloping steps (at 9 degree angle above the horizontal) and will hold 162 universal containers.

4.

A blanket should be placed over the containers to exclude draughts and a quilted cover provides thermal insulation.

5.

Both blanket and quilt are made from insect
-
resistant materials.

6.

The temperature of the water under the tray is must be controlled by a digital immersion thermostat.

7.

Accuracy and reproducibility of set temperature are ensured with the digital display

1.

of actual and, at the touch of a button, set tem
perature.

8.

The control unit should be mounted on a bridge plate over one end of the bath, from which heater; stirrer and temperature sen
sors project
down into the bath.

9.

All moving parts should be incorporated in the control unit which removable for servicin
g.

10.

The tray and tank are made of stainless steel and are fitted in an outer case of laminated wood.

11.

A constant level device is fitted maintain the water level despite evaporation losses.

12.

Std temperature must be 85ºc;

13.

Operating temp. Range should be: ambien
t to 90ºC.;

14.

It should have LED temperature display and Display resolution: 0.1c;

15.

Voltage regulators of appropriate rating should be included for each item ton cope with 160
-
260 V.8

16.

Uniformity: tray surface + or
-

0.7c;

17.

Heater power should be (approx.) 1.4K
w, 230V;

18.

Tank capacity should be (approx.) 45 lit.

19.

Working area should be approx 820/594 mm (length/width)

20.

Overall dimensions should be approx 1040/600/380mm (l/w/h)


72



21.

Over temperature protection should be fixed cut
-
out;

22.

Electrical power: 220
-
240V 50/60 Hz,
1.5kW (approx.)

23.

Approx.weight: 25
-
35 kgs.

24.

Voltage regulators of appropriate rating should be included for each item to cope with 160
-
260 V.

25.

The instrument should be rust free.



4.


Ultra Sonicator



Sealed tender bids are invited for supply of one number U
ltra Sonicator suitable for shearing of DNA, lysis of bacteria and other cells with the following
minimum specifications:




Ultrasonic wave frequency ~20kHz



Ultrasonic wave output power should be switchable in steps in the range of 130 W to 200 W (± 10%)



Sy
stem should be capable of multiple samples in closed tubes to be processed simultaneously using either 0.5ml, 1.5ml, 10ml, 15
ml or 50ml
tubes with no chance for cross
-
contamination between samples.



The system should accept a minimum of 12 x 0.5 ml or 6 x 1
.5 ml or 6 x 15 ml.



Any design that allows minimal loss of sonication energy between the instrument and the sample.



The system should be compatible with sample volumes of 100 μl (in 0.5 ml tube) to 20 ml (in 50 ml tube).



Ability to maintain sample temperature at about 0
-
4°C.



An integrated box/cabinet to reduce sonication noise.



Power supply
-

220
-
230V, 50/60Hz



Analog/Di
gital timer should permit precise control of cycle ON or OFF settings for highly reproducible performance.



Comprehensive warranty should be provided for 2 years with an optional 3rd year warranty.



A requisite system for constant voltage output such as a su
itable branded UPS or other power regulator system of appropriate rating should
be quoted.



Attachment Accessories Adaptors should be quoted as optional for 0.5, 1.5, 15 and 50ml tubes



Any specialized accessories or consumables should be quoted as an option
.



List of Indian users for similar equipment must be enclosed. A letter from at least three users from National Laboratories/ I
nstitutions /reputed
Biotech Industries in India certifying the performance of same/similar equipment and service by the supplier

for 2 years or more.



A letter from Original Equipment Manufacturer to the effect that they will support the equipment at least for a period of 5 y
ears from the date of
installation.


5.


Micro
-
Plate ELISA
Reader



96 well Micro
-
plate absorbance reader with 8
-

position filter wheel, with on board software

for data analysis.



Should have Quartz tungsten halogen lamp as a light source with at least 5000 hr life



Should have Absorbance, Dual wavelength, 2 point mode, kinetic mode multi wavelength


mode & Cut
-
of mode programming parameter



Should have fast & slow reading mode. Fast Reading (5 sec) at single wave length &


automatic calibration before each reading. Warm up time for the instrument should not be

more than 1 minute



Should have built in variabl
e speed plate
-

shaking capability



Wavelength range 400
-
750nm, Absorbance range 0
-

3.5 Abs with linearity at least 0
-
2 Abs

with resolution 0.001 Abs, accuracy at least +/_ 2%



Should be supplied with software for statistical analysis of data



Should be a
ble to store at least 64 user defined on board program

6.


Micro Plate ELISA
Washer



Semi


automatic Micr
o plate ELISA washer with co
-
axial wash heads for excellence washing & can be switched between 8 & 12 way wash
heads.



Should be supplied
with at least 4

standard program cards (1
-
4 washing cycles) & one programmable card for user defined program.



Dispensing precision should be
at least 5%



Should be
supplied with one wash bottle & one waste bottle of 2 lit capacity each



Residual aspiration volume < 5 μl



73



7.


Microcentrifuge



Should be table top model



Should have LED display speed and time with auto time setting device.



Should have memory programs for presenting parameters



Should be microprocessor controlled



Should have auto
-
accelerating decelerating and tran
sient centrifugal function.


-
Auto cover
-
lid lock power cut off when open the cover.


-
Auto
-
brake system for presenting.



Stainless steel rotor inner should be sterilizable



Should have autobuzzer system when fi
nish operation



Should have auto
-
balance and imbalance device



Should have auto
-
cooling circulation.



Speed upto 15,000RPM



Max. RCF (x g) 21,000



Max. Capacity (ml)1.5/2.0 x 18 with adapter for 0.2


0.5ml



Timer 0
-
99 min.


8.


Ice Matic Machine

1.

Production capa
city 90
-
120kg/day

2.

Bin capacity Built
-
in storage 25
-

30 Kg

3.

Condensation/cooling
-

Air Cooled

4.

Refrigerant
-

CFC free.

5.

Freezing cylinder
-

Stainless Steel

6.

Bin Exterior
-

Stainless Steel

7.

Bin Full


Auto Stop/ Start

8.

Control
-

Microprocessor control with LED ind
icator

9.

Operating Temperature


10 to 37ºC.

10.

Drainage
-

Pipes Provided

11.

Compressor hermetically sealed.

12.

Noise Level


Very Low noise level

13.

Bin


highly hygienic with PUF insulation.

14.

Legs (for Level Adjustment)
-

screw type legs.


9.


Automated Glass
Washing Sys
tem



All
-
dimensional effective spray cleaning the objects inside and outside to ensure a best cleaning and disinfection result.



Should be able to wash glassware like Petri dishes, flasks, beakers, test tubes, universal containers, Bijou bottles and McCa
rtn
ey bottles.



Multitronic control system featuring seven standard programmes(pre
-
wash,super quick, fast, rinsing, economy, standard, powerful washing)
and one custom programme slot




With auto
-
diagnostic checking that constantly monitors and displays current

cycle status and alarms




Buzzer signals end of program and program failure check




Easy to use, the LCD touch control system can simplify the end user job when operating the machine.




Direct basket coupled system to water feed for efficient water usage, an
d maximum basket flexibility for load to load




Automatic contamination discharging: double pump structure, double stainless steel filter



74





Automatic brighter agent dispenser and self
-
alarm system.



Double wall construction and thorough insulation reduce ele
ctricity consumption and heat loss.




Standard steam condenser eliminates vapours




Heavy washing pump ensures high flow rate combined with effective spray pressure.




Inner cabinet, washing arms and tank filters made of high quality AISI 316L stainless steel
.




Self cleaning tank with rounded edges.




Detergent auto
-
supply machine is available




Large capacity of water softener for a continuous supply of softened water
should be
available.




Water pressure to be adjustable; the column of water jet should also be
adjustable



Housing for egress water must be splash proof and its flow regulated



Automatic drying of washed glass ware must be available



Softened water to be pumped to geyser and inlet water into the system only after the treatment of raw water to soften
it



All material should be compatible with any detergent and must be corrosion resistant

Inlet water pressure: 0.04


1.00 Mpa

Water pressure in chamber: 0.3


0.4 Mpa

Compound vacuum filter: minimum size ≥10μm

Maximum Power: ≤ 1760W; Noise: ≤ 50dB

Inner ch
amber size: 160L; Exterior size: 590×595×850 mm

Net weight: ≤43kg

10.


Vertical Autoclave

1.
Should be a vertical autoclave having inner dimensions of 350 x 550mm.

2.

Should be double walled with outer stainless steel 304 & inner stainless steel 18 SWG sheet
.

3.

Lid should be made of S.S.plate & tightened by radial locking system with foot lifting arrangement to open the lid.

4.

Should be fitted with joint less silicon rubber gasket.

5.

Should be equipped with pressure gauge, steam release valves and safety v
alve.

6.

Should be fitted with water level arrangement to indicate water position inside the boiler.

7.

Should be fitted with automatic low water level cut of devise.

8.

Should be fitted with a digital timer and a digital temperature indicator.

9.

Should h
ave an automated pressure switch which can be set from 5 psi to 20 psi ± 2 psi & should

have drain.

10.
Should have SS perforated basket.

11.
Should have a cord & plug to work on 220 volts and 50 cycle AC supply.

12.
S
hould be fitted with 3 KW ISI marked immersion type heating element.

13.
Autoclave to be supplied with 4 no’s silicon rubber joint less gasket and 6 no’s 3 KW ISI marked immersion type heating elem
ent.


Manufacturer/Supplier should have ISO certification
for quality standards.



75



11.


Vertical Autoclave
(Small)

1.
Should be a vertical autoclave having inner dimensions of 250 x 450mm.

2. Should be double walled with outer stainless steel 18 SWG & inner stainless steel 18 SWG sheet also.

3. Lid should be made of
S.S.plate.

4. Should be fitted with joint less silicon rubber gasket.

5. Should be equipped with pressure gauge, steam release valves and safety valve.

6. Should be fitted with water level arrangement to indicate water position inside the boiler.

7. Should

be fitted with automatic low water level cut of devise.

8. Should be fitted with a digital timer and a digital temperature indicator.

9. Should have an automated pressure switch which can be set from 5 psi to 20 psi ± 2 psi &

should have drain.

10. Should have SS perforated basket.

11. Should have a cord & plug to work on 220 volts and 50 cycle AC supply.

12. Should be fitted with 1 KW ISI marked immersion type heating element.

13. Autoclave to be supplied with 2 no’s
silicon rubber joint less gasket and 2 no’s 1 KW ISI marked immersion type heating element.

Manufacturer/Supplier should have ISO certification for quality standards.


12.


PCR Work Station

1.
Microprocessor controlled.

2.

Class 100 (ISO 5) vertical

laminar flow

3.


360
-
degree visibility.

4.

Integral polypropylene base for easy cleaning.

5.

Built
-
in fluorescent light.

6.

HEPA filter monitor to automatically indicate when filter change is required.

7.

Voltage 220 V.

8.

At least 2 three pin sockets wit
h 220V power supply; 60Hz.

9.

Dimensions 24
״

± 6
״

depth, 30
-
36
״

width (Front).

10.

Shortwave UV light.

11.

Custom sturdy cart for unit to be made portable.

12.

Spare set of HEPA filters.

13.


Vortex Mixer

-

Cup type to take up tubes and small vials for thoro
ugh mixing.

-

Variabl
e speed range from 300
-
2500 RP

-

Warranty 3
-
5 Yrs.

-

Service net work

-

Users list

14.


Monocular
Microscope

ITEM

SPECIFICATION

Body

Aluminum die
-
cast monocular body

Inclined Observation Head

45 degree monocular, rotatable through 360
degrees

Eyepiece (Widefield) for
observation

WF 10x (F.N.18) paired compensating eyepiece with color compensated images of utmost clarity.
Compatible with an optionally available eyepiece micrometer.

Nosepiece

Quadruple revolving nosepiece

Objectives

Achromat objectives 4X,10X 40X(Spring) & 100X (Oil immersion)

Mechanical stage

Right
hand co
-
axial double plate mechanical stage, movement 60mm X 25mm , size 120mm X 120mm

Focusing system

Separate fine and coarse focusing adjustment knobs with tension co
ntrol mechanism

Condenser

Condenser N.A. 1.25 with iris diaphragm focusable by spirl movement

Illumination base

Built
-
in illumination base with pre
-
centered 6V 15W halogen light source. Bulb with efficient collector
lens system for optimum brightness.
A rotable knob for variable light control.



76



15.


Shaker Incubator
with adaptor





Should have front loading with glass window to see
-
through for observation of samples during operation without opening the door with built
-
in
working lamp



Should have volume adj
ustable holders holding various shapes of containers



Should have slow stop and start of shaking motion which provides smooth operation and prevents shock



Should have automatic cut
-
off of shaking motion on opening of door



Platform should be suitable for 50m
l, 100ml, 250ml, 500, 1liter and 2 liters conical flasks or beakers and must have provision for test tube
stand.



Temperature range Ambient + 5°C to 70°C



Temperature display resolution 0.1°C



Temperature precision ± 0.2°C



Temperature fluctuation ± 0.2°C



Temp
erature variation <0.2°C



Speed range ± 1rpm to 400rpm



Power 220
-
240 V; 50/60 Hz



Comprehensive warranty should be provided for 2 years with an optional 3rd year warranty.



Attachments, Accessories and Adaptors should be quoted as optional



List of Indian use
rs for similar equipment must be enclosed. A letter from at least three users from National Laboratories/ Institutions /reput
ed
Biotech Industries in India certifying the performance of same/similar equipment and service by the supplier for 2 years or m
ore
.



A letter from Original Equipment Manufacturer to the effect that they will support the equipment at least for a period of 3 y
ears from the date of
installation
.

16.


Refrigerated
Shaking Water
Bath

Inner size of the water chamber:
-

400 X 200 X 160 mm (dept
h)


Capacity:





20
-
25 lts


Temperature range:



0ºC to 100
o
C


Accuracy:




± 0.1
-

0.5
o
C


Temperature control method:


Microprocessor PID controlled


Shaking rate (rpm):



10
-
200


Sensor:




PT. 100


Mount:




Table top.


Inner body:





S.S. (304)


Outer body:




M.S. with powder coating.


Flange:




S.S. (304)


77




Insulation:




PUF insulation


Display and controller:


Digital


Input voltage:




220V, 50 Hz.


17.


Deep Freezer



20
0

C

1.

Vertical double walled body made of high grade s
teel with rounded corners

2.

Two doors (upper and lower) and each door being double

3.

Compartmentalized chambers (at least 5 with separate plastic/glass doors).

4.

Capacity: 340
-
400 Liters

5.

Temperature range with display (
-
15oC to
-
25oC)

6.

Accuracy = 1
o
C

7.

Fast freeze
r switch

8.

Safety fuse, shock protection and locking facility

9.

Suitable voltage stabilizer

10.

Accessories: fuses, racks, storage boxes with dividers etc.

11.

Power back up for 4 Hrs. : On line UPS compatible with the system



Tender Group


Community Medicine


1.


S
kin F
old
Thickness
C
alipers

Should accurately measure subcutaneous tissue. Measuring range: 0 mm to 50 mm minimum. Dial Graduation of at least 0.2 mm. A
ccuracy of at least
99%. Supplied in a protective cover.


2.




Portable
S
pirometer

Portable spiromete
r with display screen, built in printer, patient data memeory, and PC compatibility, which can measure all parameters of lung

function
such as FVC, SVC and MVV.




Tender Group


Skill Laboratory


1.


Endotrainer

Endotrainer for practicing minimally invasi
ve surgery skills. It should include

1.

Endotrainer: Beetle type with built in adjustable endocamera and light source (CFL). It should have ports for introducing han
d instruments. The
camera should be colour type and capable of direct attachment to TV.

2.

21 inc
h TV monitor, LCD type with stand.

3.

Hand instruments for laparoscopic surgery (Reusable)

a.

Maryland dissector


One

b.

Grasper (non
-
tooth)


One

c.

Needle holder


One


78



d.

Scissors


One

4.

Stand for LCD TV


One

5.

Trolley for endotrainer


One

The design/ photograph of the

stand and trolley should be provided with the quotation.


Tender Group


MIU


1.


Large Format A
-
3
Inkjet Printer



Inkjet Printer



Capable of printing on A
-
3, A
-
4 and wide (16 inches or more) continuous roll paper



Speed : 10
-
14 sqm/hour



Resolution : B/W and

Colour


2400 x 1400 dpi or more



Borderless printing in variable size



Inbuilt cutter



Media


Plain / Photo / Continuous Roll Paper


Max. Media size


16 inches wide / more, in any length


Max. media thickness upto 1.5 mm



Autoload


A
-
3 / A
-
4 sheets and se
parately for paper rolls



Expansion slots



Eight to ten colour ink cartridges



Software


Windows XP based



Power 220
+

10 V



Voltage Stabilizer 1 KVA (Branded)

2.


P
lotter Printer



Plotter Printer



Large format color inkjet printer



Operating software Windows XP
/ 7



Capable of borderless printing on 44 inch wide roll papers upto A0 length



Resolution 2800 x 1400 dpi or more



Six to Eight colour printing with individual high capacity ink cartridge




Speed : High speed poster printing



Memory : 64
-
128 MB or more



Interfa
ce


High speed USB 2.0 port





Ethernet port



Print Media


Plain / Photo quality sheets/rolls






Maximum width 44 inches






Maximum thickness 1 mm



Inbuilt cutter



Color ink cartridges 8
-
10 high capacity cartridges



Voltage stabilizer


2.0 KVA (BRA
NDED)



Power


220
+

10 volts


Tender Group


Central Animal House


1.


H
eated Circulating
Water


Bath


S. No.

Particulars

Minimum Specifications

1.

Compliance

Able to be CFR
-

21 Compliance (USFDA)

2.

Reservoir/Capacity

Bath Depth

Made of Sta
inless Steel with Bath Opening of approx 200 x 150 mm

Capacity atleast of 6
-
8 Litres


79



Bath Depth

Atleast 180
-
200 mm

3.

Operating Temperature

Heating and Cooling thermostats for temp range
-

30 to 120° C

Temperature to displayed both in °C or °F

Operating Range in °
C:
-

25 to 120
° C Centigrade

4.

Control & Energy Regulation



Adjustable over
-
temperature and low
-
liquid
-
level safety shutoffs.



Automatic compressor control for automatic cooling over the entire operating range



Energy
-
saving modified PID temperature contro
ller.



User
-
calibrated electronics allow display temperature to be verified against a calibrated
source



Closed loop system flow rates up to 20L/min with 0.4bar outflow pressure

5.

Compressor and Thermostats



Automatic Compressor Controls supplying strong c
ooling only when needed



Immersion and Heating thermostats with screw clamps



Removal of Front Cover without tools for cool air inlet.

6.

Control Accuracy

Temp stability

°C: ±0.02

°C: 0.05

7.

Cooling Capacity

Cooling Capacity @ 20°C: 390W

8.

Refrigerant
s

CFC
-
free R
-
134a refrigerant

9.

Accessories

Instrument must be provided along with a portable/suitable VOLTAGE STABILIZER


2.


TISSUE
HOMOGENIZER


S. No.

Particulars

Minimum Specifications

1.

Compliance

Ability for CFR
-

21 Compliance (USFDA)

2.

Config
uration



High
-
performance dispersing instrument for volumes ranging from 0.5


3 ml.



Infinite speed variable controls



Reproducible operations due to constant speed even with viscosity changes




Digitalized Disperser



Extension Arm



Rotors arm made of stainles
s steel

3.

Motor Speed Range


Motor Speed Display


Design Voltage

3400
-
24000 min
-
1


3 digit LED display; displayed value x 1000 units


230 V

4.

Speed Variation on load change

<1 %

5.

Permissible Ambient Temp


Perm. Humidity

5
-
40 Degree Centigrade



70
-
80%

6.

Noise levels without dispersion
tools


Frequency

73
-
75 dbA



50
-
60 Hz

7.

Protection Class

Contamination Level

II

II



80



3.


O
rbital Shaker With
Platform

S. No.

Particulars

Minimum Specifications

1.

Configuration



Low profile laboratory shaker with a

large mounting surface



Orbital type Shaking application



Load capacity of up to 12
-
15 kg.



With Timer and LED Speed Display application

2.

Speed

Infinitely variable speed control of 0
-

300 rpm

3.

Timer Setting

Timer setting for 1 to 50 min / continuou
s mode also available

4.

Display and Design

Digital display

Orbital diameter atleast 30 mm

Ideal for vessels with a volume of more than 250 ml, e.g. round flasks, Erlenmeyer flasks,
culture flasks and culture bottles

Guaranteed continuous operation (endle
ss) even under extreme loads

5.

CO2 Regulation


6.

Compulsory Accessories

It should be supplied with required attachments

Universal separating funnel attachment / fixing clips etc




4.


M
agnetic Stirrer Cum
Hot Plate


S. No.

Particulars

Minimum Specific
ations

1.

Configuration



High
-
performance multi
-
position magnetic stirrer with 15 stirring positions and integrated
temperature control plate



Option for simultaneously operating stirrers

2.

Stirring Specs

Approx 15 stirring positions

90 mm stirring distan
ce



Stirring Quantity upto 6 lit

Stirring Bar Length 25
-
30 mm

3.

Speed Range

0
-
1100 rpm

Upto 5% speed deviations on individual stirring

Motor rating input atleast 20 watt and rating output atleast 5 watt

4.

Heating/Temp Range

Room Temp to 110 degree
C

1
-
10 Heat Control

Permissible ambient temp 5
-
40 degree C

5.

Plate Specs

Silicone Plates with approx 250 x60 x 450 mm size

6.

Compulsory Accessories

It should be supplied with all required attachments for ready functioning

with suitable voltage
stabili
zer.


5.


Inverted Microscope



Focussing:

Infinity optical corrected; Vertical objective movement

Via nosepiece up/down movement; Stroke (manual): up 8mm, down 3mm

Coarse stroke: 5.0mm/rotation; Fine stroke: 0.1mm/rotation; Minimum fine reading: 1 µm



Illum
ination
: Diascopic Illumination Pillar 100W



Eyepiece Tube



Binocular tube with side photo ports



Port
: Manual port switching; provision for a camera port to be made available.



Eyepiece
: Lens


CFI 10x, 12.5x, 20x, 40x; Diopter adjustment facility



Objectiv
es
: CF160 objectives



Nosepiece
: Sextuple Nosepiece



Stage
: resistance to vibrations; wide stage surface for accommodating cell plates; improved X
-
Y cross
-
travel & with upper limit stopper.



Condenser
: Suitable condenser for Cell Culture examinations



Model of

Imported quality


81



6.


Auto Scrubber Drier



Model Design: Walk
-
Behind Model; Electrically operated model which is cable powered; supply 230V



Tank Capacity:

Solution/Clean Tank capacity atleast > 55 Lit

Recovery/Dirty Tank capacity atleast > 60 Lit



Working Su
rface/Productivity Range (m
2

/hr): in range of 1700
-
2000



Scrubbing Width: approximately 450
-
500 mm



Squeeze Width: approximately 750
-
800 mm



Power Brush Motor (V / W):

230 V / in range of 600
-
800 W



Power Suction Motor (V /W):

230 V / in range of 350
-
650 W



Specific Job Capabilities:

Ensure perfect cleaning on all hard surfaces and effective scrubbing of floors

Rotating brush arrangement for effective scrubbing

Optimal distribution of weight, easy to handle and manoeuvre

Tanks made of Non
-
Rusting and Non
-
Cor
rosive surface

Machine with Big wheel for vibration free operation

Optimum cleaning with High Brush pressure



Model of International grade Quality

with voltage stabilizer and atleast 10 mts. electrical extension cord.


7.


Stainless Steel
Trolleys



General Spe
cifications for Trolleys (other than Waste Trolleys):



Made up of authentic heavy duty AISI 304 quality grade Stainless Steel; Complete Body in ‘Matt Finishing’.



Sheets used should be of 16 Gz; Square pipes used should be of atleast 25mm x 25mm x 16 Gz & st
ainless steel angles used
should be of 16 Gz; Wire mesh if used of AISI 304 quality SS wire of 2” x 1” x 10 SWG.



Having 1 or 2 handles (one ahead and another at the back),



If applicable, Top surface provided with curved skirting for utilizing as working
surface.



Two to Four Polyurethane swivel castor wheels; applicability with brakes in few.



All the joints will be welded with Argon Arc welding with Mat finish.



General Specifications for Waste Trolleys:

Made up of authentic heavy duty AISI 304 quality grad
e Stainless Steel; Complete Body in ‘Matt Finishing’; Sheets, angles, pipes, welding
and castor quality described as above.

May be designed with 3,4 or 5 castor wheels (as applicable) so that its carriage may be easily handled and wheel may rotate t
o provi
de
direction of movement.




Animal Cages Trolley (2):



Trolley with total THREE Shelves each of atleast 08 inch height and closed on sides by two covering doors (for opening and cl
osing)
with handle.



Having 2 handles (one ahead and another at the back; s
tays below the top margin of trolley), Top surface provided with curved
border/skirting (upto 0.5
-
1 inch height) for utilizing as working surface and further supported by wire border upto another 1 inches.



Trolley of total 36 inch Height, 40 inch Length an
d 26 inch Width (outside finished margins
-
excluding handles).



Trolley for Carrying Water Buckets (2):


82





Similar to cylinder trolleys for holding Plastic Buckets of 60
-
80 Lit Size; with single handle.



Tough enough to handle upto 60
-
80 lit of water weight.



C
astor wheels of appropriate size, quality and rotation for enabling its easy carriage and movement.



Castor Wheels to be aligned such that its travel direction may be coordinated for smooth carriage and transport (like front w
heel
drive)



The bottom base for

holding the bucket should be about 3
-
5 inches from the floor.



Provisions for providing chained or interlocking side supports to the water bucket.



Trolley for Animal Feed (2):



Trolleys with provision of Drum of size 30 inch height and 18 inch diameter hav
ing a separate lid with handle.



Total height of structure with handles should not exceed 5 feet.



Base with 2
-
4 Polyurethane swivel castor wheels and enabling easy movement at turns etc.



Tough enough to handle heavy weight and adequate side supports.



Trolle
y for Animal Waste (2):



Similar to cylinder trolleys for holding Plastic Buckets of 60
-
80 Lit Size; with single handle.



Tough enough to handle upto 80
-
100 kg of garbage weight.



Castor wheels of appropriate size, quality and rotation for enabling its carr
iage onto concrete road and cemented surfaces also.



Castor Wheels to be aligned such that its travel direction may be coordinated for smooth carriage and transport (like front w
heel
drive)



The bottom base for holding the bucket should be about 3
-
5 inches f
rom the floor.



Provisions for providing chain or interlocking side supports to the garbage bucket.



Trolley for Animal O.T. (1):



Trolley with Four Drawers; Top 2 drawers of 4
-
5 inch height and bottom 2 bottom drawers of minimum 8 inch height , openable fro
m
one side with tilted
-
in groove for opening



Top 2 drawer divided vertically into 3 partitions each;



Having 2 handles (one ahead and another at the back; stays below the top margin of trolley), Top surface provided with curved

border/skirting (upto 0.5
-
1
inch height) for utilizing as working surface.



Trolley of total 36 inch Height, 40 inch Length and 30 inch Width (outside finished margins
-
excluding handles).



Material Carrying Trolley (1):



Trolley with One Top Drawer of minimum 8 inch height and bottom t
o it is divided into two shelves each of atleast 12 inch height and
closed by two covering doors (for opening and closing) with handle and provision of lock.



Having 2 handles (one ahead and another at the back; stays below the top margin of trolley), To
p surface provided with curved
border/skirting (upto 0.5
-
1 inch height) for utilizing as working surface and further supported by wire border upto another 1 inches.



Trolley of total 36 inch Height, 40 inch Length and 30 inch Width (outside finished margins
-
excluding handles).

Note:
-

Only those firms applying for all t
rolleys will be considered

eligible
.

A
ny firms participating on
ly for partial trolleys may be t
echnically
disqualified.




Tender Group


Library


1.


Library Management
Software


Developed by r
eputed institution.


: Multi
-
User integrated, Field Proven software for unlimited collection.



83



: Ensure functionalities such as Acquisition, Cataloguing, Circulation, Serial Control, Web OPAC Search and various kin
ds of reports
management.


: Web ena
bled, user friendly, easy to use.


: Based on ISO
-
2709 specification, compliant to Z39.50, conform to international standards such as MARC21, Journals data in MARC 21 with th
e
feature of implementation of tag 856 for electronic resources, CCF etc.


: Inco
rporates Bar
-
Coding, Smart Card, (Add on option) RFID.


: Can operate on wide spectrum of Hardware and Operating Software.


: Compatible to 3 tier operating system architecture. (i) Server Option (UNIX, LINUX, WINDOWS,
-
95/98/NT/2000/XP), (ii) Client Optio
ns (Standard,
Windows 95/98/NT/2000/XP, Web enable, UNIX work station etc.), (iii) RDBMS options (SQL server, ORACLE, etc.


: Assure security by blocking the access of any function in any module for other users.


: Facility to Import and export data.


: So
ftware to be Robust (must not crash) and Scalable (to meet the growing activities of next 4to 5 years).


: Adequate On
-
site training to Library staff and Hand Holding support.


: After sale customer service support preferably from NCR (National Capital Reg
ion) for efficient complaint resolution.


: Up gradation and Enhancement through AMC.


: Its usage in leading Medical libraries in India and Compatibility with NML in view of plan for taking membership for e
-
consortium with NML. The
system should be fully
compatible with NML.


: Data Entry of Documents from Library Shelves to the automated system to be undertaken by the Vendor.






Tender Group


Ophthalmology


1.


A Scan

Biometer


Technical Specification;

General:



呯Tch screen user 楮ierface



Large h楧i Co
ntrast LCD



5
-
6 Progra浭ab汥luser profi汥



Portab汥lDes楧i



Scan v楥ier arch楶楮i software

A
-
Scan

Scan Modes:


84





Direct Contact/ Immersion



Manual / Automatic measurements


5 Examinination Modes:



Normal



Cataract



Dense Cataract



Aphakic



Pseudophakic (5 settings)



Re
view screen for A
-
scan / Measurement review capability

Measurements:



ACD: 1.5 to 5
-
6 mm,



Lens thickness:2
-
6 mm



Axial length: 15 to 40mm

Available IOL formulas:



SRK II; SRK
-
T; Binkhorst; Holladay; Hoffer
-
Q; Haigis; Post Refractive IOL Formulas: Larkany myop
ic regression: Aramberry
double

k

Immersion capabilities
:

Clinical accuracy +/
-
0.1mm;

Resolution: 0.01mm

Probe type:

Frequency: 10 MHz

-
Solid style probe and immersion should be available

Inbuilt LED for fixation light

Printer: inbuilt printer

Port for di
ect connection to PC

Power Requjreinents:
-

Voltage; 100
-
2240VAC

2.


Autoref
-
Keratometer
(Imported)


1.

Refraction range:
-
35D to +22D Spherical, upto +/
-
10D in cylinder.

2.

Keratometry:30 D to 67 D in 0.25D steps, 5
-
10 mm radius of curvature

3.

Corneal diameter:2
-
14 m
m

4.

Pupil diameter: minimum 2mm

5.

Refratometry and Keratomery mode, separate and combined

6.

Contact lens fitting simulation

7.

Adjustable chin rest

8.

Memory of Data: upto 10 readings per eye

9.


Auto
-
tracking mode: for X
-
Y
-
Z movement to track the patient’s eye automatic
ally.

10.

Color Mode
-

to be able to take the color images of the eye


85



11.

Retro
-

Illimination mode
-

to be able to view the retro
-
illumination view of the patients eye.

12.

Point Spread Function and acuity aberration calculations.

13.

Printer facility

14.

LCD color monitor

15.

P
ower supply: AC100
-
240 Volts

16.

Instrument table

UPS compatible with equipment

3.


S
lit Lamp Imaging
System
(I
mported
)


The slit lamp should have the following specifications:



Bright illumination using LED/ Tungsten filament / halogen bulb capable of giving ill
umination intensity upto 6,00,000 Lux.



Prismatic stereo microscopic with magnification from 6.3x to 40x with steps at 10x, 16x and 25x.



Diameter of the field of view should be from 3.1 to 32mm.



Slit length should be 1
-
8mm continuous.



Slit width should be 0
-
8mm continuous.



Filters available should be red free, grey, blue and heat absorption.



Eyepieces should be of 12.5x.



Facility to tilt the illumination tower upto 20deg.



Imaging and documentation software to enable image capturing and store/document the i
mages for future reference along with
the patient’s clinical data. It should give live display on the monitor for teaching purpose.



Digital camera module for image capture & live display.



Cold light source for background illumination.



Suitable dedicated PC should be provided for imaging software.



12 mega pixel resolution




1/1.8 inch CCD



Digital Still Imaging capability



Digital video at full resolution 1600x1200 capability



USB 2 high speed data transfer



True Aperture with frame rate 12.
5 f/s



Freeze technology and History trigger capability



DFC


depth of field / aperture control



Original hydraulic instrument table


86



4.


S
lit Lamp With
Applanation
Tonometer
(Imported)



Should have bright illumination using LED/ tungsten filament bulb / halogen

bulb capable of giving illumination intensity up to 600,000 Lux



Prismatic stereo microscope with magnification from 5
-
6X to 32
-
40X in zoom in steps.



Diameter of field should be from 30
-
40mm to 5
-
6mm.



Slit length 1 to 8
-
14mm continuous.



Slit width 0 to 8
-
14mm continuous.



Filters: blue, red free (green), grey (10%), UV and IR filters permanently installed.



Eye pieces of 10
-
12.5X.



Facility to tilt the slit image up to 20 deg. Should be available.



Facility for Assistantscope



Original Goldman Applanation tono
meter.



Original hydraulic instrument table



Adapter for inclined Eye piece to enable the viewing into the microscope




Constant voltage transformer compatible with slit lamp.



6 spare bulbs
.

5.


Synoptophore




Movement of optical tubes



Horizontal:+5 to
-
40



Verti
cal: Hyper 30 Hypo 30



Torsional: Incyclo 20, Excyclo 20



Slide illumination: Rheostat controlled 12V lamp for each slide. After image illumination by 12 lamp



Auto flashing: Auto flashing of slide illumination either simultaneous of alternate in



Slides with

hadinger brushes



Four spare bulbs



Motorize table with UPS back up

6.


Portable Tonometer

Based on rebound measuring principle, Light; portable; not requiring calibration, should be able to measure IOP in supine pat
ients. Range of IOP
-

-
7 to 50mm Hg, highl
y accurate & reproducible in children & uncooperative patients, able to measure IOP without topical anesthesia, rechargeable

battery. Spare probes with additional 100 disposable probes

7.


Flash Autoclave

(Imported)



Stainless steel chamber and door having s
trong joints and door latch



Outer dimensions: approx 24x20x16 inch; inner dimensions: 18 inch depth; 3 perforated stainless steel trays



With silicone gasket, digital temperature, pressure and sterilizing time indicator cum control



Operating temperature: 13
4 deg Celsius for instruments and 121 deg Celsius for linen



Individual buttons for different types of loads



Facility for temperature autocut out



Facility for autoreset sterilizing and drying timer; preferrably vacuum drying



Should be able to sterilize sta
inless steel as well as plastic instruments



Power:220 V


87



8.


Retina Surgery S
et




Castroviejo calipers
-
1



Castroviejo’s needle holder with lock
-
1



Castroviejo’s needle holder without lock
-
1



Muscle hooks
-
2



Artery forceps
-
5



Lim’s forceps
-
1



Colibri forceps
-
1



Westcott’s scissors
-
1



Serrated plane forceps
-
2



ILM forceps 20G
-
1



ILM forceps 23G
-
1




Curved vitreous scissors







20G

-
2



23

-
2




Horizontal cutting vitreous scissors
-
2



Vertical cutting vitreous scissors
-
2



Pick forcep
s
-
2



Foreign body forceps for removal of intravitreal foreign body
-
1



Silicone tip fluid needle for air fluid exchange or fluid


fluid exchange
-
2



Back flush needle
-
2



ERM removal forceps
-
2



30 G cannula
-
4



MVR knife
-
4



High speed Vitrectomy cutter with 2
500 cutting for 23 G=5

-
2



Trochar cannula set for 23 compatible with accurus 400 vitrectomy
-
2



Infusion cannula for vitreous surgery 20G, 23G
-
2



Endo light 23G
-
2



88



Tender Group


Dentistry


1.

Injectable GP
condensation


Three dimensional injectable Gu
ttapercha System

The Guttapercha cannules are warmed up in 3D heater and dispensed with a syringe into the root canal.

It contains high viscosity guttapercha, specially suited for transfer on an instrument into the canal easy, fast and precisel
y placed.

2
.

Conscious
Sedation Unit
Nitrous Oxide:
Oxygen sedation
system, with in
built safety
mechanism




It should be portable mobile with four cylinders two oxygen & two nitrous oxide cylinder.



It should have double mask scavenger system.



It should have automati
c vacuum switch provide safety
-

automatic on
-
off. The minute the gas begins to flow from the flow
-
meter the system activate the scavenger system, when the procedure is finished it automatically shut down the vacuum.



The scavenger system should be unique co
mpatable, quite and safe and help to promote office efficiencies and infection
control, these disposable or autoclavable latex free liners can be on and gone, while complying fully with infection control
protocol. Should be available for both adult and ped
o unscented or citrus scented



There should be portable tank stand for use with two tanks oxygen and two tanks nitrous oxide

height adjustable from 43
inches to 50 inches
.



Gas flow meter should be digitally controlled.

3.

Hydrosolder




Integrated booster m
ade of electrolyte resistant material



Meets high safety standards by working pressure and separate safety pressure control device, flame trap and thermally
controlled gas after flow locking device.



Reactor, 2 liters capacity


extremely long lifetime of th
e electrolyte.

4.

Dental Lab X ray
Film Automatic
Developer


1.

Produce technology:
The out casing are made of plastics mould. It's very stro
ng, durable and anti
-
corrode.

2.

Equipment Figure:
New designed small body and beautiful outlook.
Taking films very exp
ediently due films turn above.

3.

Inst
all & Adjustment: Occupy small ground, install very freely, fit any dark room and put it on the table directly.

4.

Film
-
Sending Frame: Safe Film
-
Sending systems come from one whole design, no films jamming or scratch.

5.

High
-
Effect Drying: New wind route technical can blow all little water spot on the films. At the high net surrounding, it can get
distinct clear cut films.

6.

Film
-
sending Board with Cover: Light and close film
-
sending cover board, operator may open lamp and lea
ve after enter films.
This design makes work easily and improves work effect.

7.

C
ritical Parts: The rollers’ material can resist high
-
temperate and crystallization. No change shape and swell for using long time.

8.

Circuit Control: Microprocessor controls heat
ing, automatic check and touch films, replenishing chemicals
.

9.

Energy
-
Saving
:

Keep sleep situation when no films need process after a while
.

Stop heating and rolling, then cut enter water.
This can save energy for max limit