City of Seattle

spotpullΛογισμικό & κατασκευή λογ/κού

2 Νοε 2013 (πριν από 3 χρόνια και 10 μήνες)

84 εμφανίσεις


City of Seattle


Department of Executive Administration



Fred Podesta, Director


Gregor
y J. Nickels, Mayor


Purchasing and Contracting Services Division

700 Fifth Ave., Suite 4112, Post Office Box
94687
, Seattle, Washington 98124
-
4687

Purchasing: Tel: (206)
684
-
0444

TDD: (206) 615
-
0476 Fax: (206)
233
-
5155

Contracting: Tel: (206)
684
-
043
0

TDD: (206) 615
-
0476 Fax: (206)
684
-
8286


Website:
www.cityofseattle.net/contract/








June 4, 2008


TO:



All Potential
Bidders





FROM:



Pam Tokunaga,
Principal

Buyer




City of Seattle Purchasing




Phone 206
-
233
-
7114; Fax 206
-
233
-
5155




Email Address:
pam.tokunaga@seattle.gov



REFEREN
CE:


Invitation to Bid #FFD
-
733, 46,000 GVWR Tiltdeck Trailer


ADDENDUM #1


Reference is made to
Invitation to Bid
#FFD
-
733

dated
5/13/08

scheduled to be due at
2
:00 PM,
6/10/08. The following questions and answers shall be made part of this Invitation to

Bid.



Q
uestion
:
Attachment #1,
Trailer Platform, item 2, page 3: Is a 12,000 pound capacity electric /
hydraulic jack acceptable?

A
nswer
: Yes, it exceeds the minimum specification.


Q
uestion
:
Attachment #1,
Trailer Platform, item 8, page 3: Is electric

/ hydraulic lift and lower
assist acceptable?

A
nswer
: Yes, it exceeds the minimum specification.


Q
uestion
:
Attachment #1,
Decking, item 1, page 4: Please explain what 2X means.

A
nswer
:

The 2X means “two by” as in 2x6 or 2x8.


Q
uestion
:
Attachment #1,
De
cking, item 9, page 4: Is an air locking system as well as a pin
acceptable?

A
nswer
: Yes, it exceeds the minimum specification.


Q
uestion
:
Attachment #1,
Trailer Material, item 1, page 5: Is 10” “H” beam acceptable?

A
nswer
: Yes


Q
uestion
:
Attachment #1
Tr
ailer Material, item 2, page 5: Is 4” “I” beam acceptable?

A
nswer
: Yes


Q
uestion
:
Attachment #1,
Trailer Material, item 3, page 5: We do not use longitudinals. We
supply additional strength to our perimeter rails (10”) and our cross members (4”). Is th
is
acceptable?

A
nswer
: Yes


Page
2

of
2

Q
uestion
:
Attachment #1,
Trailer Material, item 4, page 5: Is 10” formed channel acceptable?

A
nswer
: Yes


Q
uestion
:
Attachment #1,
Electrical Requirements, General, item 5, page 6: A clarification was
requested on the need for

conduit on all wiring.

A
nswer
: The manufacturer is required to protect the wiring. Bare unprotected wiring will get
snagged and damaged over time. As long as the wiring is secured and protected it is acceptable.
Protected means behind channel, in cond
uit or tucked up where it can not be snagged.


Q
uestion
:
Attachment #1,
Electrical Requirements, Dealer Installed Wiring, item 1, page 6: We
would like to supply solid core wiring and Truck Lite sealed system. Is this acceptable?

A
nswer
: No. Please not
e this section is for dealer installed wiring. Any wiring added by the
dealer must meet specification. The intent is to keep the dealer from installing wiring that is
inferior to the manufacturer’s standards. Solid core wiring installed by either the ma
nufacturer or
dealer is not acceptable on mobile equipment. The city would expect the manufacturer to use
SAE stranded wire as a minimum. Solid core wire is intended for stationary applications and will
break rather then flex on mobile equipment.


Q
ues
tion
:

Attachment #1,
Paint, item 1, page 7: We use Zenthane Plus polyurethane paint by
Hentzen Coatings. Is this acceptable?

A
nswer
:

Yes.


Note:
Attachment #1,
Options, page 9
: Please quote all available options for this size trailer
including a 24’ dec
k with stationary front platform.



The due date for this
Invitation to Bid

remains unchanged at
2
:00 PM,
6/10
/08.


In all other respects, the
Invitation to Bid

remains unchanged.