INFOR WAREHOUSE MOBILITY FRONTEND UPGRADE GUIDE FOR SYTELINE

illinoiseggoΛογισμικό & κατασκευή λογ/κού

28 Οκτ 2013 (πριν από 3 χρόνια και 5 μήνες)

349 εμφανίσεις





Warehouse Mobility

Front End Upgrade
Guide for
Syteline



Copyright © 2012 Infor. All rights reserved. The word and design marks set forth herein are trademarks and/or registered trad
emarks of Infor and/or related affiliates

and

subsidiaries. All other trademarks listed herein are the property of their respective owners. www.infor.com.



INFOR

WAREHOUSE
MOBILITY

FRONTEND

UPGRADE GUIDE

FOR

SYTELINE

ADC
Version

R3.01.14







Released: 6/2013

Rev: 6/27/2013






































2

Warehouse Mobility

Front End Upgrade Guide for
Syteline





1.
PRE
INSTALLATION STEPS




Take back up of the
following directories
.

o

c:
\
b2bar
\
syteline

o

c:
\
b2bar
\
development

o

c:
\
b2bar
\
production

o

c:
\
b2bar
\
jars


Note
:
If you have more than two environments take back up of those environments also.

This patch is applicable for the
customers who installed warehou
se mobility application R3.01
.
13
.


2
.
STEPS FOR UPGRADE




Stop the below services
.

o

Apache Tomcat

o

Bridgelogix B2BGendService

o

Bridgelogix Bridge2WorldService

o

BlxSytelineDevelopmentAdapterService

o

BlxSytelineProductionAdapterServi
ce1

o

BlxSytelineProductionAdapterService2



Unzip the file InforWarehouseMobility_
Syteline_R
3.
01
.
14
_
WMSR201306
.zip to a temporary
directory.




Copy the
ibctransaction.jar

file from the extracted
Infor
WarehouseMobility_Syteline
_
R3_01_14

folder to
C
:
\

b2bar
\
jars folder
.




Remove the file version.txt from the C:
\
b2bar
\
documents folder.




Remove the ibcpatch.jar from C:
\
b2bar
\
development
\
dcjava folder. If this file is present in the
dcjava folder.




Remove the ibcpatch.jar pa
th from adc_settings.xml file. T
he path
text
should be removed after
the “ibccustomertransaction.jar” path and before the “ibctransaction.jar”.

Below is
a
example classpath after removing the ibcpatch.jar to adc_setting.xml file.


<config_param id='scanner_program'>&j vm;
-
classpath
&base
dir;/development/dcjava/ibccustomertransaction.jar
;&
basedir;/jars/ibctransaction.jar;&base
dir;/jars/ibcsyteline.jar;&basedir;/jars/ibcframework.jar;&basedir;/jars/ibcxmltypes.jar
-
Djava.util.logging.config.fil e=&basedir;/config/logging.properties
-
Djava.ut
il.logging.FileHandler.limit=262144000
-
Djava.util.logging.FileHandl er.count=2
blx.framework.application.ADCInterface &basedir; &basedir;/config/adc_settings.xml
</config_param>




Copy the files release.jsp and
NavigationFrameIndex
.jsp from the adcadmin fol
der from
extracted

InforWarehouseMobility_Syteline_
R3_01_14

folder to
C:
\
b2bar
\
common
\
adcadmin

folder.


3

Warehouse Mobility

Front End Upgrade Guide for
Syteline






Copy the file
commons
-
io
-
2.4
.jar from the adcadmin folder from extracted
InforWarehouseMobility_Syteline_
R3_01_14

folder to
C:
\
b2bar
\
common
\
adcadmin
\
WEB
-
INF
\
lib

folder.




Copy the

all the files from the trans folder
from the extracted
Infor
WarehouseMobility_
Syteline
_
R3_01_14

folder to C
:
\
b2bar
\
syteline
\
trans

folder
.




Copy all the files from the messages folder from the extracted
InforWarehouseMobility_Syte
line_
R3_01_14

folder to C:
\
b2bar
\
syteline
\
data
\
messages
\
english
folder.




Copy all the files from the labels folder from the extracted
InforWarehouseMobility_Syteline_
R3_01_14

folder to C:
\
b2bar
\
syteline
\
data
\
labels
\
english
folder.





Compile the
labels and
messages from the adcadmin page after starting
the services
.


Note
: Add the parameter file in the
development and
production environment. If you have more than
2 environments add the parameter file in those environments also.


3
.
ADDING ADDITIONAL PARAMETE
RS FOR THE
T
RANSACTIONS

Parameter files are located in c:
\
b2bar
\
development
\
data
\
params

and in
c:
\
b2bar
\
production
\
data
\
params
. Procedure to add additional parameters are listed according to the
transaction. Include them according to the transaction.



Clo
ckInOutTrans
.xml


Open the file x:
\
b2bar
\
development
\
params
\
Cl ockInOut Trans
.xml in a text editor such as notepad.


B
efore the tag
</param_value_list>

add

the following text:


<param_value id="process_real_time" label="Auto Post Jobs">no</param_value>



JobBookingTrans
.xml


Open the file x:
\
b2bar
\
development
\
params
\
JobBookingTrans
.xml in a text editor such as notepad.


B
efore the tag
</param_value_list>

add

the following text:


<param_value id="processRealTime" label="Auto Post Jobs">yes</param_value>

<
param_value id="ta_implemented" label="Time and Attendance Implemented">yes</param_value>



LunchInOutTrans
.xml



4

Warehouse Mobility

Front End Upgrade Guide for
Syteline



Open the file x:
\
b2bar
\
development
\
params
\
LunchInOutTrans
.xml in a text editor such as notepad.


B
efore the tag
</param_value_list>

add

the following text:


<param_value id="process_real_time" label="Auto Post Jobs">no</param_value>




TimeAttendanceTrans
.xml


Open the file x:
\
b2bar
\
development
\
params
\
TimeAttendanceTrans
.xml in a text editor such as
notepad.

B
efore the tag
</
param_value_list>

add

the following text:


<param_value id="process_real_time" label="Process Real Time">no</param_value>



Note
:

Add the additional parameters in th
e production environment. If you have more than 2
environments add the parameters in those
environments also.


4
.

STEPS
TO UPGRADE SYTELINE ADAPTER



Copy the files
BlxSyteLineDevelopmentAdapterService
.exe from temporary folder to
x:
\
b2bar
\
common
\
bin
\
devel opment




Make sure that
BlxSyteLineDevelopmentAdapterService
.exe,
BlxSyteLineDevelopmentAdap
terService
.
InstallLog

files are in the directory
x:
\
b2bar
\
common
\
bin
\
devel opment




St
art

the below services
.

o

Apache Tomcat

o

Bridgelogix B2BGendService

o

Bridgelogix Bridge2WorldService

o

BlxSytelineDevelopmentAdapterService

o

BlxSytelineProductionAdapterService1

o

B
lxSytelineProductionAdapterService2


5
.
STEPS
TO PERFORM FOR COMPILING LABELS AND
MESSAGES

Please follow these steps to compile labels/messages, if not the scanner will not open properly.




Open internet explorer and type the URL(
http://hostname:portnumber/adcadmi n

ex:
http://localhost:8080/adcadmin)




5

Warehouse Mobility

Front End Upgrade Guide for
Syteline







Login to development environment by providing the username and passwords
.








To compile the labels you click on the
System
Admin

tab then you will get submenus in that
click on
Maintain Labels

you will get the below page.



6

Warehouse Mobility

Front End Upgrade Guide for
Syteline








Then click on the
GO

Button. You will get the list of labels which we copied in the labels
directory. Click any one label in the labels list and press s
ave button.







Click on Save Button.



7

Warehouse Mobility

Front End Upgrade Guide for
Syteline








Repeat the above steps for the other languages which you want to use.





To
c
ompile the messages you click on the
System Admin

tab then you will get submenus in
that click on
Maintain Messages

you will get below p
age.






Then click on the
GO

Button. You will get the list of messages which we copied in the labels
directory. Click any one message in the message list and press save button.



8

Warehouse Mobility

Front End Upgrade Guide for
Syteline







Click on
s
ave button.






Repeat the above steps for the other languages
which you want to use.









9

Warehouse Mobility

Front End Upgrade Guide for
Syteline







6
.
STEPS TO ROLL BACK IN CASE OF FAILURE




Stop the below services
.

o

Apache Tomcat

o

Bridgelogix B2BGendService

o

Bridgelogix Bridge2WorldService

o

BlxSytelineDevelopmentAdapterService

o

BlxSytelineProductionAdapterService1

o

BlxSytelineProductionAdapterService2




Copy the following directories from backup
.

o

b2bar
\
syteline

o

b2bar
\
development

o

b2bar
\
production

o

b2bar
\
jars




St
art

the below services
.

o

Apache Tomcat

o

Bridgelogix B2BGendService

o

Bridgelogix Bridge2WorldService

o

BlxSytelineDevelopmentAdapterService

o

BlxSytelineProductionAdapterService1

o

BlxSytelineProductionAdapterService2