“Thor IP” 3DES Fix Configuration instructions

gazecummingNetworking and Communications

Oct 26, 2013 (3 years and 1 month ago)

68 views

“Thor IP” 3DES Fix Configuration instructions



1.

Install the EPP (follow EPP Installation instructions). Connect the EPP to the ATM and connect the
special serial cable from the EPP to 3DES Fix’s serial port labeled “Keypad”.

2.

H
ook up the LAN connections (the direct Ethernet cable from the ATM plug into the “ATM” labeled
receptacle on the 3DES Fix box, the “Host” labeled receptacle connect to the external Host hub). You
should use a straight Ethernet cable to connect the ATM mac
hine to the 3DES Fix box, since the
“ATM” receptacle is already wired in crossover mode.

3.

Reconfigure the ATM’s TCP/IP parameters. Make sure you note the existing values of those parameters
as you will need to configure them in the 3DES Fix box later.


Par
ameter

New value

Old value

ATM IP Address

192.168.1.5


Host IP Address

192.168.1.6


TCP/IP Port number

8560 Axis or CM


Gateway Address

None


IP Address Mask

255.255.255.0



4.

Turn on the 3DES Fix box. Make sure the “OUT OF SERVICE
-

WAITING FOR CONFI
GURATION
MODE” screen appears on the ATM.

5.

When you see the “OUT OF SERVICE
-

WAITING FOR CONFIGURATION MODE” screen, quickly
press the ‘7’ key on the EPP several times (four times or more). The message on the ATM screen
should change to “OUT OF SERVICE
-

RECEIVING 3DES CONFIGURATION”. Wait for the 3DES
Fix Configuration Menu to appear.

6.

To enter the Configuration Menu you will need to type in the password (PASSWORD1: 121212,
PASSWORD2: 343434).

7.

When “3DES CONFIGURATION” Menu appears, choose option 1 to Ch
ange Master Keys. Use
PINVELOPE values
228228

for COMPONENT1 and
822822

for COMPONENT2.

8.

Once you have entered the Master Keys, return to the Main Menu and go to option 3, “TCP/IP
CONFIG”. You can view the current settings and enter the appropriate setting
s (the old value for
ATM
IP Address

will be the
3DES IP Address
, the old value for
Host IP Address

will be entered as
Host IP
Address
, the old value for
Gateway IP Address

should entered as
Gateway IP Address
, and the old value
for
TCP/IP Port

should be en
tered as
IP Port

in this menu).

9.

Exit the menus and wait for 3DES Fix to restart and complete the Load process. If you wish to speed up
the load process, press 1111 on the EPP when you see the “OUT OF SERVICE
-

WAITING FOR
CONFIGURATION MODE” screen. The
message should change to “OUT OF SERVICE
-

RECEIVING ATM CONFIGURATION”.