ANECHOIC CHAMBER





Military Institute of Armament Technology has been involved for many years into microwave technology
and electromagnetic compatibility. It was more than 20 years ago
in
the Institute where the first
microwave
a
nechoic chamber was
d
esigned in

the country

to test electronic equipment and
components, microwave absorbers and camouflage nets and to develop antennas, electronic
instruments, microwave radomes and absorbers, etc.


After the upgrading of anechoic chamber launched in

2008

an
d funded both by Institute’s own
resources and the donation of Ministry of Science and Higher Education testing and measurement
capacities of the laboratory have increased as a lot of modern instruments was used.

The chamber was completed in

2009

and meet
ing of below listed standards was certified by tests of
Rainford EMC Systems
and

Accredited Testing Laboratory (N
o

32) Austrian Research Cent
re
s
:



a)

EN50147
-
1, MIL
-
STD
-
285, NSA 65
-
5
for efficiency of screening
:



-

min. 100 dB
for electric fields on

30 MHz
-

18 GHz

band
;



-

min. 80 dB
for electric fields on

18 GHz
-

40 GHz

band
;



-

min. 80 dB
for magnetic fields at

0,01 MHz;



-

min. 100 dB
for magnetic fields at
: 0,1 MHz, 1 MHz, 10 MHz;



b)

EN50147
-
2, ANSI C63.4
and
CISPR
-
16
-
1
-
4:2008
-
01
for
standardised attenuation in the
measurement zone
:


-

measurement zone with diameter

1,5 m
and height

2 m

at distance

3 m;



-

NSA
within the measurement zone better than

±3 dB
on

30 MHz
-

200MHz

band

and

±1,5 dB
on

200MHz
-

1 GHz

band
;



-

sVSWR w strefie

pomiarowej: ≤ 4,2 dB w przedziale częstotliwości


od 1 GHz do 6

GHz i ≤ 3 dB w przedziale częstotliwości od 6GHz do 18 GHz;



-

Transmission Loss ≤ ±3 dB dla częstotliwości od 18GHz do 40GHz;



c)

EN 61000
-
4
-
3
within the measurement
zone at the distance to

3 m,


for

75%
of

16
measurement points
,
and homogeneity
:



-

≤ 5,5 dB
on
26 MHz
-

80 MHz

band
;



-

≤ 6 dB
on

80 MHz
-

1 GHz

band
;



-

≤ 4 dB
on

1 GHz
-

4,2 GHz

band
;



-

≤ 4,5 dB
on

4,2 GHz
-

18 GHz

band
.


The laboratory
has such

certificates as No AB171 from the Polish Centre of Accreditation, No
5/MON/2008 from the Minister of National Defence and

N
o

PE
-
op
-
pe
-
4697/97

from the Minister of
Environment Protection. Under the upgrading project partly donated by the Ministry of Higher

Education
following examples of instrumentation increased measurement capacities of the laboratory in

2009:


-

software governing measurements of resistance and emissivity
;


-

antenna measurement system
:
turning table with the controller’s angular accur
acy
0,02
0

and
software
;


-

power meter for measurements of pulse electromagnetic fields starting from

50 ns
on

50MHz
-

40GHz

band
;


-

electric and magnetic field analyser operating on

5Hz
-

100kHz

band
;


-

EMC measurement receiver with spectrum analyse
r on

20Hz
-

40 GHz

band
;


-

vector signal generator operating on

100 kHz
-

6GHz
band with software generating such
standards as
: GPS (Global

Positioning
System), GSM (
European mobile phone

system),
EDGE (
data transmission in mobile phone systems
), NADC (
USA

mobile phone system
), PDC
(
Japanese mobile phone system
), PHS (
mobile phone system existing in some Asian
countries
), DECT (
home wireless phones
), TETRA (
radio communication system for public
security services
). Generator
can be used to calibrate posit
ioning systems and connected to
an amplifier provides testing of mutual interaction between instruments operating at above
standards and their resistance against interference
;


-

other accessories
:
artificial mains
,
programmable optical multiplier
,
cables
, anten
nas
,
positioning systems etc
.


In the future the laboratory will be fitted with
:


-

system
for testing equipment’s resistance against electromagnetic radiation on

10 kHz
-

40GHz

band
. System
will provide the homogeneous field at the distance

1 m
fr
om antenna with intensity

(
without modulation
):

minimum: 20 V/m @ 10 kHz ÷ 2 MHz;


minimum: 50 V/m @ 2 MHz ÷ 26 MHz;


minimum: 60 V/m @ 26 MHz ÷ 18 GHz;


minimum: 200V/m @ 18 GHz ÷ 40 GHz;


And at the distance

3 m
with modulation

AM 80% minimum 18 V
/m;


-

vector analyser
PNAX
on

10MHz
-

110GHz

band

(
with a possibility for increasing to

500GHz)
to measure components of the scattering matrix

[S]:

-

measurements of reflection

(S
11

, S
22
):

attenuation of reflection
,
attenuation inserted
,
VSR
,
coeffici
ent of reflection
, impedanc
e
;

-

measurements of transmission

(S
21

, S
12
):

attenuation inserted
,
coefficient of
transmission
,
amplification
/
attenuation
,
group delay
,
deflection from the phase line
,
electric delay
.



Possessing a modern testing
-
measurement s
ystem with experienced personnel and access to
testing ranges the Laboratory offers following services
:


1.
Co
-
operation with university and industry centres to
:

Use testing
-
measurement equipment of the laboratory for planned research
-
development
projects
;

Use testing
-
measurement equipment of the laboratory for didactics processes
;


2.
Arrangement and execution of tests for equipment and electronic systems including
accreditation tests
.


3.
Technical support and measurements.


4.
Technical and design work in domain of microwave technology and radar and electronic
warfare systems
.