Paper C12-1, A 22nm Dynamically Adaptive Clock Distribution for ...

stingymilitaryΗλεκτρονική - Συσκευές

27 Νοε 2013 (πριν από 3 χρόνια και 8 μήνες)

78 εμφανίσεις

80
V = 1.0V
Conventional Clock Distribution
CC
Adaptive Clock Distribution
60
TP = 14% 
V = 0.8V
CC
Energy = 3% 
V = 0.6V
CC
TP = 18% 
40
Energy = 5% 
TP = 31% 
Energy = 15% 
20
Functional Test with 10% V Droop
CC
2-Cycle Response Time for Adaptive Clock Distribution
0
0 200 400 600 800 1000
Throughput (MIPS)
Energy per Cycle (pJ)