SN
Equipment
Code
Name of
Equipment
Specification
1.
MCHB001
Cardioc scope
with central
monitor
Cardio scope with monitor
Patient Multi
-
Para Monitor
Specifications
♦
Should have facility to display 12 leads ECG, RR, HR, SpO2, NIBP, 2 Temperature, as standard
parameters, with built
-
in rechargeable battery back up of 1 Hrs.
♦
Display : Should have minimum 14” or above color TFT touch screen display.
♦
Should be modular monitor with modular interchangeable facility .
♦
Should display at least 6 waveforms of sel
ected parameters simultaneously.
♦
Should have Nellcor/maismo/ FAST technology to sense the SpO2 in hypotensive, shivering &
motion condition.
♦
Should have Oscillometric Technology for measurement of NIBP with Auto, STAT and manual
modes.
♦
Should have d
ifferent patient type selection (From neonate to adult).
♦
The pulse rate should be displayed either with ECG or SpO2.
♦
Should be able to analyze arrhythmia & ST segments for all the leads.
♦
Should have facility for displaying multi
-
screen configurations
.
♦
Should be able to store & display 72 hours or more of graphical trends of all parameters.
♦
Should be suitable for monitoring adult, pediatric & neonatal patients.
♦
Should be able to give visual & audible alarms with three levels of volume adjustment
on violation
of any monitored parameter.
♦
Should have connectivity to Central station.
♦
Quoted model should be FDA/ CE / TUV approved. Authentic Certificate has to be submitted.
• optional : should have moduler upgradability for Etco2 ,multigas facility
and cardiac output , BIS ,
EEG , thermal recorder ,
♦
Should be supplied with:
• 5 lead ECG cable
–
1
• SpO2 (Adult) probe with extension cable
–
1
SpO2 (Pediatric) probe with extension cable
–
1
• NIBP Cuff with extension cable for Adult, Pediatric
and neonate
–
1 each
• Temperature (Skin) probe
–
2
disposable IBP transducer 2 no.
• Earthing Cable
–
1
• Power Cord
–
1
• Operating Manual
-
1
2.
MCHB002
AED Plus
Defibrillator
Should be operable by mains and battery
Mains
-
100
-
240volts AC (Auto ra
nging )Frequency 50/60 hz
Battery capable of usage for atleast 90 minutes or 40 discharge of 200 joules, Battery should be
rechargeable
Monitor/Display should have high resolution colour TFT screen size minimum of 6.4inch
Defibrillator should be Bi pahsic
truncated exponential optimised terminbating current impedance
compensated
Energy (External ) 1
-
10,15,20,230,50,70,100,120,150,170,200 joules (Internal) 1
-
10,15,20,30,50
joules
Should have AED Mode and Manual Mode
Should have facility for syncronised & man
ual defibrillation/cardioversion
Should be low energy bi phasic defibrillator and monitor with recorder having capability to revert
all arrhythmias within a maximum energy of 200 joules
Should monitor ECG through paddles, pads and monitoring electrode and
defibrillate through
pads and paddles
Should print the ECG on thermal paper of min 50 mm width
Shock delivery via multifunction defibrillator electrode pads or paddles
Should have external paddles with paddle contact indicator
-
for good paddles contact bot
h adult
& Peadiatric should be available recorder should have events summmary facility for recrding &
printing atleast 250 events & 50 wave forms Should capable of printing reports on events
summary,configurations , self test battery capacity etc.
should h
ave facility for self test/check before uses & setop functions record mode should be
manual& automatic non invasive pacing should have noninvasive extranal transtutanious pacing
by extranal paddles for both adult & pediatric mode of pacing both demand & s
ynchronous pulse
oximeter should have spo2 facility with adult spo2 finger probe,peaditric spo2 probe & spo2 ear
probe
NIBP monitering should have nibp monitoring facility for both adult & peadiatric
it should manual & automatic mode
there should be provi
sion for upgradeable to ETCO2
there should be optional USB port for data transfer & storages
system configuration , accessories , spares & consumables (A) defibilator (B) paddles Adult &
Pediatric patient cable, power cord, rechargeable battery , spo2 fing
er probe adult & pediatric,
spo2 ear probe 2nos each, nibp hose / tubing, nibp cuff adult & pediatric 2nos each, external
pacing pads adult & pediatric 2pair each.
should be US FDA or CE approved product
3.
MCHB003
Pulse
Oximeter
System should have:
1
High
-
resolution color TFT display of minimum 6” (diagonally) screen size.
2
Should display SpO2 values, PR value, and plethysmograph along with perfusion level indicator.
3
Should display online short trend for at least an hour.
4
SpO2 Range 1
-
100 %
5
Alarm Limits:
S
pO2
50
-
95 % (Low), 55
-
100 (High)
6
Adult to neonatal applications.
7
24 hours data storage facility in Tabular & Graphical mode with zoom facility.
8
Must have Graded & Color coded alarms (2 stage)
9
Alarm recall facility to view minimum last 15 alarms should be p
ossible
10
Inbuilt thermal array recorder facility.
11
Can be used as transport and ambulatory monitor.
12
External monitor or RS 232 option should be provided.
13
Mains and removable Lithium battery operation.
14
Conforming to International standards
–
IEC 60101
–
1
–
2
, CE.
Should be supplied with:
Reusable SpO2 finger sensor
4.
MCHB004
Laryngoscope
with blades
The set of four satin blades, includes:
Curved macintosh type, size: 1, 2 & 3.
Straight miller type, size: 1.
Spare bulbs
-
4 pcs.
Stainless steel satin handle us
es two alkaline batteries (medium size, 1.5v battery).
5.
MCHB005
Suction
Machine
heavy duty
Electric
Specifications :
Portable suction unit: size 38x17x28.5cm, weight 5.1kg
Description (e.g.: model Vario A/C, manufacturer Medela)
Technical specificati
ons: SUCTION MACHINE with pump:
-
Power supply: 230
-
240V/50Hz
-
Vacuum capacity: 18 litres/mim
-
Maximum depression:
-
75kPa (
-
563mmHg)
Vacuum is created by a plastic piston and cylinder system, with four vacuum
-
creating modules
(Quatro
Flex™ technology).
The membrane vacuum regulator permits accurate vacuum settings.
Double overflow
-
protection system (bottle and pump).
Working temperature range: +5 to +40°C.
SAFETY DEVICE:
The safety device protects the pump against overflow: suct
ion is interrupted when foam or liquids
reach the safety level in the small jar. All components are reusable and can be steam sterilized at
134°C.
A collector system with a single
-
use protection device has been added on request of the ICRC
COLLECTOR SYSTE
M:
Bottle or jar: 1 litre, graduated PSU (polysulphone)
Lid: Includes 1 overflow device, a 6x10mm diameter conical connector and 2 clips
Connection tube: Silicone tubing, diameter 12x7mm, length 25cm, and 2 connectors: 1 straight
and 1 curved 90°.
Suction tube: Reusable silicone tube: diameter 7x12mm, length 200mm.
Single
-
use tube: diameter 7x12mm, length 180cm.
Filters: Bacterial filters, single
-
use.
Unit presentation: Delivered with the following components:
-
1 suction machine and pump
-
2 one
-
litre bottles or jars, with lids
-
1 safety device
-
4 overflow spares
-
2 lid clip spares
-
2 suction tubes, non
-
sterile
-
2 suction tubes, sterile
-
1 spare fuse
-
1 user and maintenance manual, multilingual
Packaging: Box: 400x400x47
0mm
The following must appear on the pump packaging:
-
Manufacturer’s name and address.
-
Item designation, serial number, CE mark and reference number of notifying body.
Outer packaging: Manufacturer’s name; product name and serial number.
Other:
Complies with Medical Device Directive 93/42/EEC, class risk IIa or equivalent.
Manufacturer’s quality management system complies with ISO 13485.
Accessories
-
Spare parts
(Manufacturer Medela: model Vario 18 CA, 600.2601)
Code + description Pictures
Comments
XSEQSUCC3B
(suction, elec., vario) BOTTLE,
1L, psu, autoclavable
Liquid collector
-
volume content 1 litre
-
graduation scale 100ml
-
material polysulphone
sterelisable at 134°C .
XSEQSUCC3BL
(s
uction, elec., vario) LID w/ conn.6
-
10mm, + overflow device
Components:
-
1conical connector Ø 10
-
14mm
-
1 overflow protection device
-
2 blue plastic clip, for lid fixationXSEQSUCCM30B
LC
(suction, elec., b30/vario) CLIP for lid
clip, plastic, blue, for lid fixation
XSEQSUCCM30BLO
(suction, elec., b30/vario)
OVERFLOW protection device
Bottle /jar overflow protection device,
white
XSEQSUCC3S
(suction, elec., vario) SAFETY
DEVICE, for pump, Ref 2001733
Components
1 Botte/ jar 250ml, polisulphone
1 Lid with patient connector Ø 6
-
10mm, two
clips and one overflow protection device
2 Connecting tube, silicone
size: external Ø 12mm, internal Ø 7mm,
length 30cm + 2 connectors
All components are reusable and
autoclavable at 134°c
XSEQSUCCM30T
(suction, elec., b30/vario) TUBE
SUCT., d.12x7mm/2m, silicone.
SuctionTubin
g (between operation field and
suction machine) reusable
Size: external Ø 12mm, internal Ø 7mm,
length 2m
Material silicone,
Autoclavable at 134°C
MCTDTSUCC25
TUBE, SUCTION MACHINE, CH
25, 1.8m, sterile, s.u.
Suct
ionTubing (between operation field and
suction machine) single use
Size: external Ø 12mm, internal Ø 7mm,
length 1.80m, with manual vacuum control
connector
XSEQSUCC3U
(suction, elec., vario) FUSE T
800 mA, dia.5x20mm
Fuse T 0.8 A Ø 5.0 x 20 mm
Accessories not included in standard version 2009, can be ordered separately as option ICRC
Code + description Pictures Comments
XSEQSUCC3A
(suction, elec., vario) BAG, transport
-
Made of strong resistant
waterproof textile
-
Multi pocket bag allowing to
store accessories
XSEQSUCC3R
(suction, elec., vario) TROLLEY, w/
2 fix.rails, Ref 0770511
Material: stainless steel
2 standard rails 10x25mm
4 swivelling antistatic castors, 2
with breaks
XSEQSUCC3RC
(suction, elec., vario, trolley) CLAMP
HOLDER, Ref 0770821
Support fixation clamp, for rails
10x25mm
XSEQSUCC
3F
(suction, elec., vario) FILTER, antibacterial/overflow, s.u
Overflow protection /bacterial
filter is compulsory for the
suction model not equipped with
reusable safety device (for
ICRC all XSEQSU
CC3
delivered before 2009)
Note:
When ordering technical spare parts aleays mention, suction apparatus model, and serial
Number
6.
MCHB006
Elect. Cautery
Machine with
Bipolar facility
Salient Features
Powerful and relatively charr free bipolar coagulatio
n
Step less variation of output power
Audio and visual indication for foot switch activation
Highly portable unit
Autoclavable accessories.
Inbuilt voltage stabiliser
Special power transformer for non
-
interference with other monitoring equipment
Optional
Various shapes of Bipolar forceps suitable for specialized surgical needs
StandardAccessories
Colour coded single pedal footswitch with receptacle
Insulated Bipolar forceps with connection cable (Autoclavable)
Technical Specifications
Bipolar Coagulation P
ower : 100 Watts
Rated frequency : 1000 KHz
Power supply : 230 Volts, 50 Hz
Line Voltage Fluctuation Compatibility
Working range : Line Voltage from 150 to 270 Volts
PhysicalDimensions
Unit size : 304 x 180 x 123 mm
Unit gross weight : 4.5 Kgs
7.
MCHB007
BA
TTERY
OPERATED
DRILL SYSTEM
WITH
VARIOUS
ATTACHMENT
Cannulated AO Drill
–
Fully cannulated (3.2mm) with variable
Speed (0
-
1200 rpm)
Separate trigger drive for clock wise &
Anti clock wise direction
Double loose pin fully autoclavable
Radiolucent drive &should accept all
Attachment
1.
Jacobs chuck with key
–
cannulated with variable opening from 0
-
6.5mm
2.
Quick coupling
-
For drill, tap, screw, medullary and Acetabular reamer attachment.
3.
Quick coupling
-
For ‘K’wire upto3.2mm.
4.
Quick coupling
-
For DHS/DCS reamer.
5.
Radiolucent drive for drilling of distal interlocking holes.
6.
Drill bit for radiolucent drive of 2 to 4 mm diameter.
7.
Oscillating saw attachment with variable amplitude 2.5
o
to 5
o
with oscillating frequency from
12500/min to14000/min
8.
Oscillating saw blade with cutting thickness from .5 to 1.5thickness.
9.
Reciprocating saw attachment with blade of 1.1 to 1.2mm thickness.
10.
NiMH/NiCd battery with rating at least 1.5 mAh. Separate batt
ery for drill and saw with one
spare battery each.
11.
Battery charger with capacity to charge 4 batteries simultaneously and input voltage 220
-
240v.
12.
Flexible cannulated reamers
-
various sizes (5 mm to 14 mm, in 1mm increment)
Oscillating drill attachment f
or converting continuous rotatory movement to back and forth
8.
MCHB008
Image
Intensifier
with C
-
Arm &
Memory &
Specifications
Fully microprocessor based system with feather touch panel,image intensifier, microprocessor
based control wit
h touch panel
Printing
facility
System description :
-
fully microprocessor based system with feather touch panel
Image Intensifier
:Thomson / Toshiba 6 imaging system with High performance capability.
Generator
:
X
-
Ray
Tube
-
Head
:
Collimated X
-
Ray output through im
ported x
-
ray tube with following features:
Dual focii having 0.6mm and 1.8 mm Focus
Anode heat storage capacity 30KJ, Anode cooling rate 250w
Power Input:
220
V
, 1 Phase, 16 Amps, 50 Hz.
Generator Rating
:
Microprocessor based control with feather Touch Panel
.
Generator Surgipix IIC unit delivers Excellent radiography.
Radiographic output from 40mA to 100mA
Fluoroscopy 0
-
5 mA (as per kvp selection) variable in steps of 0.1 mA.kvp variation from
minimum
40 kvp
to 100 kvp in steps of 1 kv
Line voltage compen
sation:
Stabilized 230V output at supply line voltage of 180V to 270V.
Additional short circuit protection with auto trip Feature.
Control features:
Fully Microprocessor based digital voltmeter for indicating Mains supply
voltage.
Digital kvp meter displa
y.
Digital mAs display.
Digital mA meter display.
Digital radio timer display.
Foot
-
switch for spot operation
Feather touch keyboard with appropriate led indications.
III.
Mechan
Smooth manual
-
control of front and back wheel steering for easy operation.
Mot
orised C
-
arm control with smooth up and down movement.
Well balanced C
Smooth manual horizontal travel, panning & C Rotation.
Trolly for T.V. Monitor with easy movement.
C
-
ARM
Features
:
Rotation :
360
0
*
Source to I.I. Distance
:
90 cms.
*
Arc orbital movement
:
110
0
*
Panning
:
25
0
*
Horizontal travel
:
23 cms.
*
Vertical motorised
:
35 cms.
*
Movement Detachable
*
Cassette holder
:
10 X 12
or 8 X 10 film.
TV
Monitor
: 15/17 B/W, 625 lines, 50hz, 230v Ac with high resolution display capability 2 numbers
monitor supplied.
* IMAGE MEMORY:
*
32 Frame Memor
y With Dual Video Output And Frame Averaging.
*
Step
-
Wise Image Integration.(2/4/8/16)
*
Image Reversal Positive/Negative
*
Pulsed Fluroscopy
*
Image Resolution (512 X 512) Pixles.
*
Dynamic Storage Of Imag
e
∙
Digital Display For Image Selection
*Image Memory:
Memory a nd Da t a ba s e
1.
Acquisition is up to 25 frames/sec (selectable in increments of 1).
2.
50 cine
-
loops (1 cine
-
loop = 200 Images) are stor
ed in temporary memory before saving
it in permanent storage. Hence an addition of about 10,000 images to the total memory mentioned
in next point.
3.
Total storage: 25,000 Images + 405 cine
-
loops or 105,000 Images for permanent storage
in
basic system.
4.
Storage of cine
-
loops with frame
-
by
-
frame viewing and images.
5.
Auto run of the cine
-
loop.
6.
Patient information database to store, manage, retrieve Patient, Procedure, Image and
Cine
-
l
oop information stored in the system.
7.
Image Mosaic or Multi
-
map to allow thumbnail viewing of images for quick access.
Query the database using key words
8.
Post Image Processing like images rotation, zooming, panning,
measurements,
annotation, edge sharpening, pseudo colouring etc.
9.
MCHB009
Ventilator
High End Ventilator Specifications:
1.
Description of Function
1.1
ICU ventilators should provide artificial respiratory support to the critical patients in all the
types of
Intensive Care Units with altitude compensation for volume and BTPS correction for monitoring.
2
Operational Requirements
2.1
It should be microprocessor Controlled ventilator with integrated facility for Ventilation monitoring
suitable for Neon
atal (including premature) to adult ventilation.
2.2
The unit should be external compressor based for precise gas delivery ( not a turbine / piston/
blower based) .It should have proximal flow sensor for neonatal patient category only .
Demonstration of
the equipment is a must.
3
Technical Specifications
3.1
Hinged arm holder for holding the circuit
3.2
Should have Colored Touch screen, 12 Inch or more
3.3
It should have facility to measure and display ( inbuilt )
a) Mainstream End tidal CO2 with Capn
ography ( Optional) with monitoring of PeSO2, Vmin VCO2,
Curve Co2/ time, Alveolar ventilation , expire Co2 ( VTCo2) ,Vhigh and low alarms etc
b) 3 waves
-
Pressure and Time, Volume and Time and Flow and Time.
c) 3 loops
-
P
-
V, F
-
V, P
-
F with facilit
y of saving of 4 Loops for reference.
d) Graphic display to have automatic scaling facility for waves
e) Status indicator for Ventilator mode, Battery life, patient data, alarm settings, clock etc
3.4
should have Trending facility for 72 hours
3.5
should
have Automatic compliance & Leakage compensation for circuit and ET tube
3.6
should have Following settings for all age groups.
a) Tidal Volume 5 ml to 2500 ml
b) Pressure (insp) 2
-
100 cmH2O
c) Pressure Ramp/ Flow patterns
d) Respiratory Rate 1 to 150 b
pm, Insp. Time 0.1 to 3 sec, I : E Ratio 5:1 to 1:599
e) Insp. Flow ( resultant) 0.2 to 180 LPM, continuous Flow 2
-
40 lpm ( in TCPL ode)
f) CPAP/PEEP 0
-
50 cmH2O
g) Pressure support 2
-
100 cmh2O
h) FIO2 21 to 100%
i) Pause Time 0 to 2 sec
j) Flow Trigger 0.
2 to 15 lpm . Pressure Trigger 0.5 to 20 cmH2O
k) Expiratory trigger 5
-
80
-
% of flow
3.7
should have ,monitoring of the following parameters
a) Airway Pressure (Peak & Mean)
b) Tidal volume (Inspired & Expired)
c) Minute volume ( Expired)
d) Spontaneous Mi
nute Volume
e) Total Frequency
f) FIO2 dynamic
g) Intrinsic PEEP and PEEPi Volume (or trapped Volume)
h) Plateau Pressure
i) Resistance ( Rinsp & Rexp)& Compliance ( Cdyn & Cstat)
j) Use selector Alarms for all measured & monitored parameters
should have
following modes of ventilation
a) Volume controlled
b) Pressure Controlled
c) Pressure Support
d) SIMV (Pressure Control and volume control) with pressure support
e) CPAP/PEEP, PSV + assured tidal volume
g) Advanced mode like pressure controlled volume
guaranteed
( PRVC)
h) Non Invasive ventilation
i) MMV+PSV
j) APRV
k)Special Neonatal modes
-
TCPL, SIMV +TCPL + PSV, N
-
CPAP
( with continuous flow) , PRVC,APRV,and above mentioned mode
3.9
should have Apnea /backup ventilation
3.10
Expiratory block sho
uld be autoclavable and no routine calibration required
3.11
should have ,monitoring of the following parameters
a. Intrinsic Peep & Intrinsic PEEP Volume ( Trapped Volume)
b. Occl
usion Pressure( P0.1) , Max Inspiratory pressure (Pi max)
c. Non
-
forced Slow Vital Capacity , physiologic Dead space, RSBI, Imposed work of Breathing (
WOBi), Expiratory Time constant
( Tcexp)
d. Facility to calculate lower and upper inflection point ( P/
V Flex points)
e. Facility for ET Tube and Patient circuit compensation
3.12
should have Nebuliser with capability to deliver fine particle size of to be used in On line
3.13
should have Ideal Body Weight facility
3.14
should integrated Battery back u
p for minimum 2 hour for main unit
3.17
RS 323C interface for communications with networked devices.
4
System Configuration Accessories, spares and consumables
4.1
ICU Ventilator with trolley
-
01
4.2
Adult , Pediatric , Neonatal autoclavable silico
ne patient breathing circuits
-
02 each
4.3
Reusable and autoclavable Flow sensor and exhalation valve
-
2 each
Proximal Flow sensor for neonatal use
-
5 nos
Hinged Support Arm
-
1no
Air and Oxygen Hose
-
each 1 no
Optional Accessories
4.4
Medical Air
Compressor
4.5
Reusable Masks (Small, Medium, Large) with each machine.
-
02 sets ea
4.6
Humidifier
-
Servo controlled with digital monitoring of inspired gas temperature complete with
heating wire
-
01 ( Optional)
4.7
EtCo2 Sensor ( reusable)
-
1 no
Inlet r
equirement
5.1
Power input to be 220
-
240VAC, 50Hz
5.2
Gas input( air and oxygen)
-
50
-
100 psi
6
Standards, Safety and Training
6.1
Should be US FDA / CE approved product
6.2
Demonstration of quoted equipment model is a must.
6.3
Should have local se
rvice facility .The service provider should have the necessary
equipments recommended by the manufacturer to carry out preventive maintenance test as per
guidelines provided in the service/maintenance manual.
6.4
Comprehensive warranty for 1 year and provi
sion of AMC for next 5 years.
10.
MCHB010
Multipara
Monitor
Should have facility to display ECG, RR, HR, SpO
2,
NIBP, single Temperature, as standard
parameters, with built
-
in rechargeable battery back up of 1 hrs.
Optional upgrades: dual channel Invasive
blood pressure, EtCO2 measurement, multi gas
monitoring and recorder with built
-
in rechargeable battery back up of 1 hrs.
Display: Should have minimum 15” or above color TFT display.
Should display at least 10 waveforms of selected parameters simultaneou
sly.
Should have Nellcor technology to sense the SPO2 in hypertensive, shivering & motion
condition.
Should have Oscillometric Technology for measurement of NIBP with Auto, STAT and manual
modes.
Should have different patient type selection (from neonate t
o Adult).
The pulse rate should be displayed either with ECG or SpO2.
The respiration rate should be calculated through Impedance method
Should have single skin temperature monitoring either in
0
Celecius or
0
Fahrenheit.
Should be upgradeable to dual skin t
emperature monitoring.
Should be able to analyze arrhythmia (18 types) & ST segments for all the leads.
Should have facility for displaying multi
-
screen configurations (Standard, NIBP review, BIG
numerics, Short trend, 7 leads, 12 leads, OXY
-
CRG, Other
bed).
Should be able to store & display at least 96 hours of graphical trends of all parameters.
Should be suitable for monitoring adult, pediatric & neonatal patients.
Should be able to give visual & audible alarms with three levels of volume adjustment o
n
violation of any monitored parameter.
Should have connectivity to Central station through Wireless Station.
Nurse call function should be included as standard configuration.
Facility of bed to bed remote monitoring when connected via Ethernet to central
monitoring.
Should have software’s like Drug dose calculation and OXY
–
CRG as standard.
Quoted model should be FDA,CE, ISO/ TUV approved compulsory. Authentic Certificate from
has to be submitted.
Should be supplied with:
o
5 lead ECG cable
–
1
o
SpO2 (Adult)
probe with extension cable
–
1
o
NIBP Cuff with extension cable for Adult, Pediatric and neonate
–
1 each
o
Temperature (Skin) probe
–
1
o
Earthing Cable
–
1
o
Power Cord
–
1
o
Operating Manual
–
1
11.
MCHB011
Syringe pump
Syringe Pump
Programming systems
a)
Flow rate
b)
F
low rate and volume
c)
Flow rate and volume
d)
Volume over time; the pump automatically calculates the Flow rate
Automatic syringe
-
size detection
Adjustable occlusion pressure and ABS
Simple and safe BOLUS function
Full rechargeable battery
Full information abou
t the infusion status
12.
MCHB012
Infusion
pump
Infusion Pump
Flow Rate range:
a)
0.1 to 99.9 ml/h (in 0.1 ml/h increments)
b)
100ml/h to 999ml/h (in 1ml/h increments)
Accuracy: 5% with assigned IV set
Total Volume Range: 1 to 9999 ml or no limit
Purge Flow Rate
: 700ml/h (or selectable)
Alarms and Indicators:
a)
Air in Line
b)
Infusion complete
c)
Occlusion (Up/down)
d)
Empty container
e)
Low battery
f)
Door open
g)
Tubing misleading
h)
Other device malfunctions
Function:
a)
Keep
-
sensor
b)
Drop sensor
c)
Tubing clamp mechanism
d)
Broad range of de
livery rate settings
e)
Volume memorize function
f)
Selectable one shot purge
g)
Easy replacement of battery & convenient battery indicator
h)
Free drop protection finger
i)
User selectable setup (IV set, sound, occlusion, etc.)
Power Requirement: AC 100 to 240 V, 50/60h
z, External 12V DC, Power consumption: Less than 30
VA
Classification: Class I, Type BF, IPX 1
Battery Source: Rechargeable Nickel
-
Metal Hybride
Battery can run the pump continuously for about 3 hours at an operating rate of 25ml/h
Accessories: AC power,
IV Sets, Operating Guide
132)
)Infusion pump
13.
MCHB013
Oxygen
concentrator
Input Voltage
-
120 VAC ,
Input frequency
-
60Hz ,
Average power consumption
–
350 Watts
Oxygen concentration (at 5 LPM)
–
93% ,
Litre flow
-
31lbs (14kg) ,
Oxygen percentage
indicator alarm level
–
low ,
Oxygen
-
82% ,Very low oxygen
–
70% ,
Operating Humidity
-
95% ,
Concentrator Accessories
—
,
Compressor intake filter , Micro disk filter ,
Humidifier Connector tube
—
2 ,
Flow meter
-
2, for two patients at the same
time133)
14.
MCHB014
Electronic
Pneumatic
Tourniquet
(fully
automatic
micro
controller
based, with
dual cuff for
orthopaedic
operations
-
The electronic tourniquet should have digital display of time duration and cuff pressure.
-
It should have feather touch
electronic switches.
-
It should have battery backup so that pressure is maintained even in case of power failure.
-
Online decrease or increase of pressure should be possible.
-
Should have positive locking connector.
-
Should have noiseless operation.
-
Sh
ould afford quick pressurization of cuffs.
-
Should not require external high pressure.
-
Should have Dual cuff operation .
-
There should be an autoclavable silicon cuff and coiled expandable puncture resistant P U tubing.
-
An extra cuff and tubings should b
e provided.
-
The cuff pressure range shoul be from 10 to 450 mm of Hg.
-
Pressure regulation:+/
-
10 mm of Hg.
-
Timer could be set to wide range of 1 hour to 9 hours.
-
There should be an audible alarm on timer reaching set value.
-
It should have a memory fun
ction i.e.pressure set in last session is stored and displayed when
machine is switched on again.
-
Power supply:230 V,AC.,50+/
-
10%.,Built in battery for 3 hour back up,should work on generator
without the need of a voltage stabilizer.
-
Should have 1 year w
arrenty againt manufacturing defects including cuffs.
-
Should be light weight as little as 4 kilos.
-
SIZE: Length215mm,Height 100mm,Width 190mm.
-
Cuff sizes:Large: 33”,5”
Big : 24”,4”
Medium: 18”
,3”.
Small : 11”,3”
Pediatric: 8” 2”.
-
Should able to bear temperatures as high as 110*c for autoclaving.
15.
MCHB015
Blood gas
analyzer with
expenses of
reagents
Technical Specifications:
Equipment interface :
240 X 128 dots LCD display with soft key pad
Analysis principle : Direct "flow Thru" electrodes
Sample volume : ≤200µ
Sample type : Whole blood, serum, plasma.
Sample application : Sample cup, capillary or collection tube
Throughput : 65 samples / hour
Calibration : Automatic two
-
point calibration with additional option for carrying out one
-
points an
d two
-
point calibration manually
Pre adjusted standby mode with automatic calibration steps
Quality control : 2 different levels of quality controls
Printer : Built in stationary head graphical thermal printer
Storage Capacity : 1000 samples
Interface port
: RS 232
Power : 110 230V AC, 50/60 Hz
Dimensions : 452(H) X 452 (W) X 500(D) mm approx
Equipment weight : 15 kg approx
Operating environment : 15º to 30 ºC , 20% ~ 80% RH, 86 ~ 106kPa
16.
MCHB016
Oxygen
Cylinder kit
One Aluminium Cylinder with Regulator, P
ressure Gauge, Flow Meter and humidifier with
mask Oxygen in
Lts.
-
100 Lts (0.1 m
3
)
Weight of kit
-
1.3kg.
Flow Rate
-
0
-
4 Ltrs/Min
Three Aluminium Cylinder with Regulator, Pressure Gauge, Flow Meter and humidifier with
mask Oxigen in
Lts.
-
300 Lts(0.3
m
3
)
Weight of kit
-
3.7kg.
Flow Rate
-
0
-
4.5 Ltrs/Min (Each cylinder flow is set on 1.5L/Min)
Aluminium Oxygen cylinder with 5 Cylinder with Regulator, Pressure Gauge, Glow meter and
humidifier and mask. Stand with tubing
Oxygen
-
500 Ltrs (0.5 m
3
)
Weight
-
5.7 kg
(Flow is set on 1.5L/Min)
Features:
Easy to Operate
Quick Application
Portable Light Weight
Refillable
Economical and Long Lasting
Quality Product
Can be a life saver
An excellent life
-
long healthy gift
Service to the patient
17.
MCHB017
Operation
t
able Hydrolic
with
radiolucent
top with all
ortho, and
neuro,
attachments
Salient features SI
-
112 Surgical Operation Table Hydraulic Side end Control:
Simple action hydraulic pump controlled by a foot pedal
Fully S.S. covered base mounted on heavy duty cas
tors with auto floor locking system the
detachable leg section provides easy lithotomic positioning
Five sections S.S. top with large perineal cutout for drainage tray, built in kidney bridge
The improved hydraulic system provides smooth movement and the s
peed of lowering the
table is permanently set
The table is finished with extra head, permanent finish oven baked paint and all the accessories
are bright chromium plated
Standard accessories:
Anesthetic frame
Padded side supports
Intravenous arm board
Pad
ded shoulder supports
Lithotomic leg holder with straps, footrest with S.S. top
Optional accessories:
Water proof rubber mattress
Radio
-
graphic top
Neurosurgical attachment
Geopel type lithotomic clutches with straps
Orthopedic attachment
Technical dat
a:
Length of the table top: 190 to 200 cm
Maximum height: 95 + 5 cm
Longitudinal tilt: 30 +1
Width of the table top: 50 cm
Hydraulic lift: 22 cm
Minimum height: 80 + 5cm
Lateral tilt: 20+2
18.
MCHB018
Emergency
crash cart
1. Overall size shall be more than 9
00mm L x 500mm W x 1500mm H.
2. The crash cart should be made of 25.4mmx18G Stainless steel tubular frame work.
3. Shall have Epoxy / Anti
-
Microbial powder paint inside and out
4. Should have dual push handles on either side
5. Should have S.S. shel
ves, six colored removable bins & two polystyrene lockable storage units
with three drawers each.
6. Facility to carry ECG Monitors, Defibrillators etc on open areas at top centre and bottom
shelves.
7. Should have Stainless steel saline rod fixed wit
h.
8. Two accessory mounting brackets to mount accessories anywhere without the need of
prethreaded holes.
9. Crash cart should be mounted on 12.5 cms dia non
-
rusting swiveling castor wheels. Two
having locking arrangement.
10. Oxygen cylinder stand
epoxy powder coated, on one side
19.
MCHB019
Emergency
Hydrolic
trolley
Overall approx Size: 1800mm x 675mm x 750mm
Frame work made of rectangular M.S. tubes
Stainless Steel top in 3 sections
Trendlenburg positions adjustable by Screw/pneumatic gas spring
system.
Backrest section adjustable on rachet
Leg end section can slide under the main section
Height adjustable a pair of knee crutches
Pre Treated and Epoxy powder Coated.
20.
MCHB020
Auto analyser
Description of Function :
Used for the extraction and det
ermination of hydrogen cyanide (HCN) in
the total particulate matter (TPM) and gaseous phase of tobacco smoke by
an automated continuous flow analyzer. This method is applicable for the
testing of cigarettes and bidis .Also for determination of Nitrate
,
Reducing Substances, Reducing Carbohydrates in Tobacco
Operational Requirement;
Autoanalyser complete with colorimeter, auto sampler and other accessories
suitable for HCN estimation.
Technical Specifications:
Should comprise of the following:
•
Autosampler.
• Peristaltic Pump
• Nitrate Manifold designed for AutoAnalyzer used.
• Single Channel Colorimeter equipped with 15 mm flow cell and 550
nm filter /RP18 5 µm, 250 mm X 4 mm Chromatographic HPLC
Column
• Sampler
-
Random access sampler wi
th throughput of more than 150
samples in cups or tubes.
• Manifold
-
Should include applications for Hydrogen Cyanide
measurements.
• Flowcell
-
Should be having bubble through the flow cell operation.
• Colorimeter should be suitable for Hydrogen Cyan
ide analysis
Environmental factors:
1. The unit shall be capable of being stored continuously in ambient temperature
in the range of 0
-
50 deg C and relative humidity in the range of 15
-
90%.
2. The unit shall be capable of operating continuously in ambie
nt temperature in
the range of 10
-
42 deg C and relative humidity in the range of 15
-
90% .
Power Supply:
1.Power input to be 220
-
240VAC, 50Hz fitted with BIS plug (ISI mark)
2.UPS of suitable rating with voltage regulation , spike protection and 60 minute
s power back up.
Standards, Safety and Training:
1. Should be FDA/CE/UL/BIS approved product.
2. Manufacturer should have ISO certification for quality standards.
3. On site Comprehensive training for lab staff and support services customer
satisfacti
on with the system.
4. Comprehensive warranty for 2 years and 5 years AMC after warranty.
5.Shall meet IEC
-
60601
-
1
-
2:2001(Or Equivalent BIS) General Requirements of
Safety for Electromagnetic Compatibility or should comply with 89/366/EEC; EMCdirective
6. The bidder shall assure supply of spares for a minimum period of 10 years from the date of
supply
Documentation:
1. User/Technical/Maintenance manuals to be supplied in English.
2. Certificate of calibration and inspection.
3. List of Equipments ava
ilable for providing calibration and routine Preventive
Maintenance Support as per manufacturer service/ maintenance manual.
4. List of important spare parts and accessories with their part number and
costing.
5. Log book with instructions for daily, w
eekly, monthly and quarterly maintenance checklist. The
job description of operators and service engineers should be clearly spelt out.
6. Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning
the page/para number of
original catalogue/data sheet. Any point, if not substantiated with
authenticated catalogue/manual, without which it will not be considered.
7. Current user’s / performance list to be provided
21.
MCHB021
X
-
ray
machine
portable
100MA
Product Description
1
00mA medical mobile x ray machine YSX0410
GENERAL
1. Used in ward and emergency treatment room for radiography.
2. Combined X
-
ray generator.
3. Single focus, bridge rectification.
4. It is precise safe, reliable and flexible.
5. Remote control device
(control range≥ 5m)is used.
X
-
ray generator
Stationary anode, single focus and bridge silicon rectification.
The x
-
ray generator is an oil
-
immersed self
-
cooled unit.
Max rated capacity
Current
15
mA
30
mA
60mA
100mA
Voltage
90k
vp
90k
vp
90kvp
80kvp
Tim
e
6.3s
6.3s
4.0s
3.2s
Power supply
Voltage
180
-
240V
Frequency
50Hz
Capacity
Not over than 7KVA
Intemal resistance
Not larger than 1Ω
Voltage adjustment range
of x
-
ray tube
50
-
90KV
Range of the time
0.08
-
6.3s
Distance between the
focus to the grou
nd
700
-
1780mm
X
-
ray tube focus
transverse rotation
±60°
Specification of x
-
ray tuble
Model XD42.9/100 fixed anode, single focus 1.8/4.3mm
Transport
dimension(L×W×H)(mm)
1230×900×2050
Weight(kg)
Net:159/gross:256
22.
MCHB022
Ultra Sound
System 4 D
with
colour
duplex
Specifications
Imaging modes
l
B,2B,4B,B/M, M
l
CFM
l
PW Mode
l
Power Doppler/Directional PD
l
Duplex
l
Trapezoidal
l
Real
-
time 4D (Option)
l
Chroma B/PW
Probes
l
3.5MHz Convex probe
l
7.5MHz Linear probe
l
6.0 MHz Transvaginal pro
be
l
4.0MHz 4D Volume probe
l
7.0MHz Transvaginal probe(180°)
l
3.0MHz Micro
-
Convex probe (adult Cardiac)
l
5.0MHz Pediatric probe
l
Wideband, Multi
-
frequency
Image processing technology
l
THI on convex probe
l
Speckle Reduction Algorithm (SRA)
l
C
ompound technology
l
I
-
image: image optimization software
Measurement & Report packages
l
OB&GYN
l
Vascular
l
Urology
l
Small parts
l
Basic cardiac
Professional Clinical Applications
l
Abdominal
l
Obstetric
l
Gynecology
l
Vascular and Small parts
l
Pediatric
l
Urology
l
Musculoskeletal
Standard Configuration
Main unit, 15’’ LCD, 2 probe connectors, Hard disk, 2USB ports, Video out, TV out, LAN port, VGA
out
Options
l
3.5MHz Convex probe
l
7.5MHz Linear probe
l
6.0 MHz Transvaginal probe
l
7.0MHz Transvaginal probe(180°)
l
3.0MHz Micro
-
Convex probe (adult Cardiac)
l
5.0MHz Pediatric probe
l
4D package: including 4.0MHz 4D volume probe, 4D software and 4D hardware module
l
Video Printer: SONY UP897MD
l
PC Printer (any type)
l
DICOM 3.0
l
I
-
image: image optimization software
l
Biopsy kit: for convex, linear, TV prove
l
Foot
-
switch
23.
MCPTR023
PROSTHETIC
AND
ORTHOTIC
ELECTRIC
OVEN
•
Spare double walled, inside chamber made of stainless steel and out side made of mild steel
•
Heating is unifo
rm all around through high speed circulating fans
•
Toughened glass window on both doors
•
Supply with trays and inside stand for drape frames
•
Power supply 220
-
230volts single phase
•
60 x 75 x 50 cm
–
WXHXD
•
Temp 250
-
300*C digital Timers
•
Digital timer with alarm
24.
MCPTR024
ROUTER WITH
STAND &
ATTACHMENT
•
2.5 KW OR 2hp, 2800RPM with spindle, pedestal and starter.
•
Shaft length
-
350mm at inclination
•
Working height
-
850
-
900mm
25.
MCPTR025
HEAT PAN
WATER
HEATER FOR
LOW
TEMPERATUR
E
THERMOPLAS
TICS
•
65 x 10 x 50 cm(WxHxD) w
ith uniform heating
•
Body made of stainless steel both internally & externally
•
Digital indicator cum controller
•
Temp. range upto 80c
-
100c
•
Digital indicator cum controller
26.
MCPTR026
COMBINATIO
N GRINDER &
POLISHER
•
Grinding Stone: 20” Dia fitted on left sid
e
•
Shaft/spindle:2200
-
2400mm, long tapered fitted on right side
•
2Hp motor, rpm
-
2800
-
3000, Single Phase,
27.
MCPTR027
HAND
DRILLING
MACHINE
•
Drilling Dia
-
In 1
-
13mm
•
Pwer
-
50
-
600W
•
Speed
-
2500
-
3000rpm
•
Weight upto 2
-
2.5kg
28.
MCPTR028
HOT AIR GUN
•
Temp 100
-
600*C
•
Air fl
ow rate
–
350/550cpm
•
Power input
-
2000W
•
Weight 700gm
-
1kg
29.
MCPTR029
JIG SAW
•
Power input
-
500
-
600W
•
No load stroke
-
500
-
3000/min
•
Cutting depth in wood
-
80
-
90mm
•
Weight
-
1.5
-
2.5kgs
30.
MCPTR030
PILLAR
DRILLING
MACHINE
•
1” drill capacity
•
ISI mark drill chuck, arb
our and V belt
•
Adjustable drilling platform
•
4 drilling speed
•
single phase
•
RPM range 1500
-
2500
31.
MCPTR031
OSCILLATING
SAW
•
Ergonomic design with complete kit(Includes different attachment blades, spanner, fuse)
•
Circular blade with depth control gauge
•
Approxi
mate 25000
-
28000rpm
•
Effective for synthetic plaster and POP
32.
MCPTR032
ORTHOTIC
STAND FOR
MOULDING
•
Mild steel frame, 1000
-
1200 mm in height with platform for floor mounting
•
Suction mandrel made of mild steel heavy duty solid rod with 50 mm outer and 28 mm
inner
dia with brass ball valve.
•
Five planes adjustable alignment jig
33.
MCPTR033
HIGH
VACUUM
SUCTION
UNIT FOR
THERMOPLAS
TIC
MODULDING
•
Capacity
-
600
-
700mm hg, flutter free vacuum control knob
•
Pump type
–
double rotary vane pump
•
Jars are wide mounted 2 x 2
ltrs
•
Single phase 230
-
240 volts
•
Noise level very low
34.
MCPTR034
LINISHER
(BELT
SANDER)
•
Heavy duty steel body
•
Roller
-
150mm
•
Having duct, hose at lower hood to extract dust
•
Upper roller bearing with vertical and tilting adjustment for sander belt alignment
•
Be
lt size 80”x4”
35.
MCPTR035
ANVIL
•
Tip to tip length
-
15
-
20”
•
Height
-
5
-
7”
•
Face width
-
4
-
5”
•
Base width
-
5
-
7’
•
25 KGS, Mild steel
36.
MCPTR036
SELF
LEVELING
LASER WITH
STAND
•
Working range: up to 30
-
35ft
•
Leveling accuracy: +/
-
2/4
-
inches
•
Line accuracy: +/
-
3/32
-
in end to
end at 20’ perpendicular distance
•
Laser diode: two 635
-
670mm
•
Laser class: class 2M
•
Batteries: 3 “AA” alkaline batteries
•
Battery life: upto 50
-
60 hours of intermittent use
37.
MCPTR037
Bed side pedo
cycle
Should provide aerobic benefit of cycling to a bed ri
dden patient or those who cannot sit on a
static cycle.
Adjustable leg length & resistance level.
Self powered, smooth operation.
Straps to secure feet in pedals.
Digital/ LCD display of basic parameter showing speed, distance, time, calories, no. o
f cycle etc.
38.
MCPTR038
Kinesio sports
tape
Hypo allergic cotton fabric, latex free.
High adhesive quality (heat activated)
Should be ideal for sports soft tissue injury taping.
Water resistant should not get harden with change in temperature.
Each roll
-
width 2” length 5 meters.
Elasticity not less than 140%.
39.
MCPTR039
Therapy putty
(clay)
Should be ideal for hand function training.
Non oily, non toxic
Resistance category super soft to extra firm with colour code (at least 4
-
5 levels of resistance)
Should not fragment, separate, stain or stick to the skin
4
-
5 levels of resistance pack, weight 500gms each pack (2
-
2.5 kg)
40.
MCPTR040
Quadriceps
board
Made up of polished teakwood base with slots.
Two movable board with a hinge to allow quadriceps muscl
e exercise at various knee flexion
angle.
Base should be stable.
Smooth Edges.
Should be of ideal measurement for an adult patient.
41.
MCPTR041
Hand grip
exercise
Chrome plate frame rectangular in shape
Chrome plate springs
frame
Spring not less than 5 i
n numbers. Should be detachable to offer various level of resistance for
grip strengthening.
Wooden base for stability.
42.
MCPTR042
Power web
Rubber
webbing grip
exerciser
For finger hand grip & thumb exercise.
At least 3 level of different resistance.
1
4” ring diameter maximum.
43.
MCPTR043
Stability
trainer foam
Oval shape special stability trainer foam.
Should offer at least two or three levels of firmness.
Should provide progressive balance training for adult as well as pediatric age group
44.
MCPTR044
T
rampoline
Heavy duty frame and springs.
Minimum 40” diameter, 9” height
Vinyl reinforced stitching and commercial grade trampoline fabric
Should be ideal for pediatric use
Provision of hand rail for added stability
Max body weight allowed not less than
50kgs.
45.
MCPTR045
Exercise mat
Light weight high density foam with durable nylon fabric covering and reinforced stitching.
Reinforced handle at side for easy shifting
Peel & tear resistant, impermeable for fluid, crack resistant
Should allow easy cleanin
g
Mat size 120cm x 190cm x 10 cm
46.
MCPTR046
Exercise roll
(bolster)
Made up of high density foams with a solid plastic core covered with nylon fabric.
Peel & tear resistant
Impermeable for fluid
Crack resistant
Should allow easy cleaning
Stand on one e
nd & other end should must have provision for handle for easy shifting
Rack must for compact storage
Should be ideal for gross motor function, pediatric therapy & mat activity like rolling rocking.
Measurement As Follows
–
DIAMETER
LENGTH
15cm
6
0cm
20
90
25
90
30
90
47.
MCPTR047
Exercise
wedges
Made up of high density foams covered with nylon fabric.
Peel & tear resistant
Impermeable for fluid
Crack resistant
Should allow easy cleaning
Rack must for compact storage
Should be ideal for gr
oss motor function, pediatric therapy & mat activity.
Measurement as follows
–
WEDGE ELEVATION
BASE
15CM
60X70CM
20CM
60X70CM
25CM
60X70CM
30CM
60X70CM
48.
MCPTR048
Venile coated
iron
dumbbells
Should must be provided in pairs
Vinyl coated cast iro
n dumbbells
Thick smooth comfortable grip
Storage rack or trolley must.
Weight category (each in pairs) 500 gms, 1kg, 1.5kgs, 2kgs, 2.5kgs, 3kgs, 3.5kg, 4kg, 5kg
49.
MCPTR049
Soft ball
weight
Soft vinyl ball shaped weights
Should must be provided in pairs
Colour coded for different weights
Storage rack or trolley must.
Weight category (each in pairs) 500gms, 1kg, 1.5kgs, 2kgs, 2.5kgs, 3kgs.
50.
MCPTR050
Physio gym
ball
1.
Inflatable exercise balls
2.
Anti burst quality
3.
Non slip ribbed vinyl surface for extra
grip
4.
Max weight tolerance 200 kgs or more
5.
Storage rack or trolley must
6.
Sizes 45,55,65,75,85,95 cm
51.
MCPTR051
Peanut
shaped physio
gym ball.
1.
Should move in one direction only
2.
Should be more stable than conventional rounded gym ball
3.
Anti burst quality
4.
Non slip, ribbed vinyl surface for extra grip
5.
Max weight tolerance 300kgs or more
6.
Should be provided with a storage rack
7.
Sizes 85,100,120 cm
52.
MCPTR052
Continuous
passive
movement
lower limb
1.
Microprocessor controlled electronic circuit board.
2.
Knee flexio
n & extension 0°
-
130°
3.
Hip flexion & extension 0°
-
90°
4.
Ankle range 20°
-
0°
-
40°.
5.
Flexion extension angle selection
–
one degree / selectable
6.
Treatment time
–
1
-
60 min
7.
Max patient weight allowed not less than 150 kgs
8.
Power source 24V adaptor
9.
Speed
should be adjustable
10.
Smooth operation
11.
Wired remote control for patient as standard accessory
12.
Adjustable calf & thigh length range
13.
Digital / LCD display showing treatment time, joint angle flexion & extension, speed.
14.
Emergency stop switch
15.
Light weight &
sleek design for easy transportation
16.
Cushioned surface with limb securing straps.
53.
MCPTR053
Rollator
walker junior
size
1.
Light weight walker
2.
Steel tubing frame
3.
Front wheels and back rubber tip ferrules.
4.
Adjustable handle bar length
5.
Height adjustment
24 to 30’’
54.
MCPTR054
Static bicycle
junior size
1.
Should be suitable for 5 to 15 year of age cycling
2.
Stable base
3.
Adjustable height, leg length
4.
Should offer various level of resistance
5.
Basic parameters like speed, distance, calories to be displayed in LC
D display.
6.
Straps to secure feet with the pedals.
55.
MCPTR055
Paediatric
walking
1.
Parallel bars with height (21
-
30”) and width (13
-
20”) adjustment
2.
Length 3 meters
parellal bar
3.
Wooden base platform for stable mounting
4.
Incline ends
5.
Hand rails of steel tubi
ng chrome plated
56.
MCPTR056
Treatment
table
1.
Made up of hard wood in natural finish with soft padding on top with Rexene cover
2.
Measurement 6ft x 3 ft x 3 ft
3.
One storage drawer underneath the top.
4.
Mounted on sturdily built hardwood
57.
MCPTR057
Motorized
treadmill
1.
Should be Ideal for both medical as well as sports fitness purpose.
2.
Adjustable ergonomic front and side bars.
3.
Easy to operate control panel display should be easily visible with LCD.
4.
Low mounting height
5.
Emergency stop button provision
6.
Programma
ble, in built TMT protocols
7.
Power full AC motor
–
2.1 Hp to 4 Hp
8.
Supply voltage
–
230 V +
-
10%, 50Hz
9.
Driving force
–
Frequency control rotator field electromotor
10.
Motor capacity
–
1500w to 1800w
11.
Max power consumption 10A
12.
Min
-
max speed 0.5 to 20 km/h
13.
Bel
t area
–
not less than 50x150cm
14.
Max client weight
–
not less than 130 kgs
15.
Inclination 0
-
25%
58.
MCPTR058
Heart rate
monitor
1.
Automatic calculation of training zone intensity with available and visual alarm
2.
Calorie expenditure with % of fat burn calorie
3.
99 la
ps /spilt stop watch with 1/100 sec resolution.
4.
Flexible display unit
5.
Provision for chest straps and wrist watch type sensor
59.
MCPTR059
Aesthesiomet
er
Monofilament
testing
apparatus
1.
Cutaneous sensation evaluation by log force calculation
2.
Should must cons
ist of glass fiber nylon monofilaments each precisely calibrated and of equal
length (not less than 10 in numbers from 1.65mm to 6.65mm thickness)
3.
Log force calculation and complete instruction manual should must be available
4.
Small & portable in size with
a protective case.
60.
MCPTR060
Pin wheel
1.
Stainless steel pin wheel for evaluation of cutaneous sensation along dermatome
2.
Length not less than 6”
3.
Smooth running pin wheel
4.
Pins should be of equal length with blunt end
61.
MCPTR061
Two point
discriminator
1.
S
tainless steel
2.
Compact design
3.
Straight, blunt tips
4.
Should allow precise measurement
62.
MCPTR062
Tuning fork
1.
For evaluation of vibration sense
2.
Minimum 30 cycle fork for low end testing
3.
Maximum 256 cycle for high end testing
63.
MCPTR063
Skin fold
callip
er
1.
For measurement of subcutaneous tissue fat
2.
Spring loaded arm for reproducible pinch
3.
Reading upto 60mm
4.
Light weight sturdy design
5.
Should must be provided with user manual
64.
MCPTR064
Stop watch
1.
Analog type
2.
Clear visibility
3.
Should provide information
about seconds, minutes, hrs.
65.
MCPTR065
Hydraulic
hand held
dynamometer
kit
1.
For evaluation of routine grip strength
2.
Analog type numerical display
3.
Should allow display of isometric grip strength from 0
-
25kgs
4.
Peak hold indicator needle
5.
Adjustment for gr
ip position
6.
Provision for pinch gauge 0
-
20 kg
66.
MCPTR066
Pelvic
inclinometer
1.
Should be ideal for pelvic tilt measurement
2.
Should measure distance + angle between two caliper ends
3.
Marks in cm or inches
4.
Chrome Plated Metallic Or Fiber Body Design
67.
MCPTR067
Inclinometer
1. Fiber body
2. Should be ideal for spinal range of motion measurement
3. Reliable and reproducible results
68.
MCPTR068
Artificial
anatomical
model of
following
joints
1. Should be ideal for demonstration/ teaching/patie
nt education purpose
2. Made up of fiber glass molded on base of wooden.
3. Should be maneuverable.
4. Required articulated joint models are as follows
1.
Right side articulated hip
2.
Right side articulated shoulder
3.
Right side articulated knee
4.
Right side artic
ulated elbow
5.
Right side articulated ankle
6.
Right side articulated wrist
7.
Right side articulated foot
8.
Right side articulated hand.
9.
Articulated whole spine
10.
Articulated cervical spine
11.
Articulated lumbo
-
sacral spine
12.
Articulated pelvis.
69.
MCPTR069
Ultra sound
the
rapy unit
1.
Dual head frequency treatment for 1 MHz.
2.
Mode : Continuous & Pulsed
3.
Output
–
15 Watts/ Power intensity
–
up to 3 Watts/cm2, Power source 220V AC / 50Hz
4.
Digital Display
5.
Timer
–
0
-
30 minutes with auto off & buzzer
70.
MCPTR070
Interferential
thera
py unit
1.
Output: 2 separate output channels I & II
2.
Output :0
-
90 MA
(ift)
3.
Output frequency :
channel I 4000 Hz
–
4250Hz depending on the base & spectrum control
channel II 4000 (constant)
4.
Selection is also provided to avail 2000 Hz as basis frequency.
5.
Spectrum 0Hz
-
150Hz
6.
Interference spectrum indicator
–
required on the front panel.
7.
Vector scanning
–
45 & 90 degrees,
8.
Mains supply
–
230 v ac./ 50Hz, Power consumption
–
50 watts
71.
MCPTR071
Tens unit
(transcutaneo
us electrical
nerve
stimulation)
1.
4 Channel
TENS with 8 electrodes
2.
Pulse width
-
50 microsec to 300 millisec
3.
Frequency
-
2 Hz to 600 Hz
4.
Intensity
-
0
-
60 mA
5.
Output voltage
–
0 to 50 Volts
72.
MCPTR072
Short wave
diathermy
(500 w)
1.
Continuous mode / pad electrode
2.
Input : 100
-
240 Volt AC,
3.
Frequency: 27.
12 MHz
4.
HF output: 200
-
500 W
5.
Treatment Time: 1
-
30 minutes with automatic shut off & buzzer
73.
MCMJ073
Automated
Blood Culture
Cystem
Fluorescent base alert system
74.
MCMJ074
Electronic Ph
Meter
Digital display
75.
MCMJ075
Research
Microscope
Binocular with (
5mp) Attachment to LCD Monitor
76.
MCMJ076
Diagnostic
Microscope
(Olympus)
Binocular Light Microscope
77.
MCMJ077
Electronic
Weighing
Machine
Able to weith o.5
-
20grams
78.
MCMJ078
Electronic
Centrifuge
Must have a speed regulator
79.
MCMJ079
Themo cycler
Autom
ated Programmable
80.
MCMJ080
Gel
Documentatio
n System
Standard System
81.
MCMJ081
Refrigerated
Centrifuge
For DNA
82.
MCDJ082
IOPA Dental
X
-
ray
Machine
Dental X
-
ray Should be capable of exposures tmj fronal maxillary sinus. It should be output of 55KV
to 85
KV, 10ma Generator should be 2.9V Expousure time 15 Secound or more Power requirement
Single Phase, 230 Volts, 50 Az, less than 15Amps.
83.
MCFJ083
Firearm
Weapons
Prototype
Pistol
Revolver
Airgun
Rifle
84.
MCFJ084
SLR digital
Camera with
access Ories
Expos
ure System
• Metering : Switchable: 40 segment honeycomb pattern; Center Weighted, Spot
• Exposure Compensation : ±3.0 EV (in 0.3EV, 0.5EV steps)
• Exposure Settings : Auto, Program Auto (P, with Program Shift), Shutter Priority (S), Aperture Prior
85.
MCB
J085
Refrigerated
Centrifuge (
-
20c) (20000
rpm)
• Max speed : 18,000 rpm.;
• Max rcf: 30,076 xg
• Max Volume: 1000 ml ( 4 x 250 ml)
• Temperature: 20 to Ambient, CFC free refrigeration
• Timer : Preselection of time up to 9 hrs. 59 min or continuous
•
Drive System : Maintenance Free, noiseless, bru
86.
MCBJ086
Spectrophoto
meter
UV visibledouble beam with multiple cuvette holders with attached PC, inbuilt stabilizer, two sets
of quartz cuvette, digital display with software control system .
Can perform k
inetic analysis
87.
MCBJ087
Spectro
Flourometer
PC controlled system with measurement modes for fluorescence, phosphorescence,
chemiluminescence and bioluminescence.
All reflective optical system with quartz over coated optics, Schwarzchild source optics fo
r increased
throughput.
Source: Xenon pulse la
88.
MCBJ088
Ultracenterifu
ge
Specification for Preparative Floor Model Ultracentrifuge equipped with a HEPA filter and necessary
rotors for Biosafety Lab
1. The ultracentrifuge should be capable of going to spe
eds of 1,00,000 RPM and forces up to
approximately 8,02,00 x g and should
89.
MCBJ089
Fully
Autoanayzer
SPECIFICATIONS FOR AUTOMATED BIOCHEMISTRY ANALYZER:
1. System: Fully automated, random access, floor model biochemistry analyzer with a minimum
throughp
ut of 800tests/hour , 400tests photometry/hr, 400ISE/hr
2. Reagents handling:
a. Accommodate a minimum
90.
MCBJ090
Automated
Electrophores
is
SPECIFICATIONS FOR FULLY AUTOMATED ELECTROPHORESIS SYSTEM:
1. The system should be fully automated electrophoresis
system based on Capillary electrophoresis
with 2 simultaneous migrations with complete walk away technology including migration and
quantita
91.
MCBJ091
Fully
Automated
Chemilumines
SPECIFICATION OF CHEMI
-
LUMINESCENCE
cence
Random Access Chemi
-
luminescence I
mmuno Assay Analyzer
1. System should be based on technology of paramagnetic particles with dio oxetebce phosphtas.
2. Atlast 22 assays from one sample.
3. Automated inventory managemen
92.
MCBJ092
Atomic
Absorption
Spectrop
hotomete
Fully controlled by PC,
Automatic wavelength Set
-
up, Automatic Slit switching, Automatic Lamp
current and gain set
-
up within 40 seconds. Auto switching and control 6 lamps on rotating turret,
Automatic flame ignition, automatic flow control for gases and
AUTOSAMPLER FOR FLAME
(OPTIONAL)
Up to 60 ea of 5ml vials, carousel type
Max. injection volume: 4ml
Accuracy :
-
2~3%
PRE REQUITES FOR AAS :
-
Description of goods/Qty
1. Two stage cylinder regulator brass chromplated body with S.S. Diap
93.
MCBJ093
Upright
Mic
roscope
(Complete
1.
General Specifications
System should consist of upright microscope with epi
-
fluorescent
with
accessories)
attachment, image acquisition unit (digital camera) and workstation
computer with data collection & processing software modules fo
r
• Bright field or Fluorescent
Karyotype Using Species Templates
For CGH, RxFISH and M
-
FISH cells the template must be attached before the cells are captured. For
bright field, fluorescent and standard FISH cells the template is attached as part of the
karyotyping
process. A classifie
FISH Software 8.
9. Other applications to be supported for upgradation 1. Multicolor/Multistain FISH (M
-
FISH)
2. Comparative Genomic Hybridization (CGH)
3. Color karyotyping
-
capability of karyotyping metaphase with FISH pro
bes; color caryotyping in
DAPI
94.
MCSKJ094
Phototherapy
Unit (U V A &
UVB COMBO)
a) Different combinations (UVA & NBUVA) can be provided.
b) Tubes from Philips Holland.
c) The Unit provided with imported mirror type reflectors.
d) Cabinet made of high qu
ality steel and powder coated.
e) Special UV chokes for maximum life for the tubes
95.
MCEJ095
Nasal & sinus
endoscopes
with CCD
camera
computer,
LED coldight
source, fibre
optic cable.
LED monitor
beam spliter
0,30,45,70 degree one ngid hopkins telescope 4
mm 18cm wide angle autocavable
96.
MCEJ096
Micromotor
drill with
handplace
MM drill with 40000 rpm. Angled hand piece conrolebox foot controle
97.
MCEJ097
Burrs set of 5
each
(imported) (a)
cutting
tonguston
carbide (b)
Diamond (c)
polishing
Cutting burrs
-
0.6mm to 6mm Set of 5
-
two set, diamondburrs
-
0.6 to 6mm set of five (two set)
polishing burrs (Size 6mm, 1mm, 2mm, 4mm, 6mm) tungustone carbide Length 70mm
98.
MCEJ098
Otoscope
-
Beta 200
Fibre opticullumination with seigle attachment.
99.
MCOPJ099
Operati
ng
Microscope
1. Unperellaled depth perception
2. X
-
Y coupling
3. Brilliant electronic.
4. fine focus adjustment and zoom through fooot switch
5. Effortless balancing
6. lllumination through fibre optic cable
100.
MCOPJ100
ND
-
yag laser
Nidek
1064mm Photodisr
uption
101.
MCOPJ101
Schiotz
Tonometer
Imported
102.
MCOPJ102
Fundus
Camera
(Zeiss)
3 in 1 multifunctional retinal camera lower flesh intencity
easu to use
continuous shooting function
auto focus and auto shoot
103.
MCORJ103
Mobile C
-
RAM (Image
Intenshifier
T.V
. System)
Technical Specifications
Generator Rating High Fequency
Frequency
-
40Khz
Power
-
3.5Kw 6.3 Kw for Rotating Anode
Radiography Mode
Kvp Output 40 to 100 Kvp 40 to 110 Kvp for Rotating Anode
mA Output
-
upto 50mA upto 80mA for Rotating Anode
mAs
Range
–
X
-
Ray tube
-
Focal Spot Stationary Anode
-
0.6/1.0mm 0.3/0.6mm for Rotating Anode
Optional
-
Line frequency models
Image Intensifier 9" Triple field, high gain, low dose image intensifier tube (optional 6" single / Due
field)
Camera
-
High sen
sitivity,
104.
MCORJ104
DHS & DCS
Instrument
Set with
Implants
Alu Case, blue, Yellow Lid, perforated, without contents
Upper Tray for Instrumenbts for 301.320, without Contents
Lower Tray for Instruments for 301.320, without Contents
DHS/ DCS Threaded Guid
e Wire, 2.5mm dia., L 230/5mm
DHS Angled Guide 135
DHS Angled
105.
MCORJ105
Digital
Pneumatic
Max pressure: 600 mmHg
Tourniquet
Voltage: AC 100
-
240V ~ 50/60Hz
Power consumption: 50W
Noise dB: below 60 dB
Time range: 5~180 min
Compressor weight: 5.6 kg
Compre
ssor dimension: 225(W) x 185(D) x 240 (H) mm
Built in lithium battery: life time 12~72 hours System fe
106.
MCORJ106
Surgical,
Diathermy
(bipolar)
§ The machine should be Microprocessor controlled with maximum output power of 400 W at 500
ohms
§ The modes of
operating should be monopolar and bipolar
§ Monoplar cut and coagulation. With coagulation having two modes : Contact and spray
§ Monopolar cu
107.
MCAJ107
Microscope
Student Type with Objectives
-
Scanning, Lowpower and Highpower, No Oil Immersion Lens, N
o
Built in Light Source
108.
MCAJ108
Microtone
Rotary with
Disposable
Blades
Rotary Microtone with Detachable Blades
109.
MCMDJ109
Video Upper
G.I.
Endoscope
specification gastrointestinal videoscope
Optical System Field of View : 145°
Direction of View
: 0° Forward Viewing
Depth of field : 3
-
100 mm
Distal End Outer : diameter
Specifications
Illumination : Lamp halogen or LED source
Switching of lamps : Manu
al.
Power supply : Voltage : PAL: 220
-
240V AC. NTSC: 100
-
120 V AC Frequency : 50/60 Hz
Size : Dimensions : 295(W) x
110.
MCMDJ110
Video
Colomoscope
Specifications
Illumination : Lamp halogen or LED source
Switching of lamps : Manual.
Power supply : Voltage : PAL: 220
-
240V AC. NTSC: 100
-
120 V AC Frequency : 50/60 Hz
Size : Dimensions : 295(W) x
Specifications
Illumination : Lamp halogen or LED source
Switching of lamps : Manual.
Power supply : Voltage : PAL: 220
-
240V AC. NTSC: 100
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Preparing document for printing…
0%
Σχόλια 0
Συνδεθείτε για να κοινοποιήσετε σχόλιο